Phase imaging with multiple phase-cycled balanced steady-state free precession at 9.4T

被引:0
作者
Kim, Jae-Woong [1 ]
Kim, Seong-Gi [2 ,3 ]
Park, Sung-Hong [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Bio & Brain Engn, Daejeon, South Korea
[2] Inst Basic Sci, Ctr Neurosci Imaging Res, Suwon, South Korea
[3] Sungkyunkwan Univ, Dept Biomed Engn, Suwon, South Korea
基金
新加坡国家研究基金会;
关键词
balanced steady-state free precession; functional MRI; gradient echo; high field; neuronal fiber; phase cycling; phase imaging; susceptibility; HIGH-FIELD MRI; HUMAN BRAIN; SUSCEPTIBILITY CONTRAST; BOLD SIGNALS; IRON CONTENT; SSFP FMRI; ECHO; RAT; SUPPRESSION; MICROSCOPY;
D O I
10.1002/nbm.3699
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
While phase imaging with a gradient echo (GRE) sequence is popular, phase imaging with balanced steady-state free precession (bSSFP) has been underexplored. The purpose of this study was to investigate anatomical and functional phase imaging with multiple phase-cycled bSSFP, in expectation of increasing spatial coverage of steep phase-change regions of bSSFP. Eight different dynamic 2D pass-band bSSFP studies at four phase-cycling (PC) angles and two T-E/T-R values were performed on rat brains at 9.4T with electrical forepaw stimulation, in comparison with dynamic 2D GRE. Anatomical and functional phase images were obtained by averaging the dynamic phase images and mapping correlation between the dynamic images and the stimulation paradigm, and were compared with their corresponding magnitude images. Phase imaging with 3D pass-band and 3D transition-band bSSFP was also performed for comparison with 3D GRE phase imaging. Two strategies of combining the multiple phase-cycled bSSFP phase images were also proposed. Contrast between white matter and gray matter in bSSFP phase images significantly varied with PC angle and became twice as high as that of GRE phase images at a specific PC angle. With the same total scan time, the combined bSSFP phase images provided stronger phase contrast and visualized neuronal fiber-like structures more clearly than the GRE phase images. The combined phase images of both 3D pass-band and 3D transition-band bSSFP showed phase contrasts stronger than those of the GRE phase images in overall brain regions, even at a longer T-E of 20ms. In contrast, phase functional MRI (fMRI) signals were weak overall and mostly located in draining veins for both bSSFP and GRE. Multiple phase-cycled bSSFP phase imaging is a promising anatomical imaging technique, while its usage as fMRI does not seem desirable with the current approach.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Single and double acquisition strategies for compensation of artifacts from eddy current and transient oscillation in balanced steady-state free precession
    Lee, Hyun-Soo
    Choi, Seung Hong
    Park, Sung-Hong
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (01) : 254 - 263
  • [42] Merging images with different central frequencies reduces banding artifacts in balanced steady-state free precession magnetic resonance cisternography
    Matsumoto, Koji
    Yokota, Hajime
    Mukai, Hiroki
    Masuda, Yoshitada
    Uno, Takashi
    Miyati, Tosiaki
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 234 - 243
  • [43] Feasibility of fetal cardiac function and anatomy assessment by real-time spiral balanced steady-state free precession magnetic resonance imaging at 0.55T
    Tian, Ye
    Detterich, Jon
    Pruetz, Jay D.
    Yagiz, Ecrin
    Wood, John C.
    Nayak, Krishna S.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2025, 27 (01)
  • [44] T2-prepared balanced steady-state free precession (bSSFP) for quantifying whole-blood oxygen saturation at 1.5T
    Rodriguez-Soto, Ana E.
    Abdulmalik, Osheiza
    Langham, Michael C.
    Schwartz, Nadav
    Lee, Hyunyeol
    Wehrli, Felix W.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 1893 - 1900
  • [45] Quantitative in vivo diffusion imaging of cartilage using double echo steady-state free precession
    Bieri, Oliver
    Ganter, Carl
    Scheffler, Klaus
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) : 720 - 729
  • [46] Utility of Balanced Steady-State Free Precession MR Venography in the Diagnosis of Lower Extremity Deep Venous Thrombosis
    Lindquist, Chris M.
    Karlicki, Fern
    Lawrence, Patrick
    Strzelczyk, Jacek
    Pawlyshyn, Neal
    Kirkpatrick, Iain D. C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05) : 1357 - 1364
  • [47] Principles and applications of the balanced steady-state free precession sequence in small animal low-field MRI
    Mario Ricciardi
    Veterinary Research Communications, 2018, 42 : 65 - 86
  • [48] Principles and applications of the balanced steady-state free precession sequence in small animal low-field MRI
    Ricciardi, Mario
    VETERINARY RESEARCH COMMUNICATIONS, 2018, 42 (01) : 65 - 86
  • [50] Balanced steady-state free precession thoracic imaging with half-radial dual-echo readout on smoothly interleaved archimedean spirals
    Bauman, Grzegorz
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (01) : 237 - 246