Impact of the Balloon Inflation Time and Pattern on the Coronary Stent Expansion

被引:5
|
作者
Skowronski, Jaroslaw [1 ]
Wolny, Rafal [1 ]
Jastrzebski, Jan [1 ]
Tyczynski, Pawel [1 ]
Szlazak, Karol [2 ]
Pregowski, Jerzy [1 ]
Mintz, Gary S. [3 ]
Lizewska, Karolina [2 ]
Swieszkowski, Wojciech [2 ]
Chmielak, Zbigniew [1 ]
Witkowski, Adam [1 ]
机构
[1] Inst Cardiol, Dept Intervent Cardiol & Angiol, Warsaw, Poland
[2] Warsaw Univ Technol, Fac Mat Sci & Engn, Warsaw, Poland
[3] Cardiovasc Res Fdn, New York, NY USA
关键词
OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; IMPLANTATION; THROMBOSIS; DEPLOYMENT; UNDEREXPANSION; OUTCOMES; IVUS;
D O I
10.1155/2019/6945372
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To assess the expansion pattern of coronary stents by using different balloon inflation times and pressures. Background. The selection of coronary stent size and its proper deployment is crucial in coronary artery interventions, having an impact on the success of the procedure and further therapy. Methods. Ten pairs of different stents were deployed under nominal pressure using sequential (5, 5, 10, and 10 seconds of repeated inflations, thus 30 seconds of summarized time) and continuous (30 seconds) deployment pattern. After each given time-point, intraluminal stent measurements were performed by optical coherence tomography (OCT) and intravascular ultrasound (IVUS). Results. Both in-stent diameters and cross-section areas (CSA) of paired stents measured by OCT at all sequential time-points were significantly smaller compared to given manufacturers charts' values (90% to 94% for diameters and 81% to 88% for CSA, p<0.05). Significant increase of in-stent diameter and CSA was observed across the step-by-step deployment pattern. In-stent lumen measurements were significantly larger when sequential deployment pattern was applied compared to continuous deployment. Additional measurements were also done for overlapping segments of stents, showing smaller in-stent measurements of the latter compared to nonoverlapping segments. Validation of OCT and IVUS measurements using a phantom metallic tube showed perfect reproducibility with OCT and overestimation with IVUS (8% for diameters and 16% for CSA). Conclusions. Stent diameter after deployment is time-dependent and not only pressure-dependent. Different stent expansion behavior, depending on the applied deployment pattern (sequential and nonsequential), was observed.
引用
收藏
页数:10
相关论文
共 50 条
  • [11] Impact of coronary stent designs on acute stent recoil
    Ota, Tomoyuki
    Ishii, Hideki
    Sumi, Takuya
    Okada, Takuya
    Murakami, Hisashi
    Suzuki, Susumu
    Kada, Kenji
    Tsuboi, Naoya
    Murohara, Toyoaki
    JOURNAL OF CARDIOLOGY, 2014, 64 (5-6) : 347 - 352
  • [12] Comparison of definitions of coronary artery reference sizes and effects on stent selection and evaluation of stent expansion
    Andreasen, Lene Nyhus
    Christiansen, Evald Hoj
    Mogensen, Lone Juul Hune
    Holm, Niels Ramsing
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (09) : 1825 - 1837
  • [13] Thrombotic occlusion of coronary stents after prolonged balloon inflation outside the stent
    Rozenman, Y
    Nassar, H
    Gotsman, MS
    JOURNAL OF INVASIVE CARDIOLOGY, 1997, 9 (05) : 355 - 358
  • [14] Mechanical performances of balloon post-dilation for improving stent expansion in calcified coronary artery: Computational and experimental investigations
    Dong, Pengfei
    Mozafari, Hozhabr
    Lee, Juhwan
    Gharaibeh, Yazan
    Zimin, Vladislav N.
    Dallan, Luis A. P.
    Bezerra, Hiram G.
    Wilson, David L.
    Gu, Linxia
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 121
  • [15] Acute stent recoil and optimal balloon inflation strategy: an experimental study using real-time optical coherence tomography
    Kitahara, Hideki
    Waseda, Katsuhisa
    Yamada, Ryotaro
    Otagiri, Kyuhachi
    Tanaka, Shigemitsu
    Kobayashi, Yuhei
    Okada, Kozo
    Kume, Teruyoshi
    Nakagawa, Kaori
    Teramoto, Tomohiko
    Ikeno, Fumiaki
    Yock, Paul G.
    Fitzgerald, Peter J.
    Honda, Yasuhiro
    EUROINTERVENTION, 2016, 12 (02) : E190 - E198
  • [16] Impact of Kissing Balloon Inflation on the Main Vessel Stent Volume, Area, and Symmetry After Side-Branch Dilation in Patients With Coronary Bifurcation Lesions
    Rahman, Shahid
    Leesar, Tara
    Cilingiroglu, Mehmet
    Effat, Mohamed
    Arif, Imran
    Helmy, Tarek
    Leesar, Massoud A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (09) : 923 - 931
  • [17] Outcome of prolonged balloon inflation for the management of coronary perforation
    Meguro, Kentaro
    Ohira, Hiroshi
    Nishikido, Toshiyuki
    Fujita, Masaki
    Chinen, Toshiya
    Kikuchi, Tatsuo
    Nakamura, Kentaro
    Keida, Takehiko
    JOURNAL OF CARDIOLOGY, 2013, 61 (3-4) : 206 - 209
  • [18] Clinical outcomes after final kissing balloon inflation compared with no final kissing balloon inflation in bifurcation lesions treated with a dedicated coronary bifurcation stent
    Grundeken, Maik J.
    Lesiak, Maciej
    Asgedom, Solomon
    Garcia, Eulogio
    Bethencourt, Armando
    Norell, Michael S.
    Damman, Peter
    Woudstra, Pier
    Koch, Karel T.
    Vis, M. Marije
    Henriques, Jose P.
    Tijssen, Jan G.
    Onuma, Yoshinobu
    Foley, David P.
    Bartorelli, Antonio L.
    Stella, Pieter R.
    de Winter, Robbert J.
    Wykrzykowska, Joanna J.
    HEART, 2014, 100 (06) : 479 - 486
  • [19] Impact of stent deformity induced by the kissing balloon technique for bifurcating lesions on in-stent restenosis after coronary intervention
    Gamou, Tadatsugu
    Sakata, Kenji
    Terai, Hidenobu
    Horita, Yuki
    Ikeda, Masatoshi
    Namura, Masanobu
    Yamagishi, Masakazu
    Kawashiri, Masa-aki
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2018, 31 (04) : 421 - 429
  • [20] Longitudinal outcomes of final kissing balloon inflation in coronary bifurcation lesions treated with a single stent
    He, Lefan
    Robb, John F.
    Martinez-Camblor, Pablo
    Andrus, Bruce W.
    Greene, Lily J.
    Gongal, Prajesh
    Reddy, Dhruthi S.
    Devries, James T.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10