Determination of glucose in whole blood samples by mid-infrared spectroscopy

被引:42
作者
Kim, YJ [1 ]
Hahn, S [1 ]
Yoon, G [1 ]
机构
[1] Samsung Adv Inst Technol, Med Applicat Team, Suwon 440600, South Korea
关键词
D O I
10.1364/AO.42.000745
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have determined the glucose concentration of whole blood from mid-infrared spectra without sample preparation or use of chemical reagents. We selected 1119-1022 cm(-1) as the optimal wavelength range for our measurement by making a first-loading vector analysis based on partial least-squares regression. We examined the influence of hemoglobin on samples by using different calibration and prediction sets. The accuracy of glucose prediction depended on the hemoglobin level in the calibration model; the sample set should represent the entire range of hemoglobin concentration. We obtained an accuracy of 5.9% in glucose prediction, and this value is well within a clinically acceptable range. (C) 2003 Optical Society of America.
引用
收藏
页码:745 / 749
页数:5
相关论文
共 14 条
[1]  
Ashwood, 1999, TIETZ TXB CLIN CHEM, P320
[2]   MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING PARTIAL LEAST-SQUARES AND ARTIFICIAL NEURAL NETWORKS BASED ON MIDINFRARED SPECTROSCOPY [J].
BHANDARE, P ;
MENDELSON, Y ;
PEURA, RA ;
JANATSCH, G ;
KRUSEJARRES, JD ;
MARBACH, R ;
HEISE, HM .
APPLIED SPECTROSCOPY, 1993, 47 (08) :1214-1221
[3]   Application of molecular spectroscopy in the mid-infrared region to the determination of glucose and cholesterol in whole blood and in blood serum [J].
Budinova, G ;
Salva, J ;
Volka, K .
APPLIED SPECTROSCOPY, 1997, 51 (05) :631-635
[4]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202
[5]   MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD BY ATTENUATED TOTAL REFLECTION INFRARED-SPECTROSCOPY [J].
HEISE, HM ;
MARBACH, R ;
JANATSCH, G ;
KRUSEJARRES, JD .
ANALYTICAL CHEMISTRY, 1989, 61 (18) :2009-2015
[6]   MULTICOMPONENT ASSAY FOR BLOOD SUBSTRATES IN HUMAN PLASMA BY MIDINFRARED SPECTROSCOPY AND ITS EVALUATION FOR CLINICAL ANALYSIS [J].
HEISE, HM ;
MARBACH, R ;
KOSCHINSKY, T ;
GRIES, FA .
APPLIED SPECTROSCOPY, 1994, 48 (01) :85-95
[7]   Multicomponent assay for human serum using mid-infrared transmission spectroscopy based on component-optimized spectral region selected by a first loading vector analysis in partial least-squares regression [J].
Kim, YJ ;
Yoon, G .
APPLIED SPECTROSCOPY, 2002, 56 (05) :625-632
[8]  
Kuenstner JT., 1994, J Near Infrared Spetrosc, V2, P59, DOI [10.1255/jnirs.32, DOI 10.1255/JNIRS.32]
[9]  
Petibois C, 2001, CLIN CHEM, V47, P730
[10]   Disease pattern recognition in infrared spectra of human sera with diabetes mellitus as an example [J].
Petrich, W ;
Dolenko, B ;
Früh, J ;
Ganz, M ;
Greger, H ;
Jacob, S ;
Keller, F ;
Nikulin, AE ;
Otto, M ;
Quarder, O ;
Somorjai, RL ;
Staib, A ;
Warner, G ;
Wielinger, H .
APPLIED OPTICS, 2000, 39 (19) :3372-3379