Impact of the Balloon Inflation Time and Pattern on the Coronary Stent Expansion

被引:5
|
作者
Skowronski, Jaroslaw [1 ]
Wolny, Rafal [1 ]
Jastrzebski, Jan [1 ]
Tyczynski, Pawel [1 ]
Szlazak, Karol [2 ]
Pregowski, Jerzy [1 ]
Mintz, Gary S. [3 ]
Lizewska, Karolina [2 ]
Swieszkowski, Wojciech [2 ]
Chmielak, Zbigniew [1 ]
Witkowski, Adam [1 ]
机构
[1] Inst Cardiol, Dept Intervent Cardiol & Angiol, Warsaw, Poland
[2] Warsaw Univ Technol, Fac Mat Sci & Engn, Warsaw, Poland
[3] Cardiovasc Res Fdn, New York, NY USA
关键词
OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND; IMPLANTATION; THROMBOSIS; DEPLOYMENT; UNDEREXPANSION; OUTCOMES; IVUS;
D O I
10.1155/2019/6945372
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. To assess the expansion pattern of coronary stents by using different balloon inflation times and pressures. Background. The selection of coronary stent size and its proper deployment is crucial in coronary artery interventions, having an impact on the success of the procedure and further therapy. Methods. Ten pairs of different stents were deployed under nominal pressure using sequential (5, 5, 10, and 10 seconds of repeated inflations, thus 30 seconds of summarized time) and continuous (30 seconds) deployment pattern. After each given time-point, intraluminal stent measurements were performed by optical coherence tomography (OCT) and intravascular ultrasound (IVUS). Results. Both in-stent diameters and cross-section areas (CSA) of paired stents measured by OCT at all sequential time-points were significantly smaller compared to given manufacturers charts' values (90% to 94% for diameters and 81% to 88% for CSA, p<0.05). Significant increase of in-stent diameter and CSA was observed across the step-by-step deployment pattern. In-stent lumen measurements were significantly larger when sequential deployment pattern was applied compared to continuous deployment. Additional measurements were also done for overlapping segments of stents, showing smaller in-stent measurements of the latter compared to nonoverlapping segments. Validation of OCT and IVUS measurements using a phantom metallic tube showed perfect reproducibility with OCT and overestimation with IVUS (8% for diameters and 16% for CSA). Conclusions. Stent diameter after deployment is time-dependent and not only pressure-dependent. Different stent expansion behavior, depending on the applied deployment pattern (sequential and nonsequential), was observed.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Effect of balloon inflation time on expansion of sirolimus-eluting stent
    Asano, Tatsuhiko
    Kobayashi, Yoshio
    Fukushima, Kenichi
    Iwata, Yo
    Kitahara, Hideki
    Ishio, Naoki
    Nakayama, Takashi
    Kuroda, Nakabumi
    Komuro, Issei
    HEART AND VESSELS, 2009, 24 (05) : 335 - 339
  • [2] Better stent expansion by two-time inflation of stent balloon and its responsible mechanism
    Iwamoto, Yumiko
    Okamoto, Mitsunori
    Hashimoto, Masaki
    Fukuda, Yukihiro
    Iwamoto, Akimichi
    Iwasaki, Toshitaka
    Kinoshita, Hiroki
    Kihara, Yasuki
    JOURNAL OF CARDIOLOGY, 2012, 59 (02) : 160 - 166
  • [3] Better Inflation Time of Stent Balloon for Second-Generation Drug-Eluting Stent Expansion and Apposition: An Optical Coherence Tomography Study
    Ann, Soe Hee
    Chung, Jae-Wook
    Jin, Cai De
    Lee, Jun Ho
    Kim, Jong Min
    Garg, Scot
    Shin, Eun-seok
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2014, 27 (02) : 171 - 176
  • [4] Improved stent expansion with prolonged compared with short balloon inflation: A meta-analysis
    Saad, Marwan
    Bavineni, Mahesh
    Uretsky, Barry F.
    Vallurupalli, Srikanth
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (05) : 873 - 880
  • [5] Impact of a Prolonged Delivery Inflation Time for Optimal Drug-Eluting Stent Expansion
    Kawasaki, Tomohiro
    Koga, Hisashi
    Serikawa, Takeshi
    Orita, Yoshiya
    Ikeda, Shinsuke
    Mito, Takahiro
    Gotou, Yoshitaka
    Shintani, Yoshiaki
    Tanaka, Atsushi
    Tanaka, Hidenori
    Fukuyama, Takaya
    Koga, Nobuhiko
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (02) : 205 - 211
  • [6] Coronary Stent Implantation Technique: Prolonged Inflation Time Maximizes Stent Expansion
    Saha, Mrinal
    Poliacikova, Petra
    de Belder, Adam
    Holmberg, Stephen
    Clarke, Michael
    Rajani, Ronak
    Hildick-Smith, David
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (01) : 28 - 31
  • [7] Effect of balloon inflation time on expansion of sirolimus-eluting stent
    Tatsuhiko Asano
    Yoshio Kobayashi
    Kenichi Fukushima
    Yo Iwata
    Hideki Kitahara
    Naoki Ishio
    Takashi Nakayama
    Nakabumi Kuroda
    Issei Komuro
    Heart and Vessels, 2009, 24 : 335 - 339
  • [8] Impact of Target Lesion Coronary Calcification on Stent Expansion - An Optical Coherence Tomography Study
    Kobayashi, Yuhei
    Okura, Hiroyuki
    Kume, Teruyoshi
    Yamada, Ryotaro
    Kobayashi, Yukari
    Fukuhara, Kenzo
    Koyama, Terumasa
    Nezuo, Shintaro
    Neishi, Yoji
    Hayashida, Akihiro
    Kawamoto, Takahiro
    Yoshida, Kiyoshi
    CIRCULATION JOURNAL, 2014, 78 (09) : 2209 - 2214
  • [9] Optical coherence tomography-verified longer balloon inflation time may provide better stent apposition and optimal index parameters
    Tasar, O.
    Karabay, A. K.
    Karabay, C. Yucel
    Kalkan, S.
    Cinier, G.
    Tanboga, I. H.
    Izgi, A. I.
    Kirma, C.
    HERZ, 2020, 45 (04) : 369 - 374
  • [10] Stent expansion in calcified coronary chronic total occlusions: The impact of different stent platforms
    Scarparo, Paola
    Schermers, Thom
    Improta, Riccardo
    Kardys, Isabella
    Wilschut, Jeroen
    Daemen, Joost
    Nuis, Rutger-Jan
    Den Dekker, Wijnand K. K.
    Van Mieghem, Nicolas M. M.
    Diletti, Roberto
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (03) : 451 - 463