A modified zeolite/iron oxide composite as a sorbent for magnetic dispersive solid-phase extraction for the preconcentration of nonsteroidal anti-inflammatory drugs in water and urine samples

被引:54
作者
Baile, Paola [1 ,2 ]
Vidal, Lorena [1 ,2 ]
Canals, Antonio [1 ,2 ]
机构
[1] Univ Alicante, Dept Quim Analit Nutr & Bromatol, POB 99, E-03080 Alicante, Spain
[2] Univ Alicante, Inst Univ Mat, POB 99, E-03080 Alicante, Spain
关键词
Zeolite; Surfactant; Magnetic dispersive solid-phase extraction; Nonsteroidal anti-inflammatory drugs; Water samples; Urine samples; PERFORMANCE LIQUID-CHROMATOGRAPHY; MOLECULARLY IMPRINTED POLYMER; METAL-ORGANIC FRAMEWORK; PACKED SORBENT; CATIONIC SURFACTANT; PHARMACEUTICAL RESIDUES; ENVIRONMENTAL-SAMPLES; BIOLOGICAL-FLUIDS; IONIC LIQUIDS; HUMAN PLASMA;
D O I
10.1016/j.chroma.2019.06.039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study is the first to use a new ZSM-5 zeolite-based composite decorated with iron oxide magnetic nanoparticles and modified with hexadecyltrimethylammonium bromide surfactant (i.e., HDTMA-ZSM-5/Fe2O3) as an efficient sorbent for magnetic dispersive solid-phase extraction (MDSPE) of nonsteroidal anti-inflammatory drugs in water and urine samples with subsequent measurement by liquid chromatography diode array detection. Experimental factors affecting MDSPE were optimized using a multivariate optimization strategy. The optimum experimental conditions were: amount of sorbent, 40 mg; sample pH, 2.2; NaCl concentration, 2.5%; extraction time, 2 min; eluent solvent, methanol; eluent solvent volume, 424 mu L; and elution time, 2 min. The linearity of the method was studied from 3.3 to 400 mu g L-1 (N=8) for ketoprofen, from 1.7 to 400 mu g L-1 (N =8) for felbinac, from 6.6 to 400 mu g L-1 (N=7) for diclofenac and from 9.9 to 400 mu g L-1 (N = 6) for ibuprofen. Method repeatability was evaluated at 10 and 200 mu g L-1 spiking levels, obtaining coefficients of variation between 2 and 5% (n = 6). Limits of detection, determined empirically, were 1.0 mu g L-1, 0.5 mu g L-1, 2.0 mu g L-1 and 3.0 mu g L-1 for ketoprofen, felbinac, diclofenac and ibuprofen, respectively. Tap water, reservoir water, wastewater and five urine samples were selected to assess method applicability. Recovery values ranged between 86-107% and 80-112% for water and urine samples, respectively, showing negligible matrix effects. Finally, this method was employed to monitor ibuprofen excretion in real urine samples. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:33 / 43
页数:11
相关论文
共 71 条
[1]   Magnetic solid-phase extraction of non-steroidal anti-inflammatory drugs from environmental water samples using polyamidoamine dendrimer functionalized with magnetite nanoparticles as a sorbent [J].
Alinezha, Heshmatollah ;
Amiri, Amirhassan ;
Tarahomi, Mehrasa ;
Maleki, Behrooz .
TALANTA, 2018, 183 :149-157
[2]   Magnetite nanoparticles coated with covalently immobilized ionic liquids as a sorbent for extraction of non-steroidal anti-inflammatory drugs from biological fluids [J].
Amiri, Maryam ;
YadollahYamini ;
Safari, Meysam ;
Asiabi, Hamid .
MICROCHIMICA ACTA, 2016, 183 (07) :2297-2305
[3]   Modification of an Iranian clinoptilolite nano-particles by hexadecyltrimethyl ammonium cationic surfactant and dithizone for removal of Pb(II) from aqueous solution [J].
Anari-Anaraki, Mostafa ;
Nezamzadeh-Ejhieh, Alireza .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2015, 440 :272-281
[4]  
[Anonymous], 2014, Eurachem Guide: The Fitness for Purpose of Analytical Methods - A Laboratory Guide to Method Validation and Related Topics
[5]  
[Anonymous], 2003, HDB ZEOLITE SCI TECH
[6]  
[Anonymous], 2009, DESIGN ANAL EXPT
[7]  
[Anonymous], 2011, Int J Interf Cytokine Mediat Res, DOI [DOI 10.2147/IJICMR.S10200, 10.2147/IJICMR.S10200]
[8]  
ARMBRUSTER DA, 1994, CLIN CHEM, V40, P1233
[9]   An On-line Admicellar SPE-HPLC System Using CTAB-Modified Zeolite NaY as Sorbent for Determination of Carbamate Pesticides in Water [J].
Arnnok, Prapha ;
Patdhanagul, Nopbhasinthu ;
Burakham, Rodjana .
CHROMATOGRAPHIA, 2015, 78 (21-22) :1327-1337
[10]   Retention of Carbamate Pesticides by Different Surfactant-Modified Sorbents: Comparative Study [J].
Arnnok, Prapha ;
Burakham, Rodjana .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2014, 25 (09) :1720-1729