Comparative study of four retentive anchor systems for implant supported overdentures - retention force changes

被引:31
作者
Bayer, Stefan [1 ]
Steinheuser, Daniela [1 ]
Gruener, Manfred [1 ]
Keilig, Ludger [1 ,2 ]
Enkling, Norbert [3 ]
Stark, Helmut [1 ]
Mues, Sebastian [1 ]
机构
[1] Univ Bonn, Dept Prosthodont Preclin Educ & Dent Mat Sci, D-53111 Bonn, Germany
[2] Univ Bonn, Endowed Chair Oral Technol, D-53111 Bonn, Germany
[3] Univ Bern, Clin Prosthet Dent, Bern, Switzerland
关键词
dental implants; attachments; wear; ball anchor; overdenture; retention force; fatigue loading; gerostomatology; IN-VITRO; CONVENTIONAL DENTURES; ATTACHMENTS;
D O I
10.1111/j.1741-2358.2009.00286.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Wear of attachments leads to a loss of retention and potentially reduces the function of complete dentures. This study evaluated the retention force changes of different prefabricated attachment systems for implant-supported overdentures to estimate the wear constancy and applicability in clinical practice. Methods: Four prefabricated attachment systems were tested [Group SG: retentive ball attachment (Straumann, Switzerland) with gold matrix, Group ST: retentive ball attachment (Straumann, Switzerland) with titanium spring matrix, Group IB: UNOR i-Ball with Ecco matrix (UNOR, Switzerland) and Group IMZ: IMZ (R)-TwinPlus ball attachment with gold matrix (DENTSPLY Friadent, Germany)]. Ten samples of each system were subjected to 10 000 insertion-separation cycles. Results: Results showed that all types of attachments showed wear, which led to a loss of retention force after an initial increase at the beginning of the wear simulation. Attachments with a plastic retention insert or gold matrices underwent the smallest changes in retention force. The titanium spring system showed the largest changes in retention force and a greater variation between the different cycles and specimen. This behaviour is probably caused by a large fitting tolerance of the titanium spring. Conclusions: Attachment systems which possess a male and female component of different material composition are preferable. They show smaller changes in the retention force. For retention force increase and wear compensation, an attachment system should be adjustable.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 24 条
  • [1] A patient-based assessment of implant-stabilized and conventional complete dentures
    Allen, PF
    McMillan, AS
    Walshaw, D
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (02) : 141 - 147
  • [2] Awad MA, 2003, INT J PROSTHODONT, V16, P390
  • [3] BAYER S, 2003, DTSCH ZAHNARZTL Z, V58, pD4
  • [4] Bayer S, 2007, QUINTESSENCE INT, V38, pE229
  • [5] Becker H, 1983, Zahnarztl Prax, V34, P281
  • [6] In vitro retention force changes of prefabricated attachments for overdentures
    Besimo, CE
    Guarneri, A
    [J]. JOURNAL OF ORAL REHABILITATION, 2003, 30 (07) : 671 - 678
  • [7] Retention force and fatigue strength of overdenture attachment systems
    Botega, DM
    Mesquita, MF
    Henriques, GEP
    Vaz, LG
    [J]. JOURNAL OF ORAL REHABILITATION, 2004, 31 (09) : 884 - 889
  • [8] Donatsky O, 1993, Int J Oral Maxillofac Implants, V8, P162
  • [9] In vivo forces on oral implants supporting a mandibular overdenture: the influence of attachment system.
    Duyck J.
    Van Oosterwyck H.
    Vander Sloten J.
    De Cooman M.
    Puers R.
    Naert I.
    [J]. Clinical Oral Investigations, 1999, 3 (4) : 201 - 207
  • [10] Development of a periodontium-approximated specimen holder for attritional investigations of telescopic crowns
    Grüner, M
    Bourauel, C
    Keilig, L
    Utz, KH
    Stark, H
    [J]. BIOMEDIZINISCHE TECHNIK, 2003, 48 (1-2): : 15 - 19