Performance prediction for solar air heater having rectangular sectioned tapered rib roughness using CFD

被引:54
作者
Gupta, A. D. [1 ]
Varshney, L. [1 ]
机构
[1] GB Pant Univ Agr & Technol, Dept Mech Engn, Pantnagar 263145, Uttar Pradesh, India
关键词
Solar air heater; Artificial roughness; Heat transfer enhancement; Computational fluids dynamics;
D O I
10.1016/j.tsep.2017.09.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the present work CFD analysis of a solar air heater (SAH) duct provided with artificial roughness in the form of rectangular sectioned tapered rib has been performed using Ansys FLUENT. Twelve different configurations of tapered rib with taper angle, alpha(t) of 1.6 degrees, 2.3 degrees and 3.2 degrees for pitch of 10, 15, 20 and 25 mm and constant rib width, w(r) = 0.7 mm have been considered as roughness element. A three-dimensional nonuniform hybrid grid is generated according to the configuration using cutcell method. The differential equations involved in the model are solved with a finite-volume-based numerical method. The RNG k-e turbulence model with enhanced wall function is used to solve the transport equations for turbulent flow and energy dissipation rate. Effect of roughness parameters namely tapered angle and relative roughness pitch on Nusselt number and friction factor for a constant value of heat flux (1000 W/m(2)) is discussed. The optimal values of geometrical parameters are obtained on the basis of the performance index in the range of Reynolds number 3800-18,000. Optimum performance index is found to be 1.91 corresponding to the alpha(t) of 1.6 degrees and relative roughness pitch, P/e of 10.7 at Reynolds number, Re of 12,000. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:122 / 132
页数:11
相关论文
共 40 条
[1]   Heat transfer enhancement in solar air heater duct with conical protrusion roughness ribs [J].
Alam, Tabish ;
Kim, Man-Hoe .
APPLIED THERMAL ENGINEERING, 2017, 126 :458-469
[2]   Thermal performance of an air solar collector with an absorber plate made of recyclable aluminum cans [J].
Alvarez, G ;
Arce, J ;
Lira, L ;
Heras, MR .
SOLAR ENERGY, 2004, 77 (01) :107-113
[3]  
[Anonymous], 2003, 93 ASHRAE
[4]  
[Anonymous], 2011, ANSYS FLUENT 14 0 US
[5]   A CFD heat transfer analysis of the transpired solar collector under no-wind conditions [J].
Arulanandam, SJ ;
Hollands, KGT ;
Brundrett, E .
SOLAR ENERGY, 1999, 67 (1-3) :93-100
[6]  
Bhatti MS., 1987, Handbook of SinglePhase Convective Heat Transfer
[7]   Effect of rib profiles on turbulent channel flow heat transfer [J].
Chandra, PR ;
Fontenot, ML ;
Han, JC .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1998, 12 (01) :116-118
[8]   Analysis of heat transfer augmentation and flow characteristics due to rib roughness over absorber plate of a solar air heater [J].
Chaube, A ;
Sahoo, PK ;
Solanki, SC .
RENEWABLE ENERGY, 2006, 31 (03) :317-331
[9]   Experimental and CFD investigation of convection heat transfer in solar air heater with reverse L-shaped ribs [J].
Gawande, Vipin B. ;
Dhoble, A. S. ;
Zodpe, D. B. ;
Chamoli, Sunil .
SOLAR ENERGY, 2016, 131 :275-295
[10]   Experimental and CFD-based thermal performance prediction of solar air heater provided with chamfered square rib as artificial roughness [J].
Gawande, Vipin B. ;
Dhoble, A. S. ;
Zodpe, D. B. ;
Chamoli, Sunil .
JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2016, 38 (02) :643-663