The Irish dual-energy X-ray absorptiometry (DXA) Health Informatics Prediction (HIP) for Osteoporosis Project

被引:12
|
作者
Erjiang, E. [1 ]
Wang, Tingyan [1 ,2 ]
Yang, Lan [1 ,3 ]
Dempsey, Mary [3 ]
Brennan, Attracta [4 ]
Yu, Ming [1 ]
Chan, Wing P. [5 ]
Whelan, Bryan [6 ,7 ]
Silke, Carmel [6 ,7 ]
O'Sullivan, Miriam [6 ,7 ]
Rooney, Bridie [8 ]
McPartland, Aoife [7 ]
O'Malley, Grainne [6 ,8 ]
Carey, John J. [6 ,9 ]
机构
[1] Tsinghua Univ, Dept Ind Engn, Beijing, Peoples R China
[2] Univ Oxford, Nuffield Dept Med, Oxford, England
[3] Natl Univ Ireland Galway, Sch Engn, Galway, Ireland
[4] Natl Univ Ireland Galway, Sch Comp Sci, Galway, Ireland
[5] Taipei Med Univ, Wan Fang Hosp, Dept Radiol, Taipei, Taiwan
[6] Natl Univ Ireland Galway, Sch Med, Galway, Ireland
[7] Our Ladys Univ Hosp, Dept Rheumatol, Manorhamilton, Ireland
[8] Sligo Univ Hosp, Dept Geriatr Med, Sligo, Ireland
[9] Galway Univ Hosp, Dept Rheumatol, Galway, Ireland
来源
BMJ OPEN | 2020年 / 10卷 / 12期
关键词
rheumatology; health informatics; risk management; bone diseases; POSTMENOPAUSAL WOMEN; CARDIOVASCULAR-DISEASE; ASSESSMENT TOOL; INCREASED RISK; BONE-DENSITY; FRACTURE; MANAGEMENT; MEN; BMD; POPULATION;
D O I
10.1136/bmjopen-2020-040488
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose The purpose of the Irish dual-energy X-ray absorptiometry (DXA) Health Informatics Prediction (HIP) for Osteoporosis Project is to create a large retrospective cohort of adults in Ireland to examine the validity of DXA diagnostic classification, risk assessment tools and management strategies for osteoporosis and osteoporotic fractures for our population. Participants The cohort includes 36 590 men and women aged 4-104 years who had a DXA scan between January 2000 and November 2018 at one of 3 centres in the West of Ireland. Findings to date 36 590 patients had at least 1 DXA scan, 6868 (18.77%) had 2 scans and 3823 (10.45%) had 3 or more scans. There are 364 unique medical disorders, 186 unique medications and 46 DXA variables identified and available for analysis. The cohort includes 10 349 (28.3%) individuals who underwent a screening DXA scan without a clear fracture risk factor (other than age), and 9947 (27.2%) with prevalent fractures at 1 of 44 skeletal sites. Future plans The Irish DXA HIP Project plans to assess current diagnostic classification and risk prediction algorithms for osteoporosis and fractures, identify the risk predictors for osteoporosis and develop novel, accurate and personalised risk prediction tools, by using the large multicentre longitudinal follow-up cohort. Furthermore, the dataset may be used to assess, and possibly support, multimorbidity management due to the large number of variables collected in this project.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Evaluating the prevalence of Osteoporosis through dual-energy X-ray absorptiometry in women
    Elnour, Hanan
    Elzaki, Amin
    Elhaj, Mona
    Kajoak, Samih
    Abdelwahid, Bahaaedin
    Alosaimi, Teaf
    Ibrahim, Ahmed A. M.
    BIOSCIENCE RESEARCH, 2022, 19 (01): : 431 - 436
  • [42] Osteoporosis in hemiplegic stroke patients as studied with dual-energy X-ray absorptiometry
    Liu, MG
    Tsuji, T
    Higuchi, Y
    Domen, K
    Tsujiuchi, K
    Chino, N
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (10): : 1219 - 1226
  • [43] MEASUREMENT OF THE CALCANEUS BY ULTRASOUND AND DUAL-ENERGY X-RAY ABSORPTIOMETRY IN POSTMENOPAUSAL OSTEOPOROSIS
    NAYLOR, KE
    LANGTON, CM
    SMITH, TWD
    EASTELL, R
    JOURNAL OF BONE AND MINERAL RESEARCH, 1993, 8 : S353 - S353
  • [44] Dual energy x-ray absorptiometry (DXA) and total hip prostheses: Methodological problem
    d'Arnaud, G
    Kingma, R
    Heyligers, IC
    Roos, JC
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1139 - 1139
  • [45] Dual-energy X-ray absorptiometry body composition in patients with secondary osteoporosis
    Messina, Carmelo
    Monaco, Cristian Giuseppe
    Ulivieri, Fabio Massimo
    Sardanelli, Francesco
    Sconfienza, Luca Maria
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (08) : 1493 - 1498
  • [46] Lower Lean Mass Measured by Dual-Energy X-ray Absorptiometry (DXA) is Not Associated with Increased Risk of Hip Fracture in Women: The Framingham Osteoporosis Study
    McLean, Robert R.
    Kiel, Douglas P.
    Berry, Sarah D.
    Broe, Kerry E.
    Zhang, Xiaochun
    Cupples, L. Adrienne
    Hannan, Marian T.
    CALCIFIED TISSUE INTERNATIONAL, 2018, 103 (01) : 16 - 23
  • [47] 3D MODELING OF HIP DUAL-ENERGY X-RAY ABSORPTIOMETRY (DXA) IN POSTMENOPAUSAL WOMEN TREATED WITH ROMOSOZUMAB
    Adami, G.
    Viapiana, O.
    Gatti, D.
    Fassio, A.
    Benini, C.
    Rossini, M.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2024, 36 : S272 - S274
  • [48] Lower Lean Mass Measured by Dual-Energy X-ray Absorptiometry (DXA) is Not Associated with Increased Risk of Hip Fracture in Women: The Framingham Osteoporosis Study
    Robert R. McLean
    Douglas P. Kiel
    Sarah D. Berry
    Kerry E. Broe
    Xiaochun Zhang
    L. Adrienne Cupples
    Marian T. Hannan
    Calcified Tissue International, 2018, 103 : 16 - 23
  • [49] Hip axis length measurement using dual-energy X-ray absorptiometry
    Roux, C
    Kolta, S
    Fechtenbaum, J
    Dougados, M
    REVUE DU RHUMATISME, 1997, 64 (04): : 243 - 248
  • [50] The usefulness of dual energy X-ray and laser absorptiometry of the calcaneus versus dual energy X-ray absorptiometry of hip and spine in diagnosing manifest osteoporosis
    de Klerk, Gijs
    van der Velde, D.
    van der Palen, J.
    van Bergeijk, L.
    Hegeman, J. H.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (02) : 251 - 257