Long-term changes in intraocular lens position and corneal curvature after cataract surgery and their effect on refraction

被引:16
作者
Klijn, Stijn [1 ]
Sicam, Victor Arni D. P. [1 ]
Reus, Nicolaas J. [1 ,2 ]
机构
[1] Rotterdam Ophthalm Inst, POB 70030, NL-3000 LM Rotterdam, Netherlands
[2] Amphia Hosp, Dept Ophthalmol, Breda, Netherlands
关键词
PARTIAL COHERENCE INTERFEROMETRY; POWER CALCULATIONS; BIOMETRY; KERATOMETRY; ANTERIOR; SURFACE; DESIGN;
D O I
10.1016/j.jcrs.2015.08.015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the role of intraocular lens (IOL) position shift and changes in corneal curvature on long-term refractive shift after cataract surgery. SETTING: Rotterdam Ophthalmic Institute, Rotterdam, the Netherlands. DESIGN: Prospective cohort study. METHODS: Patients who had routine cataract surgery with implantation of a hydrophobic acrylic 1-piece IOL (Acrysof SA60AT) in the capsular bag were enrolled. Measurements were performed preoperatively and 1 month, 3 months, and 1 year postoperatively. Refraction was measured with the ARK-530A autorefractor. The IOL position and corneal curvature were measured with the Lenstar LS-900 biometer. The refractive effect of changes in IOL position and corneal curvature was calculated with a Gaussian optics-based thin-lens formula and correlated with the measured refractive shift. RESULTS: The study group comprised 59 eyes of 59 patients. The median measured absolute refractive change was 0.25 diopter (D). The IOL position showed a statistically significant mean posterior shift of 0.033 mm +/- 0.060 (SD) between 1 month and 1 year postoperatively (P < .01), of which the median calculated absolute refractive effect was 0.05 D. This did not correlate with the measured refractive shift (Pearson r = 0.10, P = .46). Natural fluctuations in corneal curvature caused a median calculated absolute refractive effect of 0.17 D, which correlated well with the measured refractive shift (Pearson r = .55, P < .001). CONCLUSIONS: Long-term changes in refraction after cataract surgery resulted from natural fluctuations in corneal curvature rather than from IOL position shift. These fluctuations limit the accuracy with which the refractive outcome can be planned.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 24 条
[1]  
Bland JM, 1996, BRIT MED J, V313, P744
[2]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[3]  
Corydon L, 1993, EUR J IMPLANT REFRAC, V5, P51
[4]   Evaluation of the Lenstar LS 900 non-contact biometer [J].
Cruysberg, L. P. J. ;
Doors, M. ;
Verbakel, F. ;
Berendschot, T. T. J. M. ;
De Brabander, J. ;
Nuijts, R. M. M. A. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (01) :106-110
[5]   Partial coherence interferometry: A novel approach to biometry in cataract surgery [J].
Drexler, W ;
Findl, O ;
Menapace, R ;
Rainer, G ;
Vass, C ;
Hitzenberger, CK ;
Fercher, AF .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (04) :524-534
[6]   The shape of the anterior and posterior surface of the aging human cornea [J].
Dubbelman, M ;
Sicarn, VADP ;
Van der Heijde, GL .
VISION RESEARCH, 2006, 46 (6-7) :993-1001
[7]  
DUNNE MCM, 1992, ACTA OPHTHALMOL, V70, P255
[8]   Validity of the keratometric index: Evaluation by the Pentacam rotating Scheimpflug camera [J].
Ho, Jau-Der ;
Tsai, Ching-Yao ;
Tsai, Ray Jui-Fang ;
Kuo, Li-Lin ;
Tsai, I-Lun ;
Liou, Shiow-Wen .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (01) :137-145
[9]  
Hoffer KJ, 2007, J CATARACT REFR SURG, V33, P2, DOI 10.1016/j.jcrs.2006.08.054
[10]  
HOFFER KJ, 1994, J CATARACT REFR SURG, V20, P677