Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

被引:19
作者
Lin, MingDe [1 ,2 ]
Marshall, Craig T. [4 ,5 ]
Qi, Yi [1 ]
Johnston, Samuel M. [1 ,2 ]
Badea, Cristian T. [1 ]
Piantadosi, Claude A. [4 ,5 ]
Johnson, G. Allan [1 ,2 ,3 ]
机构
[1] Duke Univ, Med Ctr, Dept Radiol, Ctr Vivo Microscopy, Durham, NC 27710 USA
[2] Duke Univ, Med Ctr, Dept Biomed Engn, Ctr Vivo Microscopy, Durham, NC 27710 USA
[3] Duke Univ, Med Ctr, Dept Phys, Ctr Vivo Microscopy, Durham, NC 27710 USA
[4] Duke Univ, Med Ctr, Div Pulm & Crit Care Med, Durham, NC 27710 USA
[5] Duke Univ, Med Ctr, Ctr Hyperbar Med & Environm Physiol, Durham, NC 27710 USA
关键词
small animal; digital subtraction angiography; cardiovascular; pulmonary; cardiac output; blood flow; SUSCEPTIBILITY CONTRAST MRI; CARDIAC-OUTPUT; PERFUSION MRI; CT; DECONVOLUTION; DISPERSION; LUNG; VENTILATION; RESOLUTION; DELAY;
D O I
10.1118/1.3231823
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations-they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100 X 100 mu m(2)). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0 +/- 5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90 X CODSA=COFick. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3231823]
引用
收藏
页码:5347 / 5358
页数:12
相关论文
共 56 条
[41]   A liposomal nanoscale contrast agent for preclinical CT in mice [J].
Mukundan, S ;
Ghaghada, KB ;
Badea, CT ;
Kao, CY ;
Hedlund, LW ;
Provenzale, JM ;
Johnson, GA ;
Chen, E ;
Bellamkonda, RV ;
Annapragada, A .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 186 (02) :300-307
[42]   Perfusion mapping using computed tomography allows accurate prediction of cerebral infarction in experimental brain ischemia [J].
Nabavi, DG ;
Cenic, A ;
Henderson, S ;
Gelb, AW ;
Lee, TY .
STROKE, 2001, 32 (01) :175-183
[43]   Circadian and ultradian control of cardiac output in spontaneous hypertension in rats [J].
Oosting, J ;
Struijker-Boudier, HAJ ;
Janssen, BJA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 273 (01) :H66-H75
[44]   High resolution measurement of cerebral blood flow using intravascular tracer bolus passages .1. Mathematical approach and statistical analysis [J].
Ostergaard, L ;
Weisskoff, RM ;
Chesler, DA ;
Gyldensted, C ;
Rosen, BR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (05) :715-725
[45]   A MIRACLE ENOUGH - THE POWER OF MICE [J].
PAIGEN, K .
NATURE MEDICINE, 1995, 1 (03) :215-220
[46]   120-DAY STUDY OF CARDIAC OUTPUT IN UNANESTHETIZED RATS [J].
POPOVIC, VP ;
KENT, KM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1964, 207 (04) :767-+
[47]   MEASUREMENT OF DISTRIBUTION OF CARDIAC OUTPUT IN UNANESTHETIZED RATS [J].
SASAKI, Y ;
WAGNER, HN .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 30 (06) :879-&
[48]   X-ray videodensitometric methods for blood flow and velocity measurement: A critical review of literature [J].
Shpilfoygel, SD ;
Close, RA ;
Valentino, DJ ;
Duckwiler, GR .
MEDICAL PHYSICS, 2000, 27 (09) :2008-2023
[49]   Deconvolution of bolus-tracking data: a comparison of discretization methods [J].
Sourbron, S. ;
Luypaert, R. ;
Morhard, D. ;
Seelos, K. ;
Reiser, M. ;
Peller, M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (22) :6761-6778
[50]   A maximum entropy method to compute the 13NH3 pulmonary transit time from right to left ventricle in cardiac PET studies [J].
Steenstrup, S ;
Hove, JD ;
Kofoed, K ;
Kelbæk, H .
PHYSIOLOGICAL MEASUREMENT, 2002, 23 (01) :23-32