共 29 条
Area of the tibial insertion site of the anterior cruciate ligament as a predictor for graft size
被引:17
作者:
Guenther, Daniel
[1
,2
]
Irarrazaval, Sebastian
[1
]
Albers, Marcio
[1
]
Vernacchia, Cara
[1
]
Irrgang, James J.
[1
]
Musahl, Volker
[1
]
Fu, Freddie H.
[1
]
机构:
[1] Univ Pittsburgh, Sch Med, Dept Orthopaed Surg, Kaufman Med Bldg,Suite 1011,3941 Fifth Ave, Pittsburgh, PA 15203 USA
[2] Hannover Med Sch MHH, Trauma Dept, Hannover, Germany
关键词:
Tibial insertion site;
Anterior cruciate ligament;
ACL;
Individualized;
Anatomy;
Graft size;
HAMSTRING AUTOGRAFT SIZE;
CROSS-SECTIONAL AREA;
ACL RECONSTRUCTION;
SINGLE-BUNDLE;
RISK;
FOOTPRINT;
ALLOGRAFT;
REVISION;
OUTCOMES;
FAILURE;
D O I:
10.1007/s00167-016-4295-7
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
To determine the distribution of different sizes of the area of the tibial insertion site among the population and to evaluate whether preoperative MRI measurements correlate with intraoperative findings to enable preoperative planning of the required graft size to cover the tibial insertion site sufficiently. The hypothesis was that the area of the tibial insertion site varies among individuals and that there is good agreement between MRI and intraoperative measurements. Intraoperative measurements of the tibial insertion site were taken on 117 patients. Three measurements were taken in each plane building a grid to cover the tibial insertion site as closely as possible. The mean of the three measurements in each plane was used for determination of the area. Two orthopaedic surgeons, who were blinded to the intraoperative measurements, took magnetic resonance imaging (MRI) measurements of the area of the tibial insertion site at two different time points. The intraoperative measured mean area was 123.8 +/- 21.5 mm(2). The mean area was 132.8 +/- 15.7 mm(2) (rater 1) and 136.7 +/- 15.4 mm(2) (rater 2) when determined using MRI. The size of the area was approximately normally distributed. Inter-rater (0.89; 95 % CI 0.84, 0.92; p < 0.001) and intrarater reliability (rater 1: 0.97; 95 % CI 0.95, 0.98; p < 0.001; rater 2: 0.95; 95 % CI 0.92, 0.96; p < 0.001) demonstrated excellent test-retest reliability. There was good agreement between MRI and intraoperative measurement of tibial insertion site area (ICCs rater 1: 0.80; 95 % CI 0.71, 0.87; p < 0.001; rater 2: 0.87; 95 % CI 0.81, 0.91; p < 0.001). The tibial insertion site varies in size and shape. Preoperative determination of the area using MRI is repeatable and enables planning of graft choice and size to optimally cover the tibial insertion site. III.
引用
收藏
页码:1576 / 1582
页数:7
相关论文