Improved direct piezoelectric biosensors operating in liquid solution for the competitive label-free immunoassay of 2,4-dichlorophenoxyacetic acid

被引:82
作者
Horacek, J [1 ]
Skladal, P [1 ]
机构
[1] MASARYK UNIV,DEPT BIOCHEM,CZ-61137 BRNO,CZECH REPUBLIC
关键词
immunosensor; quartz crystal microbalance; piezoelectric biosensor; 2,4-dichlorophenoxyacetic acid; pesticides;
D O I
10.1016/S0003-2670(97)00125-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of a label-free direct piezoelectric immunosensor is reported. The piezoelectric crystals were modified with 2,4-dichlorophenoxyacetic acid (2,4-D) using coupling procedures based on self-assembled monolayers of suitable thiocompounds (aminothiophenol, cysteamine, cystine and dithiobis(succinimidyl)propionate) on the surface of gold electrodes of the crystals. The piezoelectric biosensor has been placed in a flow-through cell and the affinity binding of two monoclonal antibodies against 2,4-D on the modified piezoelectric crystals was studied in real time without any additional labels. For the interactions, the kinetic equilibrium association constants K-a were 12.6 and 25.0 mu M-1 for the antibodies E2/G2 and E4/C2, respectively. The system was used for competitive determination of free 2,4-D in water. For the antibodies E2/G2 and E4/C2 (both in concentration of 15 mu g/ml), the limits of detection (10% decrease of relative binding of the antibody) for free 2,4-D were 0.27 and 0.24 mu g/l, respectively. The total time for one measurement was below 25 min (10 min preincubation of antibody with sample, 10 min binding reaction, 5 min regeneration).
引用
收藏
页码:43 / 50
页数:8
相关论文
共 29 条
[1]   CRITICAL ISSUES IN APPLICATIONS OF SELF-ASSEMBLED MONOLAYERS [J].
ALLARA, DL .
BIOSENSORS & BIOELECTRONICS, 1995, 10 (9-10) :771-783
[2]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[3]  
Bier FF, 1996, FRESEN J ANAL CHEM, V354, P861
[4]   Electrochemical immunosensors for determination of the pesticides 2,4-dichlorophenoxyacetic and 2,4,5-trichlorophenoxyacetic acids [J].
Dzantiev, BB ;
Zherdev, AV ;
Yulaev, MF ;
Sitdikov, RA ;
Dmitrieva, NM ;
Moreva, IY .
BIOSENSORS & BIOELECTRONICS, 1996, 11 (1-2) :179-185
[5]  
FLEEKER J, 1987, J ASSOC OFF ANA CHEM, V70, P874
[6]   MONOCLONAL ELISA FOR 2,4-DICHLOROPHENOXYACETIC ACID - CHARACTERIZATION OF ANTIBODIES AND ASSAY OPTIMIZATION [J].
FRANEK, M ;
KOLAR, V ;
GRANATOVA, M ;
NEVORANKOVA, Z .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1994, 42 (06) :1369-1374
[7]   IMMUNOASSAYS FOR THE DETECTION OF 2,4-D AND PICLORAM IN RIVER WATER AND URINE [J].
HALL, JC ;
DESCHAMPS, RJA ;
KRIEG, KK .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1989, 37 (04) :981-984
[8]  
HERMANSON GT, 1992, IMMOBILIZED AFFINITY, P69
[9]   USE OF IMMUNOCHEMICAL TECHNIQUES FOR THE ANALYSIS OF PESTICIDES [J].
JUNG, F ;
GEE, SJ ;
HARRISON, RO ;
GOODROW, MH ;
KARU, AE ;
BRAUN, AL ;
LI, QX ;
HAMMOCK, BD .
PESTICIDE SCIENCE, 1989, 26 (03) :303-317
[10]   A DISPOSABLE AMPEROMETRIC IMMUNOSENSOR FOR 2,4-DICHLOROPHENOXYACETIC ACID [J].
KALAB, T ;
SKLADAL, P .
ANALYTICA CHIMICA ACTA, 1995, 304 (03) :361-368