Test-retest reliability of glenohumeral internal and external rotator strength

被引:57
作者
Plotnikoff, NA [1 ]
MacIntyre, DL [1 ]
机构
[1] Univ British Columbia, Sch Rehabil Sci, Vancouver, BC V6T 2B5, Canada
来源
CLINICAL JOURNAL OF SPORT MEDICINE | 2002年 / 12卷 / 06期
关键词
shoulder; isokinetic; reliability;
D O I
10.1097/00042752-200211000-00008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To establish test-retest reliability for a strength testing protocol of the glenohumeral internal and external rotator muscles using a KinCom (Chattanooga Group, Hixson, TN) isokinetic dynamometer. Design: Prospective test-retest reliability study. Setting: Rehabilitation research laboratory. Participants: Fourteen volunteers between the ages of 27 and 35 years participated in the study. Subjects had no history of traumatic shoulder injury and no overuse-based shoulder pain interfering with activity within the last 6 months. Nine of the 14 subjects were not participating in more than 6 hours weekly of arm-based sporting activities, while the remaining five subjects were involved in swim training at workout volumes of no greater than 3000 in per week. Intervention: Subjects performed three test sessions of four maximal repetitions each of concentric and eccentric shoulder internal and external rotation bilaterally in a standardized sitting position. An average of 5.9 days occurred between consecutive test sessions (range, 2-21 days). Main Outcome Measures: Average torque data were collected for concentric and eccentric internal and external rotation tests bilaterally. Intraclass correlation coefficients were calculated to compare the data across sessions. Pearson product moment correlation coefficients were calculated to assess reliability between sessions. Results: High test-retest reliability, ranging from 0.82 to 0.97, was demonstrated for all tests. Conclusions: The results indicate that a reliable test protocol has been determined for shoulder internal and external rotation strength testing on the KinCom isokinetic dynamometer.
引用
收藏
页码:367 / 372
页数:6
相关论文
共 27 条
[21]  
PENTLAND WE, 1993, ISOKINET EXERC SCI, V3, P88
[22]  
SODERBERG G J, 1987, Journal of Orthopaedic and Sports Physical Therapy, V8, P518
[23]  
WALMSLEY R P, 1987, Journal of Orthopaedic and Sports Physical Therapy, V9, P217
[24]   PATTERNS OF FLEXIBILITY, LAXITY, AND STRENGTH IN NORMAL SHOULDERS AND SHOULDERS WITH INSTABILITY AND IMPINGEMENT [J].
WARNER, JJP ;
MICHELI, LJ ;
ARSLANIAN, LE ;
KENNEDY, J ;
KENNEDY, R .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1990, 18 (04) :366-375
[25]   A COMPARISON OF TORQUE PRODUCTION DURING DYNAMIC STRENGTH TESTING OF SHOULDER ABDUCTION IN THE CORONAL PLANE AND THE PLANE OF THE SCAPULA [J].
WHITCOMB, LJ ;
KELLEY, MJ ;
LEIPER, CI .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1995, 21 (04) :227-232
[26]   THE STRENGTH CHARACTERISTICS OF INTERNAL AND EXTERNAL ROTATOR MUSCLES IN PROFESSIONAL BASEBALL PITCHERS [J].
WILK, KE ;
ANDREWS, JR ;
ARRIGO, CA ;
KEIRNS, MA ;
ERBER, DJ .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (01) :61-66
[27]  
WILK KE, 1991, ISOKINET EXERC SCI, V1, P63