Measurement of axial dispersion coefficient in a packed bed using X-ray

被引:3
|
作者
Basavaraj, MG [1 ]
Gupta, GS [1 ]
机构
[1] Indian Inst Sci, Dept Met, Bangalore 560012, Karnataka, India
关键词
dispersion; porous media; x-ray absorption; imaging; concentration;
D O I
10.1081/AMP-120016091
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Dispersion of the liquid in a porous media is of great importance in many areas of engineering and has been studied by several researchers so far. A new experimental method has been developed to measure the dispersion coefficient. X-ray absorption technique provides a better understanding of dispersion that characterizes the mixing phenomenon in the packed beds. This is because the method is non-invasive and also it gives tracer concentration data at every point within the bed. The axial dispersion in a cylindrical bed of non-porous and non-wetting spherical particles has been measured for the flow of water. Aqueous barium chloride solution has been used a as tracer. X-ray images, recorded on a videocassette, have been analyzed using an image processing software to extract the local interstitial velocity and concentration data in the bed. Local dispersion coefficient has been determined with the help of aforementioned data. By using these data, the overall dispersion coefficient in a packed bed can also be estimated.
引用
收藏
页码:683 / 692
页数:10
相关论文
共 50 条
  • [1] AXIAL DISPERSION IN A PACKED BED
    GOTTSCHLICH, CF
    AICHE JOURNAL, 1963, 9 (01) : 88 - 92
  • [2] ON MEASUREMENT OF X-RAY DISPERSION CORRECTIONS USING X-RAY INTERFEROMETERS
    CREAGH, DC
    AUSTRALIAN JOURNAL OF PHYSICS, 1970, 23 (01): : 99 - &
  • [3] SIMULTANEOUS AXIAL DISPERSION AND ADSORPTION IN A PACKED BED
    CHAO, R
    HOELSCHE.HE
    AICHE JOURNAL, 1966, 12 (02) : 271 - &
  • [4] Mass transfer coefficient measurement during brine flush in a CO2-filled packed bed by X-ray CT scanning
    Jiang, Lanlan
    Wu, Bohao
    Song, Yongchen
    Yang, Mingjun
    Wang, Dayong
    Liu, Yu
    Xue, Ziqiu
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 115 : 615 - 624
  • [5] Measurement and correlation of packed-bed axial dispersion coefficients in supercritical carbon dioxide
    Catchpole, OJ
    Bernig, R
    King, MB
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1996, 35 (03) : 824 - 828
  • [6] Measurement of the x-ray absorption coefficient of xenon
    White, TN
    PHYSICAL REVIEW, 1934, 46 (10): : 0865 - 0867
  • [7] AXIAL DISPERSION WITH CHEMICAL REACTION IN PACKED BED REACTORS
    CORRIGAN, TE
    BAUER, JL
    DEAN, MJ
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1970, 48 (01): : 139 - &
  • [8] Estimation of porosity and void fraction profiles in a packed bed of spheres using X-ray radiography
    Ito, Daisuke
    Ito, Kei
    Saito, Yasushi
    Aoyagi, Mitsuhiro
    Matsuba, Kenichi
    Kamiyama, Kenji
    NUCLEAR ENGINEERING AND DESIGN, 2018, 334 : 90 - 95
  • [9] Direct measurement of x-ray mass scattering coefficient
    Mertz, P
    PHYSICAL REVIEW, 1926, 28 (05): : 0891 - 0897
  • [10] AXIAL-DISPERSION IN PACKED-BED EXTRACTION COLUMNS
    SINGH, PC
    INDIAN JOURNAL OF TECHNOLOGY, 1986, 24 (02): : 101 - 102