Impact of the Balloon Inflation Time and Pattern on the Coronary Stent Expansion

被引:5
|
作者
Skowronski, Jaroslaw [1 ]
Wolny, Rafal [1 ]
Jastrzebski, Jan [1 ]
Tyczynski, Pawel [1 ]
Szlazak, Karol [2 ]
Pregowski, Jerzy [1 ]
Mintz, Gary S. [3 ]
Lizewska, Karolina [2 ]
Swieszkowski, Wojciech [2 ]
Chmielak, Zbigniew [1 ]
Witkowski, Adam [1 ]
机构
[1] Inst Cardiol, Dept Intervent Cardiol & Angiol, Warsaw, Poland
[2] Warsaw Univ Technol, Fac Mat Sci & Engn, Warsaw, Poland
[3] Cardiovasc Res Fdn, New York, NY USA
关键词
OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; IMPLANTATION; THROMBOSIS; DEPLOYMENT; UNDEREXPANSION; OUTCOMES; IVUS;
D O I
10.1155/2019/6945372
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To assess the expansion pattern of coronary stents by using different balloon inflation times and pressures. Background. The selection of coronary stent size and its proper deployment is crucial in coronary artery interventions, having an impact on the success of the procedure and further therapy. Methods. Ten pairs of different stents were deployed under nominal pressure using sequential (5, 5, 10, and 10 seconds of repeated inflations, thus 30 seconds of summarized time) and continuous (30 seconds) deployment pattern. After each given time-point, intraluminal stent measurements were performed by optical coherence tomography (OCT) and intravascular ultrasound (IVUS). Results. Both in-stent diameters and cross-section areas (CSA) of paired stents measured by OCT at all sequential time-points were significantly smaller compared to given manufacturers charts' values (90% to 94% for diameters and 81% to 88% for CSA, p<0.05). Significant increase of in-stent diameter and CSA was observed across the step-by-step deployment pattern. In-stent lumen measurements were significantly larger when sequential deployment pattern was applied compared to continuous deployment. Additional measurements were also done for overlapping segments of stents, showing smaller in-stent measurements of the latter compared to nonoverlapping segments. Validation of OCT and IVUS measurements using a phantom metallic tube showed perfect reproducibility with OCT and overestimation with IVUS (8% for diameters and 16% for CSA). Conclusions. Stent diameter after deployment is time-dependent and not only pressure-dependent. Different stent expansion behavior, depending on the applied deployment pattern (sequential and nonsequential), was observed.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Duration of balloon inflation for optimal stent deployment: Five Seconds Is Not Enough
    Hovasse, Thomas
    Mylotte, Darren
    Garot, Philippe
    Salvatella, Neus
    Morice, Marie-Claude
    Chevalier, Bernard
    Pichard, Augusto
    Lefevre, Thierry
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (03) : 446 - 453
  • [22] Association between coronary artery calcium score and stent expansion in percutaneous coronary intervention
    Komaki, Soichi
    Ishii, Masanobu
    Ikebe, Sou
    Kaichi, Ryota
    Mori, Takayuki
    Marume, Kyohei
    Kurogi, Kazumasa
    Yamamoto, Nobuyasu
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 334 : 31 - 36
  • [23] Cutting balloon inflation for drug-eluting stent underexpansion due to unrecognized coronary arterial calcification
    Wilson, Andrew
    Ardehali, Reza
    Brinton, Todd J.
    Yeung, Alan C.
    Lee, David P.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2006, 7 (03) : 185 - 188
  • [24] Optimal stent positioning in coronary arteries: Partial balloon inflation to overcome cardiac cycle-related motion of the stent/delivery system
    Webster, MWI
    Dixon, SR
    Ormiston, JA
    Ruygrok, PN
    Stewart, JT
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 49 (01) : 102 - 104
  • [25] Kissing Balloon Inflation in Percutaneous Coronary Interventions
    Sgueglia, Gregory A.
    Chevalier, Bernard
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (08) : 803 - 811
  • [26] Paclitaxel-Coated Balloon vs Uncoated Balloon for Coronary In-Stent Restenosis
    Yeh, Robert W.
    Shlofmitz, Richard
    Moses, Jeffrey
    Bachinsky, William
    Dohad, Suhail
    Rudick, Steven
    Stoler, Robert
    Jefferson, Brian K.
    Nicholson, William
    Altman, John
    Bateman, Cinthia
    Krishnaswamy, Amar
    Grantham, J. Aaron
    Zidar, Frank J.
    Marso, Steven P.
    Tremmel, Jennifer A.
    Grines, Cindy
    Ahmed, Mustafa I.
    Latib, Azeem
    Tehrani, Behnam
    Abbott, J. Dawn
    Batchelor, Wayne
    Underwood, Paul
    Allocco, Dominic J.
    Kirtane, Ajay J.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2024, 331 (12): : 1015 - 1024
  • [27] Impact of Coronary Stent Design in Proximal Balloon Edge Dilation Technique for Bifurcation Percutaneous Coronary Intervention
    Kume, Teruyoshi
    Koto, Satoshi
    Murasato, Yoshinobu
    Yamada, Ryotaro
    Koyama, Terumasa
    Tamada, Tomoko
    Imai, Koichiro
    Okamoto, Hiroshi
    Sudo, Yasuyuki
    Enzan, Ayano
    Neishi, Yoji
    Uemura, Shiro
    INTERNATIONAL HEART JOURNAL, 2021, 62 (05) : 1106 - 1111
  • [28] Impact of coronary bifurcation angle on stent malapposition in a randomized comparison between proximal optimization technique followed by side branch dilatation and kissing balloon inflation
    Yamawaki, Masahiro
    Murasato, Yoshinobu
    Watanabe, Yusuke
    Kinoshita, Yoshihisa
    Okubo, Munenori
    Yumoto, Kazuhiko
    Masuda, Naoki
    Otake, Hiromasa
    Aoki, Jiro
    Nakazawa, Gaku
    Numasawa, Yohei
    Ito, Tatsuya
    Shite, Junya
    Okamura, Takayuki
    Takagi, Kensuke
    Kozuma, Kayoko
    Lefevre, Thierry
    Chevalier, Bernard
    Louvard, Yves
    Suzuki, Nobuaki
    Kozuma, Ken
    IJC HEART & VASCULATURE, 2023, 48
  • [29] Clinical impact of a new optical coherence tomography-derived volumetric method for evaluating stent expansion
    Kawamura, Akito
    Nakamura, Daisuke
    Shutta, Ryu
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Okamoto, Naotaka
    Egami, Yasuyuki
    Sakata, Yasushi
    Nishino, Masami
    Tanouchi, Jun
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (04) : 1121 - 1129
  • [30] Impact of final kissing balloon inflation after simple stent implantation for the treatment of non-left main true coronary bifurcation lesions in patients with acute coronary syndrome
    Kim, Tae-Hoon
    Lee, Hyun Jong
    Jang, Ho-Jun
    Kim, Je Sang
    Park, Jin Sik
    Choi, Rak Kyeong
    Choi, Young Jin
    Shim, Won-Heum
    Ro, Young Moo
    Yu, Cheol Woong
    Kwon, SungWoo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (03) : 907 - 911