Endobutton Repair of Distal Biceps Tendon Ruptures

被引:21
|
作者
Greenberg, Jeffrey A. [1 ]
机构
[1] Indiana Hand Ctr, Indianapolis, IN 46260 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2009年 / 34A卷 / 08期
关键词
Biceps tendon; tendon rupture; tendon repair; endobutton; BRACHII TENDON; ANATOMIC REINSERTION; 2-INCISION TECHNIQUE; COMPLICATIONS;
D O I
10.1016/j.jhsa.2009.05.021
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Anatomic reconstruction is now recognized as the optimal treatment for distal biceps ruptures to maximize functional upper extremity potential. Reconstruction minimizes the loss of flexion and supination strength and endurance that is associated with neglected or untreated ruptures. A single-incision, anterior approach for reconstruction of distal ruptures is facilitated by the use of a titanium button that is anchored to the end of the tendon and then engaged on the posterior proximal radius. This construct has been shown to have superior strength, facilitating early rehabilitation and return to activity. (J Hand Surg 2009;34A:1541-1548. (C) 2009 Published by Elsevier Inc. on behalf of the American Society for Surgery of the Hand.)
引用
收藏
页码:1541 / 1548
页数:8
相关论文
共 50 条
  • [1] Repair of the torn distal biceps tendon by endobutton fixation
    Gupta, Ravi K.
    Bither, Nitin
    Singh, Harpreet
    Kapoor, Saurabh
    Chhabra, Ashish
    Garg, Sudhir
    INDIAN JOURNAL OF ORTHOPAEDICS, 2012, 46 (01) : 71 - 76
  • [2] Functional outcome after repair of distal biceps tendon ruptures using the endobutton technique
    Peeters, Tom
    Ching-Soon, N. G.
    Jansen, Nick
    Sneyers, Claire
    DecLercq, Geert
    Verstreken, Frederik
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (02) : 283 - 287
  • [3] Repair of the torn distal biceps tendon by endobutton fixation
    Ravi K. Gupta
    Nitin Bither
    Harpreet Singh
    Saurabh Kapoor
    Ashish Chhabra
    Sudhir Garg
    Indian Journal of Orthopaedics, 2012, 46 : 71 - 76
  • [4] A comparison of nonoperative vs. Endobutton repair of distal biceps ruptures
    Legg, Andrew J.
    Stevens, Richard
    Oakes, Nanette O.
    Shahane, Shantanu A.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (03) : 341 - 348
  • [5] Repair Techniques for Acute Distal Biceps Tendon Ruptures
    Watson, Jonathan N.
    Moretti, Vincent M.
    Schwindel, Leslie
    Hutchinson, Mark R.
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (24) : 2086 - 2090
  • [6] Evaluation of Surgical Repair of Distal Biceps Tendon Ruptures
    Behounek, J.
    Hrubina, M.
    Skotak, M.
    Krumpl, O.
    Zahalka, M.
    Dvorak, J.
    Fucik, M.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2009, 76 (01) : 47 - 53
  • [7] Endoscopic repair of distal biceps tendon using an EndoButton
    Sharma, S
    MacKay, G
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (07) : 897.e1 - 897.e4
  • [8] Single incision technique for distal biceps tendon repair: Using the Endobutton
    Fox, JA
    Fernandez, JJ
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2003, 11 (01) : 42 - 46
  • [9] Distal Biceps Tendon- and Triceps Tendon Ruptures
    Freislederer, Florian
    Papillo, Donato
    Glanzmann, Michael
    Scheibel, Markus
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2020, 158 (06): : 663 - 680
  • [10] Distal biceps reconstruction using an Achilles tendon allograft, transosseous EndoButton, and Pulvertaft weave with tendon wrap technique for retracted, irreparable distal biceps ruptures
    Phadnis, Joideep
    Flannery, Olivia
    Watts, Adam C.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (06) : 1013 - 1019