Evaluation of impression accuracy for osseointegrated implant supported superstructures

被引:111
作者
Herbst, D [1 ]
Nel, JC [1 ]
Driessen, CH [1 ]
Becker, PJ [1 ]
机构
[1] Univ Pretoria, Dept Restorat Dent, Fac Dent, ZA-0001 Pretoria, South Africa
关键词
D O I
10.1016/S0022-3913(00)70014-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. An often-debated issue still exists concerning implant impression techniques, whether to splint impression copings. Different configurations are available for these copings for a variety of manufactures' implant systems. Purpose, This study evaluated and compared 4 impression techniques in terms of their dimensional accuracy to reproduce implant positions on working casts. Material and methods. A master model was designed to simulate ii clinical situation. Impressions were made using 4 techniques: (1) tapered impression copings trot splinted; (2) squared impression copings not splinted; (3) squared impression copings splinted with autopolymerizing acrylic resin; and (4) squared impression copings with a lateral extension on one side not splinted. Reference points machined onto the master model and onto special healing abutments were compared after abutments were transferred to casts using the 4 techniques. Measurements were made using a Reflex microscope, capable of recording in the x-, y-, and z-dimensions. Results. The dimensional accuracy was high and, although statistically significant (P=.022; power > 80%), a maximum distortion difference of only 0.31% was registered. Conclusion. The dimensional accuracy of all the techniques was exceptional and the observed differences can be regarded as clinically negligible.
引用
收藏
页码:555 / 561
页数:7
相关论文
共 40 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]  
Assif D, 1996, Int J Oral Maxillofac Implants, V11, P216
[3]   A MODIFIED IMPRESSION TECHNIQUE FOR IMPLANT-SUPPORTED RESTORATION [J].
ASSIF, D ;
MARSHAK, B ;
NISSAN, J .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (06) :589-591
[4]  
Assif D, 1992, INT J PERIODONT REST, V12, P113
[5]  
AUGSBURGER RH, 1981, OPER DENT, V6, P70
[6]  
Barrett M G, 1993, J Prosthodont, V2, P75
[7]  
Branemark P.I., 1985, TISSUE INTEGRATED PR, P253
[8]   TIGHTENING CHARACTERISTICS FOR SCREWED JOINTS IN OSSEOINTEGRATED DENTAL IMPLANTS [J].
BURGUETE, RL ;
JOHNS, RB ;
KING, T ;
PATTERSON, EA .
JOURNAL OF PROSTHETIC DENTISTRY, 1994, 71 (06) :592-599
[9]  
Carr A B, 1991, Int J Oral Maxillofac Implants, V6, P448
[10]  
Carr A B, 1992, Int J Oral Maxillofac Implants, V7, P468