Determination of Analgesics (Dipyrone and Acetaminophen) in Pharmaceutical Preparations by Cyclic Voltammetry at a Copper(II) Hexacyanoferrate(III) Modified Carbon Paste Electrode

被引:27
作者
Teixeira, Marcos F. S. [1 ]
Marcolino-Junior, Luiz H. [2 ]
Fatibello-Filho, Orlando [3 ]
Moraes, Fernando C. [3 ]
Nunes, Ronaldo S. [4 ]
机构
[1] Univ Estadual Paulista, Fac Ciencias & Tecnol, Dept Fis Quim & Biol, UNESP, BR-19060900 Presidente Prudente, SP, Brazil
[2] Univ Fed Parana, Dept Quim, Curitiba, SP, Brazil
[3] Univ Fed Sao Carlos, Dept Quim, BR-13560 Sao Carlos, SP, Brazil
[4] Univ Sao Paulo, Dept Quim & Fis Mol, IQSC, Sao Carlos, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Modified carbon paste electrode; Copper(II) hexacyanoferrate(III); Voltammetric determination; Analgesics; Pharmaceutical preparations; AMPEROMETRIC DETERMINATION; SPECTROPHOTOMETRIC DETERMINATION; PARACETAMOL; BIOSENSORS;
D O I
10.2174/157341109789077759
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Copper(II) hexacyanoferrate(III) (CuHCF) modified carbon paste electrode was used for the electroanalytical determination of dipyrone and acetaminophen in pharmaceutical preparations by cyclic voltammetry. Several parameters were investigated for the optimization of the sensor such as composition of the electrode, electrolytic solution, effect of pH, scan rate of potential and interference. The best conditions were found for an electrode composition in mass of 20% CuHCF, 55% graphite and 25% mineral oil in acetate buffer containing 0.05 mol L-1 of NaCl. The analytical curve was linear in the dipyrone and acetaminophen concentration ranged from 1.25 x 10(-5) mol L-1 to 1.23 x 10(-3) and 2.84 x 10(-4) to 2.59 x 10(-3) mol L-1 respectively, being successfully applied to the determination of dipyrone and acetaminophen in pharmaceutical preparations. The CuHCF modified carbon paste electrode presented comparable results to those obtained using iodimetry and ultraviolet spectrophotometry methods, respectively.
引用
收藏
页码:303 / 310
页数:8
相关论文
共 37 条
[1]   Electrocatalytic oxidation of hydrazine on a carbon paste electrode modified by hybrid hexacyanoferrates of copper and cobalt films [J].
Abbaspour, A ;
Kamyabi, MA .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2005, 576 (01) :73-83
[2]  
BROWN ER, 1971, TECHNIQUES CHEM, V1, P488
[3]   Chemometric approach to simultaneous chromatographic determination of paracetamol and chlorzoxazone in tablets and spiked human plasma [J].
Dinç, E ;
Ozdemir, A ;
Aksoy, H ;
Baleanu, D .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2006, 29 (12) :1803-1822
[4]   Simultaneous spectrophotometric determination of mefenamic acid and paracetamol in a pharmaceutical preparation using ratio spectra derivative spectrophotometry and chemometric methods [J].
Dinç, E ;
Yücesoy, C ;
Onur, F .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 28 (06) :1091-1100
[5]   Carbon film resistor electrode for amperometric determination of acetaminophen in pharmaceutical formulations [J].
Felix, Fabiana S. ;
Brett, Christopher M. A. ;
Angnes, Lucio .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) :1622-1627
[6]  
Gálvez AM, 1999, ANAL CHIM ACTA, V396, P161
[7]   Simultaneous, stability indicating, HPLC-DAD determination of guaifenesin and methyl and propyl-parabens in cough syrup [J].
Grosa, G ;
Del Grosso, E ;
Russo, R ;
Allegrone, G .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) :798-803
[8]   Cerium (IV)-based chemiluminescence analysis of analgin [J].
Huang, YM ;
Zhang, C ;
Zhang, XR ;
Zhang, ZJ .
ANALYTICAL LETTERS, 1999, 32 (05) :933-943
[9]   CHEMICALLY MODIFIED CARBON PASTE ELECTRODES IN VOLTAMMETRIC ANALYSIS [J].
KALCHER, K .
ELECTROANALYSIS, 1990, 2 (06) :419-433
[10]   Prussian-Blue-based amperometric biosensors in flow-injection analysis [J].
Karyakin, AA ;
Karyakina, EE ;
Gorton, L .
TALANTA, 1996, 43 (09) :1597-1606