Myocardial perfusion quantitation with 15O-labelled water PET: high reproducibility of the new cardiac analysis software (Carimas™)

被引:128
作者
Nesterov, Sergey V. [1 ,2 ]
Han, Chunlei [1 ]
Maki, Maija [3 ]
Kajander, Sami [1 ]
Naum, Alexandru G. [1 ,4 ]
Helenius, Hans [5 ]
Lisinen, Irina [6 ]
Ukkonen, Heikki [7 ]
Pietila, Mikko [7 ]
Joutsiniemi, Esa [7 ]
Knuuti, Juhani [1 ]
机构
[1] Univ Turku, Turku PET Ctr, Turku 20521, Finland
[2] Russian Acad Med Sci, IM Sechenov Evolutionary Physiol & Biochem Inst, St Petersburg, Russia
[3] Univ Turku, Turku Univ Hosp, Dept Clin Physiol & Nucl Med, Turku 20521, Finland
[4] Univ Bergen, Haukeland Univ Hosp, Nucl Med & PET Ctr, Bergen, Norway
[5] Univ Turku, Dept Biostat, Turku 20521, Finland
[6] Univ Turku, Res Ctr Appl & Prevent Cardiovasc Med, Turku 20521, Finland
[7] Turku Univ Hosp, Dept Internal Med, FIN-20520 Turku, Finland
基金
芬兰科学院;
关键词
Myocardial perfusion imaging; Freeware; Reproducibility; Intraclass correlation coefficient; Linear mixed models; PET; POSITRON-EMISSION-TOMOGRAPHY; DISEASE; HEART;
D O I
10.1007/s00259-009-1143-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose Carimas (TM) (Cardiac Image Analysis System) is a new software package developed at the Turku PET Centre for the quantitation of PET studies of the heart with a broad range of tracers. The goal of this study was to assess the reproducibility of results the package provides for myocardial perfusion (MP) quantitation using (15)O-labelled water. Methods Four observers with various levels of experience in nuclear medicine independently analysed 20 MP studies (10 rest flow: "rest", 10 adenosine-induced hyperaemia: "stress"). Each study was analysed twice. The linear mixed model for repeated measures was fitted to the data to calculate intraclass correlation coefficients (ICC), differences between the repeats (the intraobserver differences) and differences between the observers (the interobserver differences). Also, Pearson correlation coefficients (r) were calculated and Bland-Altman plots were drawn. The reproducibility of MP was assessed on global, regional and segmental levels. Thereafter, this analysis was applied in 48 consecutive clinical patients with suspected coronary heart disease (CHD). Results For the experienced observer the Pearson r for all segments was 0.974 at rest and 0.978 at stress (p< 0.0001), and the repeatability coefficients were 0.145 ml/g per min (15.5% of the average) and 0.389 ml/g per min (14.9%), correspondingly. The ICC reflected very good overall reproducibility. The intraobserver and interobserver differences were small, and the difference between the most and the least experienced observers at stress was 8.5% for the global MP. The clinical accuracy of the perfusion in the detection of CHD was excellent (positive predictive value 91% and negative predictive value 88%) against invasive angiography. Conclusion The results demonstrate high reproducibility of myocardial perfusion quantitation with (15)O-labelled water PET using Carimas (TM). The results support the feasibility of robust analysis and good clinical accuracy.
引用
收藏
页码:1594 / 1602
页数:9
相关论文
共 18 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[3]   SAFETY PROFILE OF ADENOSINE STRESS PERFUSION IMAGING - RESULTS FROM THE ADENOSCAN-MULTICENTER-TRIAL-REGISTRY [J].
CERQUEIRA, MD ;
VERANI, MS ;
SCHWAIGER, M ;
HEO, J ;
ISKANDRIAN, AS ;
ALAZRAKI, NP ;
BEAN, LC ;
BELARDINELLI, L ;
BELL, M ;
BERMAN, DS ;
BOTVINICK, EH ;
CHEIRIF, J ;
HANSEN, CL ;
HELLER, GV ;
JOHNSTON, DL ;
LEPPO, JA ;
MADDAHI, J ;
PARKER, LS ;
MOHIUDDIN, S ;
RAICHLEN, JS ;
REIS, GJ ;
SCHELBERT, HR ;
SEALS, AA ;
STOLZENBERG, J ;
WILLIAMS, KA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) :384-389
[4]  
Davis CR, 2002, STAT METHODS ANAL RE, P125
[5]  
Fleiss JL., 1986, DESIGN ANAL CLIN EXP
[6]   IMAGING OF THE HEART BY MRI AND PET [J].
HARTIALA, J ;
KNUUTI, J .
ANNALS OF MEDICINE, 1995, 27 (01) :35-45
[7]  
IIDA H, 1992, J NUCL MED, V33, P1669
[8]  
IIDA H, 1991, J NUCL MED, V32, P2169
[9]  
Katoh C, 2004, J NUCL MED, V45, P1908
[10]  
Kaufmann PA, 2005, J NUCL MED, V46, P75