Performance of a triple-GEM detector for high rate charged particle triggering

被引:26
作者
Bencivenni, G
de Simone, P
Murtas, F
Lener, MP
Bonivento, W
Cardini, A
Deplano, C
Pinci, D
Raspino, D
机构
[1] Ist Nazl Fis Nucl, Lab Nazl Frascati, Frascati, Italy
[2] Univ Cagliari, Cagliari, Italy
关键词
GEM; tracking; aging; discharge;
D O I
10.1016/S0168-9002(02)01460-2
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report the results of a systematic study of the performance of 10 x 10 cm 2 triple-GEM detectors operated with several gas mixtures. In a previous paper, we pointed out that adding CF4 to the standard Ar/CO2 gas mixture allows to improve the time resolution of the detector from similar to10 ns down to similar to6 ns (r.m.s.). In this paper, we discuss the results obtained with CF4 and iSO-C4H10-based gas mixtures, during a beam test at the piM1 beam facility of the Paul Scherrer Institute (PSI). Preliminary results concerning the discharge probability of triple-GEM detector, when exposed to both high intensity pion/proton beam and alpha-particles from a radioactive source are presented. Gain measurements and aging tests, using a high intensity 5.9 keV X-ray tube, are eventually discussed. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:156 / 162
页数:7
相关论文
共 9 条
[1]   INFLUENCE OF GAS-MIXTURE AND CATHODE MATERIAL ON LIMITED STREAMER OPERATION [J].
BATTISTONI, G ;
CAMPANA, P ;
CHIARELLA, V ;
DENNI, U ;
DETTORREPIAZZOLI, B ;
IAROCCI, E ;
MANNOCCHI, G ;
NICOLETTI, G ;
PICCHI, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 217 (03) :433-439
[2]   A triple GEM detector with pad readout for high rate charged particle triggering [J].
Bencivenni, G ;
Felici, G ;
Murtas, F ;
Valente, P ;
Bonivento, W ;
Cardini, A ;
Lai, A ;
Pinci, D ;
Saitta, B ;
Bosio, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 488 (03) :493-502
[3]  
*LHCB MUON SYST TE, 2001, 2001010 CERN LHCC LH
[4]  
Raether H., 1964, Electron Avalanches and Breakdown in Gases
[5]   Absolute electron transfer efficiency of GEM [J].
Richter, C ;
Breskin, A ;
Chechik, R ;
Garty, G ;
Sharma, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3) :38-41
[7]  
Sauli F., 2000, CERNEP2000151
[8]  
TAYLOR FE, 1989, NUCL INSTRUM METH A, V289, P283
[9]   A HIGH-PERFORMANCE MULTICHANNEL PREAMPLIFIER ASIC [J].
YAREMA, RJ ;
ZIMMERMAN, T ;
WILLIAMS, W ;
BINKLEY, M ;
HUFFMAN, T ;
WAGNER, R .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1992, 39 (04) :742-746