Central Blood Pressure Estimation From Distal PPG Measurement Using Semiclassical Signal Analysis Features

被引:35
作者
Li, Peihao [1 ]
Laleg-Kirati, Taous-Meriem [1 ]
机构
[1] King Abdullah Univ Sci & Technol KAUST, Comp Elect & Math Sci & Engn Div, Thuwal 23955, Saudi Arabia
关键词
Estimation; Feature extraction; Eigenvalues and eigenfunctions; Databases; Blood pressure; Standards; Blood; Blood Pressure (BP); cuffless BP estimation; photoplethysmography (PPG); inappropriate PPG; Schrö dinger spectrum; SCSA feature extraction;
D O I
10.1109/ACCESS.2021.3065576
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Background and objective: Blood pressure (BP) is one of the crucial indicators that contains valuable medical information about cardiovascular activities. Developing photoplethysmography (PPG)-based cuffless BP estimation algorithms with enough robustness and accuracy is clinically useful in practice, due to its simplicity and noninvasiveness. In this paper, we have developed and tested two frameworks for arterial blood pressure (ABP) estimation at the central arteries using photoplethysmography and electrocardiogram. Methods: Supervised learning, as adapted by most studies regarding this topic, is introduced by comparing three machine learning algorithms. Features are extracted using semi-classical signal analysis (SCSA) tools. To further increase the accuracy of estimation, another BP estimation algorithm is presented. A single feed-forward neural network (FFNN) is utilized for BP regression with PPG features, which are extracted by SCSA and later used by FFNN as the network input. Both BP estimation algorithms perform robustly against MIMIC II database to guarantee statistical reliability. Results: We evaluated the performance against the Advancement of Medical Instrumentation (AAMI) and British Hypertension Society (BHS) standards, and we have compared the standard deviation (STD) of estimation error with current state of the arts. With the AAMI standard, the first method yields comparable performance against existing literature in the estimation of BP values. Regarding the BHS protocol, the second method achieves grade A in the estimation of BP values. Conclusion: We conclude that by using the PPG signal in combination with informative features from the Schrodinger's spectrum, the BP can be non-invasively estimated in a reliable and accurate way. Furthermore, the proposed frameworks could potentially enable applications of cuffless estimation of the BP and development of mobile healthcare device.
引用
收藏
页码:44963 / 44973
页数:11
相关论文
共 32 条
[1]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[2]  
American National Standard for Electronic or Automated Sphygmomanometers, 2002, DOCUMENT PANSIAAMI S
[3]  
Buxi D, 2015, IEEE ENG MED BIO, P5704, DOI 10.1109/EMBC.2015.7319687
[4]   Residual Water Suppression Using the Squared Eigenfunctions of the SchrOdinger Operator [J].
Chahid, Abderrazak ;
Bhaduri, Sourav ;
Maoui, Mohamed ;
Achten, Eric ;
Serrai, Hacene ;
Laleg-Kirati, Taous-Meriem .
IEEE ACCESS, 2019, 7 :69126-69137
[5]   Cuffless Differential Blood Pressure Estimation Using Smart Phones [J].
Chandrasekaran, Vikram ;
Dantu, Ram ;
Jonnada, Srikanth ;
Thiyagaraja, Shanti ;
Subbu, Kalyan Pathapati .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (04) :1080-1089
[6]   A reduced model of pulsatile flow in an arterial compartment [J].
Crepeau, Emmanuelle ;
Sorine, Michel .
CHAOS SOLITONS & FRACTALS, 2007, 34 (02) :594-605
[7]  
de la Sierra A, 2017, Hipertens Riesgo Vasc, V34, P45, DOI 10.1016/j.hipert.2016.06.004
[8]   Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio [J].
Ding, Xiao-Rong ;
Zhang, Yuan-Ting ;
Liu, Jing ;
Dai, Wen-Xuan ;
Tsang, Hon Ki .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2016, 63 (05) :964-972
[9]  
Douniama C, 2009, COMPUT CARDIOL, V36, P201
[10]   KORTEWEG-DEVRIES EQUATION AND GENERALIZATIONS .6. METHODS FOR EXACT SOLUTION [J].
GARDNER, CS ;
GREENE, JM ;
KRUSKAL, MD ;
MIURA, RM .
COMMUNICATIONS ON PURE AND APPLIED MATHEMATICS, 1974, 27 (01) :97-133