Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer

被引:33
作者
Gao, Feng [1 ]
Liu, Hu [1 ]
Zhao, Qing [1 ]
Pan, Yingzhe [1 ]
机构
[1] Hubei Univ Med, Peoples Hosp Xiangyang 1, Dept Ophthalmol, 15 Jiefang Rd, Xiangyang 441000, Hubei, Peoples R China
关键词
iCare rebound tonometer; Goldmann applanation tonometry; intraocular pressure; central corneal thickness; CENTRAL CORNEAL THICKNESS; INTRAOCULAR-PRESSURE; GLAUCOMA;
D O I
10.3892/etm.2017.4164
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compare the intraocular pressure (IOP) results obtained using the RT and GAT and then correlate the results with the central corneal thickness (CCT). Moreover, the tolerability and safety of the RT were evaluated. The IOP of 336 patients (672 eyes) was determined by the RT and GAT. The patients were divided into three groups (group A, 7-15 mmHg, n=74; group B, 16-22 mmHg, n=218; and group C, 23-50 mmHg, n=44), based on the GAT IOP readings. Pachymetry and slit lamp inspection were also performed. To establish an agreement between the devices, a Bland-Altman analysis and paired t-test were performed. The correlation between CCT and IOP readings obtained by the two devices were assessed using linear regression correlation analysis. The mean IOP values of the RT and the GAT were 18.30 +/- 5.10 and 18.52 +/- 4.46 mmHg, respectively. There were no significant differences between them (t=-1.31, P=0.19). The 95% confidence interval of the differences between the two devices was -5.80-6.24 mmHg. The RT readings are correlated well with those of GAT (r=0.806, P=0.001). However, the RT measurements were significantly (t=-2.84, P=0.007) lower (-1.66 +/- 3.87 mmHg) than those obtained with GAT when GAT =23 mmHg. Both the RT (r=0.390, P=0.001) and the GAT (r=0.191, P=0.001) showed positive correlations with CCT. The IOP measurement with RT was well tolerated. None of the corneal epithelial defects was detected and all subjects denied discomfort. The RT is well tolerated and safe, and can be considered a reliable alternative to GAT for patients in a low to moderate IOP range. However, in patients with high IOP values, the measurements obtained with RT did not correlate well with those obtained by GAT. The RT readings are influenced more by CCT compared to GAT.
引用
收藏
页码:1912 / 1916
页数:5
相关论文
共 50 条
  • [41] Variations of Intraocular Pressure Measured by Goldmann Applanation Tonometer, Tono-Pen, iCare Rebound Tonometer, and Pascal Dynamic Contour Tonometer in Patients With Corneal Edema After Phacoemulsification
    Kiddee, Weerawat
    Tanjana, Arunee
    JOURNAL OF GLAUCOMA, 2021, 30 (04) : 317 - 324
  • [42] CLINICAL COMPARISON OF THE XPERT(TM) NONCONTACT TONOMETER AND THE CONVENTIONAL GOLDMANN APPLANATION TONOMETER
    HANSEN, MK
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1995, 73 (02): : 176 - 180
  • [43] Comparison of the transpalpebral tonometer TGDc-01 with Goldmann applanation tonometry
    Waisbourd, Michael
    Shemesh, Gabi
    Top, Lea Baras
    Lazar, Moshe
    Loewenstein, Anat
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2010, 20 (05) : 902 - 906
  • [44] Reliability of the Non-contact TONO-i Tonometer Compared with the Goldmann Applanation Tonometer
    Kim, Ji Ho
    Han, Jong Chul
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (05): : 416 - 422
  • [45] The Icare-Pro Rebound Tonometer Versus the Hand-held Applanation Tonometer in Congenital Glaucoma
    Borrego Sanz, Lara
    Morales-Fernandez, Laura
    Martinez de-la-Casa, Jose M.
    Saenz-Frances, Federico
    Fuentes, Manuel
    Garcia-Feijoo, Julian
    JOURNAL OF GLAUCOMA, 2016, 25 (02) : 149 - 154
  • [46] Comparison of the Proview pressure phosphene tonometer performed by the patient and examiner with the Goldmann applanation tonometer
    Danesh-Meyer, HV
    Niederer, R
    Gaskin, BJ
    Gamble, G
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2004, 32 (01) : 29 - 32
  • [47] Relationship of Central Corneal Thickness and Intraocular Pressure by iCare Rebound Tonometer
    Rao, Aparna
    Kumar, Mukesh
    Prakash, B.
    Varshney, Gopal
    JOURNAL OF GLAUCOMA, 2014, 23 (06) : 380 - 384
  • [48] Diagnostic accuracy of the iCare rebound tonometer compared to the Perkins applanation tonometer in assessing intraocular pressure in rural patients
    Li, Yifan
    Carpenter, Christopher R.
    Nicholson, Kathryn
    Milne, William Ken
    DIAGNOSIS, 2015, 2 (04) : 227 - 234
  • [49] Comparison of intraocular pressure measurements with the digital tonometer TGDc-01 'PRA' and the Goldmann applanation tonometer
    Meyer, MW
    Gockeln, R
    Hoy, L
    Meyer, A
    Erb, C
    OPHTHALMIC RESEARCH, 2004, 36 (05) : 250 - 254
  • [50] Assessment of a new Goldmann applanation tonometer
    Egli, M.
    Goldblum, D.
    Kipfer, A.
    Rohrer, K.
    Tappeiner, C.
    Abegg, M.
    Berger, L.
    Schoetzau, A.
    Iliev, M. E.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2012, 96 (01) : 42 - 46