Solar radiation on domed roofs

被引:20
作者
Faghih, Ahmadreza K. [1 ]
Bahadori, Mehdi N. [1 ]
机构
[1] Sharif Univ Technol, Sch Mech Engn, Tehran, Iran
基金
美国国家科学基金会;
关键词
Domed roof; Solar radiation; Numerical method;
D O I
10.1016/j.enbuild.2009.07.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Solar radiation received and absorbed by four domed roofs was estimated and compared with that of a flat roof The domed roofs all had the same base areas, and equal to that of the flat roof. One of the roofs considered was the dome of the St. Peter's Church in Rome. Compared with the other roofs considered, this dome had a higher aspect ratio. It was found that all domed roofs received more solar radiation than the flat roof. Considering glazed tiles to cover a selected dome in Iran and the dome of the St. Peter's Church, it was found that the solar radiation absorbed by these roofs is reduced appreciably. In the case of the dome of St. Peter's Church, the amount of radiation absorbed was roughly equal to that absorbed by the comparable flat roof in the warm months. In the case of the glazed reference dome located in Yazd, Iran (a city with very high solar radiation), the radiation absorbed was less than that of flat roof at all times. In addition to aesthetics, this may be a reason for employing glazed tiles to cover the domes of all mosques, shrines, and other large buildings in Iran. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1238 / 1245
页数:8
相关论文