Comparison of the iCare rebound tonometer and the Goldmann applanation tonometer

被引:33
作者
Gao, Feng [1 ]
Liu, Hu [1 ]
Zhao, Qing [1 ]
Pan, Yingzhe [1 ]
机构
[1] Hubei Univ Med, Peoples Hosp Xiangyang 1, Dept Ophthalmol, 15 Jiefang Rd, Xiangyang 441000, Hubei, Peoples R China
关键词
iCare rebound tonometer; Goldmann applanation tonometry; intraocular pressure; central corneal thickness; CENTRAL CORNEAL THICKNESS; INTRAOCULAR-PRESSURE; GLAUCOMA;
D O I
10.3892/etm.2017.4164
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Tonometry is a fundamental procedure in routine ophthalmologic examination. Although regarded as the reference standard, the Goldmann applanation tonometer (GAT) has its limitations. A new portable alternative to the GAT is the iCare rebound tonometer (RT). The aim of the present study was to compare the intraocular pressure (IOP) results obtained using the RT and GAT and then correlate the results with the central corneal thickness (CCT). Moreover, the tolerability and safety of the RT were evaluated. The IOP of 336 patients (672 eyes) was determined by the RT and GAT. The patients were divided into three groups (group A, 7-15 mmHg, n=74; group B, 16-22 mmHg, n=218; and group C, 23-50 mmHg, n=44), based on the GAT IOP readings. Pachymetry and slit lamp inspection were also performed. To establish an agreement between the devices, a Bland-Altman analysis and paired t-test were performed. The correlation between CCT and IOP readings obtained by the two devices were assessed using linear regression correlation analysis. The mean IOP values of the RT and the GAT were 18.30 +/- 5.10 and 18.52 +/- 4.46 mmHg, respectively. There were no significant differences between them (t=-1.31, P=0.19). The 95% confidence interval of the differences between the two devices was -5.80-6.24 mmHg. The RT readings are correlated well with those of GAT (r=0.806, P=0.001). However, the RT measurements were significantly (t=-2.84, P=0.007) lower (-1.66 +/- 3.87 mmHg) than those obtained with GAT when GAT =23 mmHg. Both the RT (r=0.390, P=0.001) and the GAT (r=0.191, P=0.001) showed positive correlations with CCT. The IOP measurement with RT was well tolerated. None of the corneal epithelial defects was detected and all subjects denied discomfort. The RT is well tolerated and safe, and can be considered a reliable alternative to GAT for patients in a low to moderate IOP range. However, in patients with high IOP values, the measurements obtained with RT did not correlate well with those obtained by GAT. The RT readings are influenced more by CCT compared to GAT.
引用
收藏
页码:1912 / 1916
页数:5
相关论文
共 50 条
  • [31] Comparison of Disposable Goldmann Applanation Tonometer, ICare ic100, and Tonopen XL to Standards of Care Goldmann Nondisposable Applanation Tonometer for Measuring Intraocular Pressure
    Wong, Benny
    Parikh, Deep
    Rosen, Lisa
    Gorski, Matthew
    Angelilli, Allison
    Shih, Carolyn
    JOURNAL OF GLAUCOMA, 2018, 27 (12) : 1119 - 1124
  • [32] Comparison of the IOPen® and iCare® rebound tonometers with the Goldmann tonometer in a normal population
    Jorge, J.
    Fernandes, P.
    Queiros, A.
    Ribeiro, P.
    Garces, C.
    Gonzalez-Meijome, J. M.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2010, 30 (01) : 108 - 112
  • [33] COMPARISON OF A NEW TONOMETER (PROTON) WITH THE GOLDMANN APPLANATION TONOMETER
    GRAF, M
    WASSILL, H
    DICK, B
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1995, 206 (04) : 255 - 261
  • [34] Comparability of Icare Pro Rebound Tonometer with Goldmann Applanation and Noncontact Tonometer in a Wide Range of Intraocular Pressure and Central Corneal Thickness
    Tamcelik, Nevbahar
    Atalay, Eray
    Cicik, Erdogan
    Ozkok, Ahmet
    OPHTHALMIC RESEARCH, 2015, 54 (01) : 18 - 25
  • [35] Comparison of ICare Rebound Tonometer With Noncontact Tonometer in Healthy Children
    Kageyama, Mitsuyo
    Hirooka, Kazuyuki
    Baba, Tetsuya
    Shiraga, Fumio
    JOURNAL OF GLAUCOMA, 2011, 20 (01) : 63 - 66
  • [36] Vergleich des iCare-Tonometers mit dem Goldmann-Tonometer in MalawiComparison of the iCare tonometer with the Goldmann tonometer in Malawi
    J. Hohmann
    M. Schulze-Schwering
    T. Chirambo Nyaka
    V. Moyo
    P.C. Kayange
    D. Doycheva
    N.H. Batumba
    M.S. Spitzer
    Der Ophthalmologe, 2012, 109 : 1098 - 1102
  • [37] The iCare rebound tonometer: comparisons with Goldmann tonometry, and influence of central corneal thickness
    Poostchi, Ali
    Mitchell, Robert
    Nicholas, Simon
    Purdie, Gordon
    Wells, Anthony
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2009, 37 (07) : 687 - 691
  • [38] A comparison of postural and diurnal variations in intraocular pressure using the iCare rebound tonometer and Perkins applanation tonometer in admitted adults in Kenya
    Chikasirimobi, Timothy G.
    Ndinyo, Mercy
    Ondieki, Maxine N.
    Miti, Isaac
    Ejiochi-Iyoke, Ndidi J.
    Osuagwu, Uchechukwu L.
    Zeried, Ferial M.
    Agho, Kingsley
    Ogbuehi, Kelechi C.
    Mashige, Khathutshelo P.
    AFRICAN VISION AND EYE HEALTH JOURNAL, 2021, 80 (01):
  • [39] Comparison of the Icare rebound tonometry with the Goldmann applanation tonometry in a pediatric population
    Grigorian, Florin
    Grigorian, A. Paula
    Li, Ang
    Sattar, Abdus
    Krishna, Rohit
    Olitsky, Scott E.
    JOURNAL OF AAPOS, 2015, 19 (06): : 572 - 574
  • [40] Clinical Evaluation of the New Rebound Tonometers Icare PRO and Icare ONE Compared With the Goldmann Tonometer
    Moreno-Montanes, Javier
    Martinez-de-la-Casa, Jose M.
    Sabater, Alfonso L.
    Morales-Fernandez, Laura
    Saenz, Cristina
    Garcia-Feijoo, Julian
    JOURNAL OF GLAUCOMA, 2015, 24 (07) : 527 - 532