The validation of immunoblot SDS-PAGE as a qualitative and quantitative method for the determination of urinary Cystatin C in neonates

被引:7
作者
Grasselli, Chiara [1 ]
Barbati, Antonella [1 ]
Cesarini, Lucia [2 ]
Pellegrino, Roberto [2 ]
Di Renzo, Gian Carlo [1 ,3 ]
机构
[1] Univ Perugia, Sect Obstet & Gynecol, Dept Surg & Biomed Sci, Perugia, Italy
[2] Univ Perugia, Dept Chem Biol & Biotechnol, Perugia, Italy
[3] Res Fdn, GEBISA, Perugia, Italy
关键词
Urinary cystatin C; Neonates; Method validation; Immunoblot SDS-PAGE; Reading of densitometry; Qualitative and quantitative analysis; CYSTEINE-PROTEINASE-INHIBITOR; ENHANCED TURBIDIMETRIC IMMUNOASSAY; LOW-BIRTH-WEIGHT; SERUM CREATININE; NEPHRON NUMBER; RENAL-FUNCTION; ASSAY; EXPRESSION; BIOMARKER; MARKER;
D O I
10.1016/j.clinbiochem.2020.10.005
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: The quantitative determination of urinary Cystatin C (cyst-C) associated with the qualitative analysis of its polymorphisms is an excellent method for early identification of newborns predisposed to renal function impairment. PETIA, PENIA and EIA are the immunometric methods used for the quantitative determination of cyst-C in human biologic fluid but they have limitations and do not allow qualitative analysis. The present study is a validation of Immunoblot SDS-PAGE for the qualitative and quantitative analysis of urinary cyst-C. Methods: Urine was collected from neonates in the nursey at S. Maria della Misericordia Hospital. Urinary cyst-C was investigated by the immunoblot SDS-PAGE and by reading of optical density. Results: The qualitative analysis showed two different molecular forms: a reactivity at about 70 KDa in all samples and a reactivity at 13 KDa in a limited number of samples. This analysis allows the correlation of the polymorphisms of cyst-C with specific alterations of renal function in newborns. The quantitative analysis is specific, sensitive and accurate. In fact the coefficient of variation for assay precision was 10% and for assay accuracy was +/- 10%, the detection limit was 0.009 ng/ mu L and the calibration line has satisfactory linearity (range 0.02-0.3 ng/ mu L). The stability of urinary cyst-C was acceptable, even without the use of protease inhibitors, as long as the assay was performed on freshly recruited urine or immediately after thawing the samples, which had been stored for up to six months. Conclusion: Immunoblot SDS-PAGE analysis is a valid method of obtaining a qualitative and quantitative analysis of urinary cyst-C. This method presents unique information about a previously unknown 70 KDa cyst-C form. The assay may offer potential diagnostic information not available with immunometric method.
引用
收藏
页码:52 / 59
页数:8
相关论文
共 59 条
[21]   Measurement of urinary cystatin C by particle-enhanced nephelometric immunoassay: precision, interferences, stability and reference range [J].
Herget-Rosenthal, S ;
Feldkamp, T ;
Volbracht, L ;
Kribben, A .
ANNALS OF CLINICAL BIOCHEMISTRY, 2004, 41 :111-118
[22]   Increased urinary cystatin C reflects structural and functional renal tubular impairment independent of glomerular filtration rate [J].
Herget-Rosenthal, Stefan ;
van Wijk, Joanna A. E. ;
Broecker-Preuss, Martina ;
Boekenkamp, Arend .
CLINICAL BIOCHEMISTRY, 2007, 40 (13-14) :946-951
[23]   THE EFFECT OF INTRAUTERINE GROWTH-RETARDATION ON THE DEVELOPMENT OF RENAL NEPHRONS [J].
HINCHLIFFE, SA ;
LYNCH, MRJ ;
SARGENT, PH ;
HOWARD, CV ;
VANVELZEN, D .
BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1992, 99 (04) :296-301
[24]  
HOLLAND P, 1993, LANCET, V341, P827, DOI 10.1016/0140-6736(93)90601-C
[25]   Glomerular number and size in autopsy kidneys: The relationship to birth weight [J].
Hughson, M ;
Farris, AB ;
Douglas-Denton, R ;
Hoy, WE ;
Bertram, JF .
KIDNEY INTERNATIONAL, 2003, 63 (06) :2113-2122
[26]   Urinary cystatin C can improve the renal safety follow-up of tenofovir-treated patients [J].
Jaafar, Acil ;
Seronie-Vivien, Sophie ;
Malard, Laurence ;
Massip, Patrice ;
Chatelut, Etienne ;
Tack, Ivan .
AIDS, 2009, 23 (02) :257-259
[27]   Thermal and guanidine hydrochloride-induced denaturation of human cystatin C [J].
Jankowska, E ;
Wiczk, W ;
Grzonka, Z .
EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2004, 33 (05) :454-461
[28]   Urinary Biomarkers in the Clinical Prognosis and Early Detection of Acute Kidney Injury [J].
Koyner, Jay L. ;
Vaidya, Vishal S. ;
Bennett, Michael R. ;
Ma, Qing ;
Worcester, Elaine ;
Akhter, Shahab A. ;
Raman, Jai ;
Jeevanandam, Valluvan ;
O'Connor, Micheal F. ;
Devarajan, Prasad ;
Bonventre, Joseph V. ;
Murray, Patrick T. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2010, 5 (12) :2154-2165
[29]  
KYHSEANDERSEN J, 1994, CLIN CHEM, V40, P1921
[30]   Improved immunoturbidimetric assay for cystatin C [J].
Lewis, AV ;
James, TJ ;
McGuire, JBJ ;
Taylor, RP .
ANNALS OF CLINICAL BIOCHEMISTRY, 2001, 38 :111-114