A comparison of patient-reported outcome measures (PROMs) between short and conventional stem hip replacements: a systematic review and meta-analysis

被引:11
|
作者
Babu, Satish [1 ]
Singh, Prashant [2 ]
Wiik, Anatole [1 ]
Shastri, Oliver [3 ]
Malik, Khalid [4 ]
Bailey, James [3 ]
Ghosh, Koushik [3 ]
Cobb, Justin [1 ]
机构
[1] Imperial Coll, London, England
[2] Barnet Hosp, Barnet, England
[3] Frimley Pk Hosp, Portsmouth Rd, Frimley GU16 7UJ, Surrey, England
[4] Conquest Hosp, Hastings, England
关键词
Patient satisfaction; PROM; short stem hip replacement; PERIPROSTHETIC BONE LOSS; CEMENTLESS FEMORAL STEM; UNCEMENTED STEMS; STRAIGHT STEM; ULTRA-SHORT; HARRIS HIP; ARTHROPLASTY; LENGTH; FIXATION; COMPONENT;
D O I
10.1177/1120700019888210
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Short stem hip replacements may allow preservation of proximal bone stock and minimise soft tissue disruption, easing future revision surgery. However patient satisfaction with these implants must be determined before widespread use. We aimed to compare patient reported outcome measures (PROMs) between short and conventional stem hip replacements. Methods: A systematic review was conducted according to PRISMA guidelines for studies comparing short and conventional stem hip replacements with validated PROMs. Meta-analyses were performed for studies reporting Harris Hip and WOMAC scores. Study bias was assessed with the Cochrane Risk of Bias tool and Newcastle-Ottawa Scale. Results: 24 studies, incorporating 2593 total hip replacements were included for qualitative analysis. 17 studies were included in the meta-analyses. Of the 7 excluded, 1 study reported the Japanese Orthopaedic Association score and 2 others reported the Oxford Hip score. All three showed no difference between the stems. A meta-analysis of 17 studies reporting Harris hip scores showed no statistically significant difference between short and conventional stems (standard mean difference (SMD) -0.06, 95% CI -0.20-0.07, p = 0.35). 6 studies reported WOMAC scores with higher scores indicating worse outcome. No difference was seen between the two groups (SMD 0.21, 95%CI, -0.01-0.42, p = 0.06). 4 studies reported higher WOMAC scores as better. Once again, a meta-analysis showed no statistically significant difference between the stems (SMD 0.28, 95% CI -0.07-0.63, p = 0.12). Conclusions: Our systematic review showed no difference in PROMs between short and conventional stem total hip replacements. This is in keeping with previous evidence but is a more comprehensive analysis. Short stems may have an important role in younger individuals as they allow preservation of proximal femoral bone, minimal access surgery and are amenable to abnormal anatomy. The current literature is hindered by non-uniform methodologies and outcome assessments across studies. Further, standardised, high quality evidence is required before widespread changes in practice.
引用
收藏
页码:513 / 522
页数:10
相关论文
共 50 条
  • [1] Patient-reported outcome measures (PROMs) of implant-supported reconstructions using digital workflows: A systematic review and meta-analysis
    Bishti, Shaza
    Tuna, Taskin
    Rittich, Anne
    Wolfart, Stefan
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 : 318 - 335
  • [2] A comparison of short-stem prostheses and conventional stem prostheses in primary total hip arthroplasty: a systematic review and meta-analysis of randomized controlled trials
    Zhang, Zhen
    Xing, Qiqi
    Li, Jingyi
    Jiang, Zichao
    Pan, Yixiao
    Hu, Yihe
    Wang, Long
    ANNALS OF TRANSLATIONAL MEDICINE, 2021, 9 (03)
  • [3] ASES and UCLA Are Responsive Patient-Reported Outcome Measures After Rotator Cuff Repair: A Systematic Review and Meta-analysis
    Abed, Varag
    Kapp, Sabryn
    Nichols, Michael
    Brunty, Nathan
    Conley, Caitlin E. W.
    Jacobs, Cale A.
    Robinson, Lauren E.
    Stone, Austin V.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2024, : 3173 - 3178
  • [4] ASES and UCLA Are Responsive Patient-Reported Outcome Measures After Rotator Cuff Repair: A Systematic Review and Meta-analysis
    Abed, Varag
    Kapp, Sabryn
    Nichols, Michael
    Brunty, Nathan
    Conley, Caitlin E. W.
    Jacobs, Cale A.
    Robinson, Lauren E.
    Stone, Austin V.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2024, 52 (12) : 3173 - 3178
  • [5] The effectiveness of robotic hip and knee arthroplasty on patient-reported outcomes: A systematic review and meta-analysis
    Karunaratne, Sascha
    Duan, Michael
    Pappas, Evangelos
    Fritsch, Brett
    Boyle, Richard
    Gupta, Sanjeev
    Stalley, Paul
    Horsley, Mark
    Steffens, Daniel
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (06) : 1283 - 1295
  • [6] The effectiveness of robotic hip and knee arthroplasty on patient-reported outcomes: A systematic review and meta-analysis
    Sascha Karunaratne
    Michael Duan
    Evangelos Pappas
    Brett Fritsch
    Richard Boyle
    Sanjeev Gupta
    Paul Stalley
    Mark Horsley
    Daniel Steffens
    International Orthopaedics, 2019, 43 : 1283 - 1295
  • [7] Patient-reported outcome measures for patellofemoral disorders: a systematic review
    Rosa, Sergio Barroso
    Grant, Andrea
    McEwen, Peter
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (07) : 3919 - 3927
  • [8] Two-stage revisions of infected hip replacements: Subspecialisation and patient-reported outcome measures
    Matar, Hosam E.
    Stritch, Paula
    Emms, Nicholas
    JOURNAL OF ORTHOPAEDICS, 2019, 16 (02) : 179 - 181
  • [9] Influence of Patient-Reported Outcome Measures by Surgical Versus Conservative Management in Adult Ankle Fractures: A Systematic Review and Meta-Analysis
    Peng, Hui
    Guo, Xiao-Bo
    Zhao, Jin-Min
    MEDICINA-LITHUANIA, 2023, 59 (06):
  • [10] Patient-reported outcome measures for patellofemoral disorders: a systematic review
    Sergio Barroso Rosa
    Andrea Grant
    Peter McEwen
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 3919 - 3927