Platelet aggregation and activation under complex patterns of shear stress

被引:62
作者
Zhang, JN
Bergeron, AL
Yu, QH
Sun, C
McIntire, LV
López, JA
Dong, JF
机构
[1] Baylor Coll Med, Dept Med, Thrombosis Res Sect, Div Thrombosis Res, Houston, TX 77030 USA
[2] Baylor Coll Med, Dept Mol & Human Genet, Houston, TX 77030 USA
[3] Rice Univ, Cox Lab Bioengn, Houston, TX 77251 USA
关键词
shear stress; stenosis; platelets activation; aggregation;
D O I
10.1055/s-0037-1613308
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Arterial stenoasis results in a complex pattern of blood flow containing an extremely fast flow in the throat of stenosis and a post-stenosis low flow. The fast flow generates high shear stress that has been demonstrated in vitro to activate and aggregate platelets. One potential problem of these in vitro studies is that platelets are invariably exposed to a high shear stress for a period that is significantly longer than they would have experienced in vivo. More importantly, the role of the post-stenosis low flow in platelet activation and aggregation has not been determined. By exposing platelets to a shear profile that contains both high and low shear segments, we found that platelets aggregate when they are exposed to a high shear stress of 100 dyn/cm(2) for as short as 2.5 s, a period that is significantly shorter than those previously reported (30-120 s). Platelet aggregation under this condition requires a low shear exposure immediately after a high shear pulse, suggesting that post-stenosis low flow enhances platelet aggregation. Furthermore, platelet aggregation under this condition is not activation-dependent because the CD62P expression of sheared platelets is significantly less than that of platelets treated with ADP. Based on these findings, we propose that shear-induced platelet aggregation may be a process of mechanical crosslinking of platelets, requiring minimal platelet activation. This process may function as a protective mechanism to prevent in vivo irreversible platelet activation and aggregation under temporary high shear.
引用
收藏
页码:817 / 821
页数:5
相关论文
共 25 条
  • [1] PULSATILE POSTSTENOTIC FLOW STUDIES WITH LASER DOPPLER ANEMOMETRY
    AHMED, SA
    GIDDENS, DP
    [J]. JOURNAL OF BIOMECHANICS, 1984, 17 (09) : 695 - &
  • [2] Physiological flow simulation in residual human stenoses after coronary angioplasty
    Banerjee, RK
    Back, LH
    Back, MR
    Cho, YI
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (04): : 310 - 320
  • [3] Fluid mechanics of arterial stenosis: Relationship to the development of mural thrombus
    Bluestein, D
    Niu, LJ
    Schoephoerster, RT
    Dewanjee, MK
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 1997, 25 (02) : 344 - 356
  • [4] Assessment of arterial stenosis in a flow model with power Doppler angiography: Accuracy and observations on blood echogenicity
    Cloutier, G
    Qin, Z
    Garcia, D
    Soulez, G
    Oliva, V
    Durand, LG
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2000, 26 (09) : 1489 - 1501
  • [5] Experimental and numerical study of pulsatile flows through stenosis: Wall shear stress analysis
    Deplano, V
    Siouffi, M
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (10) : 1081 - 1090
  • [6] Ristocetin-dependent, but not botrocetin-dependent, binding of von Willebrand factor to the platelet glycoprotein Ib-IX-V complex correlates with shear-dependent interactions
    Dong, JF
    Berndt, MC
    Schade, A
    McIntire, LV
    Andrews, RK
    López, JA
    [J]. BLOOD, 2001, 97 (01) : 162 - 168
  • [7] Shear-dependent rolling on von Willebrand factor of mammalian cells expressing the platelet glycoprotein Ib-IX-V complex
    Fredrickson, BJ
    Dong, JF
    McIntire, LV
    López, JA
    [J]. BLOOD, 1998, 92 (10) : 3684 - 3693
  • [8] BLOOD-FLOW AND THROMBOSIS
    GOLDSMITH, HL
    [J]. THROMBOSIS ET DIATHESIS HAEMORRHAGICA, 1974, 32 (01): : 35 - 48
  • [9] Enhanced shear-induced platelet aggregation in acute myocardial infarction
    Goto, S
    Sakai, H
    Goto, M
    Ono, M
    Ikeda, Y
    Handa, S
    Ruggeri, ZM
    [J]. CIRCULATION, 1999, 99 (05) : 608 - 613
  • [10] MR flow measurement in the internal mammary artery-to-coronary artery bypass graft: Comparison with graft stenosis at radiographic angiography
    Ishida, N
    Sakuma, H
    Cruz, BP
    Shimono, T
    Tokui, T
    Yada, I
    Takeda, K
    Higgins, CB
    [J]. RADIOLOGY, 2001, 220 (02) : 441 - 447