Impact of the Balloon Inflation Time and Pattern on the Coronary Stent Expansion

被引:5
|
作者
Skowronski, Jaroslaw [1 ]
Wolny, Rafal [1 ]
Jastrzebski, Jan [1 ]
Tyczynski, Pawel [1 ]
Szlazak, Karol [2 ]
Pregowski, Jerzy [1 ]
Mintz, Gary S. [3 ]
Lizewska, Karolina [2 ]
Swieszkowski, Wojciech [2 ]
Chmielak, Zbigniew [1 ]
Witkowski, Adam [1 ]
机构
[1] Inst Cardiol, Dept Intervent Cardiol & Angiol, Warsaw, Poland
[2] Warsaw Univ Technol, Fac Mat Sci & Engn, Warsaw, Poland
[3] Cardiovasc Res Fdn, New York, NY USA
关键词
OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; IMPLANTATION; THROMBOSIS; DEPLOYMENT; UNDEREXPANSION; OUTCOMES; IVUS;
D O I
10.1155/2019/6945372
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To assess the expansion pattern of coronary stents by using different balloon inflation times and pressures. Background. The selection of coronary stent size and its proper deployment is crucial in coronary artery interventions, having an impact on the success of the procedure and further therapy. Methods. Ten pairs of different stents were deployed under nominal pressure using sequential (5, 5, 10, and 10 seconds of repeated inflations, thus 30 seconds of summarized time) and continuous (30 seconds) deployment pattern. After each given time-point, intraluminal stent measurements were performed by optical coherence tomography (OCT) and intravascular ultrasound (IVUS). Results. Both in-stent diameters and cross-section areas (CSA) of paired stents measured by OCT at all sequential time-points were significantly smaller compared to given manufacturers charts' values (90% to 94% for diameters and 81% to 88% for CSA, p<0.05). Significant increase of in-stent diameter and CSA was observed across the step-by-step deployment pattern. In-stent lumen measurements were significantly larger when sequential deployment pattern was applied compared to continuous deployment. Additional measurements were also done for overlapping segments of stents, showing smaller in-stent measurements of the latter compared to nonoverlapping segments. Validation of OCT and IVUS measurements using a phantom metallic tube showed perfect reproducibility with OCT and overestimation with IVUS (8% for diameters and 16% for CSA). Conclusions. Stent diameter after deployment is time-dependent and not only pressure-dependent. Different stent expansion behavior, depending on the applied deployment pattern (sequential and nonsequential), was observed.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A novel hybrid strategy of drug coated balloon and stent for coronary bifurcation lesions
    Yang, Hongbo
    Song, Yanan
    Cao, Jiatian
    Chen, Jing
    Zhang, Feng
    Huang, Zheyong
    Qian, Juying
    Ge, Junbo
    SCANDINAVIAN CARDIOVASCULAR JOURNAL, 2023, 57 (01)
  • [42] Stent Expansion After Additional Non-Compliant Balloon High-Pressure Inflation in Patients With Drug-Eluting Stent Underexpansion: An Intravascular Ultrasound Study
    Kim, Sang-Wook
    Lee, Wang Soo
    Mintz, Gary S.
    Hong, Young Joon
    Lee, Sung Yun
    Lee, Kwang Je
    Kim, Tae Ho
    Kim, Chee Jeong
    Ryu, Wang Seong
    Pichard, August D.
    Weissman, Neil J.
    CIRCULATION, 2010, 122 (21)
  • [43] Buddy Balloon versus Buddy Wire Technique Regarding Accuracy of Stent Placement during Percutaneous Coronary Intervention
    He, Yun
    Shen, Bin
    Song, MingBao
    Nienaber, Christoph A.
    Zheng, Yi
    Lu, XueMei
    Xiao, Qing
    Yang, XiaoLing
    Bi, Shuo
    Jin, Jun
    INTERNATIONAL HEART JOURNAL, 2022, 63 (04) : 654 - 660
  • [44] Impact of Angiographic Result After Predilatation on Outcome After Drug-Coated Balloon Treatment of In-Stent Coronary Restenosis
    Tanaka, Akihito
    Latib, Azeem
    Jabbour, Richard J.
    Kawamoto, Hiroyoshi
    Giannini, Francesco
    Ancona, Marco
    Regazzoli, Damiano
    Mangieri, Antonio
    Mattioli, Roberto
    Chieffo, Alaide
    Carlino, Mauro
    Montorfano, Matteo
    Colombo, Antonio
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 118 (10) : 1460 - 1465
  • [45] On the importance of modeling balloon folding, pleating, and stent crimping: An FE study comparing experimental inflation tests
    Geith, Markus A.
    Swidergal, Krzysztof
    Hochholdinger, Bernd
    Schratzenstaller, Thomas G.
    Wagner, Marcus
    Holzapfel, Gerhard A.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2019, 35 (11)
  • [46] Paclitaxel-coated balloon in combination with bare metal stent for treatment of de novo coronary lesions: an optical coherence tomography first-in-human randomised trial, balloon first vs. stent first
    Gutierrez-Chico, Juan Luis
    van Geuns, Robert Jan
    Koch, Karel T.
    Koolen, Jacques J.
    Duckers, Henricus
    Regar, Evelyn
    Serruys, Patrick W.
    EUROINTERVENTION, 2011, 7 (06) : 711 - 722
  • [47] Impact of intravascular ultrasound and final kissing balloon dilatation on long-term clinical outcome in percutaneous revascularization with 1-stent strategy for left main coronary artery stenosis in drug-eluting stent era
    Yoon, Jae Yong
    Lee, Jang Hoon
    Choi, Hyohun
    Park, Hyuk Kyoon
    Lee, Eunkyu
    Kim, Myeong Seop
    Kwon, Youngjoon
    Jang, Se Yong
    Bae, Myung Hwan
    Yang, Dong Heon
    Park, Hun Sik
    Cho, Yongkeun
    Chae, Shung Chull
    CORONARY ARTERY DISEASE, 2022, 31 (01) : 9 - 17
  • [48] Drug-Coated Balloon Angioplasty Versus Drug-Eluting Stent Implantation in Patients With Coronary Stent Restenosis
    Giacoppo, Daniele
    Alfonso, Fernando
    Xu, Bo
    Claessen, Bimmer E. P. M.
    Adriaenssens, Tom
    Jensen, Christoph
    Perez-Vizcayno, Maria J.
    Kang, Do-Yoon
    Degenhardt, Ralf
    Pleva, Leos
    Baan, Jan
    Cuesta, Javier
    Park, Duk-Woo
    Kukla, Pavel
    Jimenez-Quevedo, Pilar
    Unverdorben, Martin
    Gao, Runlin
    Naber, Christoph K.
    Park, Seung-Jung
    Henriques, Jose P. S.
    Kastrati, Adnan
    Byrne, Robert A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 75 (21) : 2664 - 2678
  • [49] Aggressive plaque modification with rotational atherectomy and cutting balloon for optimal stent expansion in calcified lesions
    Tang, Zhe
    Bai, Jing
    Su, Shao-Ping
    Lee, Pui-Wai
    Peng, Liang
    Zhang, Tao
    Sun, Ting
    Nong, Jing-Guo
    Li, Tian-De
    Wang, Yu
    JOURNAL OF GERIATRIC CARDIOLOGY, 2016, 13 (12) : 984 - 991
  • [50] Cutting balloons versus conventional balloons for treating patients with coronary artery disease presenting with moderate-to-severely calcified lesions: impact on post-interventional minimum stent area
    Tsujimura, Takuya
    Ishihara, Takayuki
    Takahashi, Kei
    Iida, Osamu
    Hata, Yosuke
    Toyoshima, Taku
    Higashino, Naoko
    Nakao, Sho
    Kurata, Naoya
    Mano, Toshiaki
    CARDIOVASCULAR INTERVENTION AND THERAPEUTICS, 2022, 37 (04) : 700 - 709