GC-MS quantification of suspected volatile allergens in fragrances. 2. Data treatment strategies and method performances

被引:23
作者
Bassereau, Maud
Chaintreau, Alain
Duperrex, Stephanie
Joulain, Daniel
Leijs, Hans
Loesing, Gerd
Owen, Neil
Sherlock, Alan
Schippa, Christine
Thorel, Pierre-Jean
Vey, Matthias
机构
[1] Firmenich Co, Corp R&D Div, CH-1211 Geneva 8, Switzerland
[2] Takasago, F-95310 St Ouen Aumone, France
[3] Givaudan, F-95101 Argenteuil, France
[4] Robertet SA, F-06131 Grasse, France
[5] IFF, NL-5004 EA Tilburg, Netherlands
[6] Symrise, D-37601 Holzminden, Germany
[7] Quest Int UK, Ashford TN24 0LT, Kent, England
[8] Treatt, Bury St Edmunds IP32 6NL, Suffolk, England
[9] V Mane Fils SA, F-06620 Le Bar Sur Loup, France
[10] Givaudan SA, CH-1214 Vernier, Switzerland
[11] IFRA, B-1210 Brussels, Belgium
关键词
allergens; GC-MS; quantification; skin reaction; fragrances; perfumes; variability; quantification limit;
D O I
10.1021/jf062028l
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The performances of the GC-MS determination of suspected allergens in fragrance concentrates have been investigated. The limit of quantification was experimentally determined (10 mg/L), and the variability was investigated for three different data treatment strategies: (1) two columns and three quantification ions; (2) two columns and one quantification ion; and (3) one column and three quantification ions. The first strategy best minimizes the risk of determination bias due to coelutions. This risk was evaluated by calculating the probability of coeluting a suspected allergen with perfume constituents exhibiting ions in common. For hydroxycitronellal, when using a two-column strategy, this may statistically occur more than once every 36 analyses for one ion or once every 144 analyses for three ions in common.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 19 条
[1]  
[Anonymous], 2002, OFFICIAL J EUROPEAN
[2]  
[Anonymous], 2017, MASS SPECTROMETRY TX, DOI 10.1007/978-3-319-54398-7
[3]  
Bertsch W, 1999, HRC-J HIGH RES CHROM, V22, P647, DOI 10.1002/(SICI)1521-4168(19991201)22:12<647::AID-JHRC647>3.0.CO
[4]  
2-V
[5]   An analysis of the SFSTP guide on validation of chromatographic bioanalytical methods: progresses and limitations [J].
Boulanger, B ;
Chiap, P ;
Dewe, W ;
Crommen, J ;
Hubert, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 32 (4-5) :753-765
[6]   GC-MS quantitation of fragrance compounds suspected to cause skin reactions. 1 [J].
Chaintreau, A ;
Joulain, D ;
Marin, C ;
Schmidt, CO ;
Vey, M .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (22) :6398-6403
[7]  
DAVIS JM, 1983, ANAL CHEM, V55, P418, DOI 10.1021/ac00254a003
[8]   Hyphenation of quadrupole MS to GC and comprehensive two-dimensional GC for the analysis of suspected allergens:: Review and improvement [J].
Debonneville, C ;
Thomé, MA ;
Chaintreau, A .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2004, 42 (08) :450-455
[9]  
ELLENDT K, 2001, SOFW-J, V127, P29
[10]   A global approach to method validation and measurement uncertainty [J].
Feinberg, M ;
Laurentie, M .
ACCREDITATION AND QUALITY ASSURANCE, 2006, 11 (1-2) :3-9