Ionic liquid-based dispersive liquid-liquid microextraction followed high-performance liquid chromatography for the determination of organophosphorus pesticides in water sample

被引:192
作者
He, Lijun [1 ]
Luo, Xianli [1 ]
Xie, Hongxue [1 ]
Wang, Chunjian [1 ]
Jiang, Xiuming [1 ]
Lu, Kui [1 ]
机构
[1] Henan Univ Technol, Sch Chem & Chem Engn, Zhengzhou 450001, Peoples R China
基金
中国国家自然科学基金;
关键词
Ionic liquid; Dispersive liquid-liquid microextraction; Organophosphorus pesticide; High-performance liquid chromatography; POLYCYCLIC AROMATIC-HYDROCARBONS; MICROWAVE-ASSISTED EXTRACTION; FLAME PHOTOMETRIC DETECTION; PHASE MICROEXTRACTION; GAS-CHROMATOGRAPHY; SINGLE-DROP; MASS SPECTROMETRY; ORGANIC-COMPOUNDS; SOLVENT; SEPARATION;
D O I
10.1016/j.aca.2009.09.044
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Using 1-octyl-3-methylimidazolium hexafluorophosphate ([C8MIM][PF6]) ionic liquid as extraction solvent, organophosphorus pesticides (OPPs) (parathion, phoxim, phorate and chlorpyifos) in water were determined by dispersive liquid-liquid microextraction (DLLME) combined with high-performance liquid chromatography (HPLC). The extraction procedure was induced by the formation of cloudy solution, which was composed of fine drops of [C8MIM][PF6] dispersed entirely into sample solution with the help of disperser solvent (methanol). Parameters including extraction solvent and its volume, disperser solvent and its volume, extraction time, centrifugal time, salt addition, extraction temperature and sample pH were investigated and optimized. Under the optimized conditions, up to 200-fold enrichment factor of analytes and acceptable extraction recovery (>70%) were obtained. The calibration curves were linear in the concentration range of 10.5-1045.0 mu g L-1 for parathion, 10.2-1020.0 mu g L-1 for phoxim, 54.5-1089.0 mu g L-1 for phorate and 27.2-1089.0 mu g L-1 for chlorpyifos, respectively. The limits of detection calculated at a signal-to-noise ratio of 3 were in the range of 0.1-5.0 mu g L-1. The relative standard deviations for seven replicate experiments at 200 mu g L-1 concentration level were less than 4.7%. The proposed method was applied to the analysis of four different sources water samples (tap, well, rain and Yellow River water) and the relative recoveries of spiked water samples are 99.9-115.4%, 101.8-113.7% and 87.3-117.6% at three different concentration levels of 75, 200 and 1000 mu g L-1, respectively. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 38 条
[1]   Determination of trihalomethanes in waters by ionic liquid-based single drop microextraction/gas chromatographic/mass spectrometry [J].
Aguilera-Herrador, Eva ;
Lucena, Rafael ;
Cardenas, Soledad ;
Valcarcel, Miguel .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1209 (1-2) :76-82
[2]   Role of B-esterases in assessing toxicity of organophosphorus (chlorpyrifos, malathion) and carbamate (carbofuran) pesticides to Daphnia magna [J].
Barata, C ;
Solayan, A ;
Porte, C .
AQUATIC TOXICOLOGY, 2004, 66 (02) :125-139
[3]   Dispersive liquid-liquid microextraction combined with gas chromatography-flame photometric detection - Very simple, rapid and sensitive method for the determination of organophosphorus pesticides in water [J].
Berijani, Sana ;
Assadi, Yaghoub ;
Anbia, Mansoor ;
Milani Hosseini, Mohammad-Reza ;
Aghaee, Elham .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1123 (01) :1-9
[4]   Liquid-phase microextraction of drugs from human breast milk [J].
Bjorhovde, A ;
Halvorsen, TG ;
Rasmussen, KE ;
Pedersen-Bjergaard, S .
ANALYTICA CHIMICA ACTA, 2003, 491 (02) :155-161
[5]  
Branco LC, 2002, ANGEW CHEM INT EDIT, V41, P2771, DOI 10.1002/1521-3773(20020802)41:15<2771::AID-ANIE2771>3.0.CO
[6]  
2-U
[7]  
Chen PS, 2006, TALANTA, V69, P669, DOI 10.1016/j.talanta.2005.10.042
[8]   Ionic liquid-based dynamic liquid-phase microextraction:: Application to the determination of anti-inflammatory drugs in urine samples [J].
Cruz-Vera, Marta ;
Lucena, Rafael ;
Cardenas, Soledad ;
Valcarcel, Miguel .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1202 (01) :1-7
[9]   Application of ionic liquids in the microwave-assisted extraction of trans-resveratrol from Rhizma Polygoni Cuspidati [J].
Du, Fu-You ;
Mao, Xiao-Hua ;
Li, Gong-Ke .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1140 (1-2) :56-62
[10]   Determination of fentanyl in biological and water samples using single-drop liquid-liquid-liquid microextraction coupled with high-performance liquid chromatography [J].
Ebrahimzadeh, H. ;
Yamini, Y. ;
Gholizade, A. ;
Sedighi, A. ;
Kasraee, S. .
ANALYTICA CHIMICA ACTA, 2008, 626 (02) :193-199