A comparison of conventional versus locking plates in intraarticular calcaneus fractures: A biomechanical study in human cadavers

被引:51
|
作者
Stoffel, Karl
Booth, Grant
Rohrl, Stephan M.
Kuster, Markus
机构
[1] Univ Western Australia, Fremantle Orthopaed Unit, Fremantle, WA 6160, Australia
[2] Kantonsspital St Gallen, Dept Orthopaed, CH-9007 St Gallen, Switzerland
关键词
calcaneal fracture; plate fixation; locked screws; conventional screws; biomechanical testing;
D O I
10.1016/j.clinbiomech.2006.07.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Internal fixation of displaced intraarticular calcaneal fractures in patients older than 50 years remains controversial. This is, in many cases, due to fear of loss of fixation and the risk of implant failure in osteoporotic bone. It is the objective of this study to compare the fixation strength obtained using calcaneal plates with and without locking screws, in the fixation of osteoporotic cadaveric intraarticular calcaneal fractures. Methods. In seven pairs of fresh frozen lower limbs cadavers, intraarticular calcaneal fractures were created with a dynamic single impact loading device and stabilized using either the low profile locking plate, or the conventional calcaneus plate. Radiographs were obtained to assess reduction. The specimens were then subjected to cyclic loading followed by loading to failure, using matched pairs of cadaveric lower limbs. The Wilcoxon signed rank test was used to test for differences in the results. Findings. The locking plate showed a significant lower irreversible deformation during cyclic loading and a significant higher load to failure. The difference between the ultimate displacement, and work to failure was not significant. A low bone mineral content in the area of the posterior facet correlated only in the conventional plate group with increased irreversible deformation. Interpretation. This study supports the mechanical viability of using locking calcancal plates for the fixation of intraarticular calcaneal fractures in elderly patients. Crown Copyright (c) 2006 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [31] Biomechanical evaluation of reconstruction plates with locking, nonlocking, and hybrid screws configurations in calcaneal fracture: a finite element model study
    Ching-Hsuan Chen
    Chinghua Hung
    Yu-Chun Hsu
    Chen-Sheng Chen
    Chao-Ching Chiang
    Medical & Biological Engineering & Computing, 2017, 55 : 1799 - 1807
  • [32] A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
    Rausch, Sascha
    Klos, Kajetan
    Wolf, Uwe
    Gras, Marc
    Simons, Paul
    Brodt, Steffen
    Windolf, Markus
    Gueorguiev, Boyko
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (08) : 1705 - 1710
  • [33] A biomechanical comparison of fixed angle locking compression plate osteosynthesis and cement augmented screw osteosynthesis in the management of intra articular calcaneal fractures
    Sascha Rausch
    Kajetan Klos
    Uwe Wolf
    Marc Gras
    Paul Simons
    Steffen Brodt
    Markus Windolf
    Boyko Gueorguiev
    International Orthopaedics, 2014, 38 : 1705 - 1710
  • [34] Minimally Invasive Intramedullary Screw Versus Plate Fixation for Proximal Phalanx Fractures: A Biomechanical Study
    Miles, Megan R.
    Krul, Kevin P.
    Abbasi, Pooyan
    Thakkar, Madhuli Y.
    Giladi, Aviram M.
    Means, Kenneth R., Jr.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2021, 46 (06): : 518.e1 - 518.e8
  • [35] The infraacetabular screw versus the antegrade posterior column screw in acetabulum fractures with posterior column involvement: a biomechanical comparison
    Hinz, Nico
    Baumeister, Dirk
    Dehoust, Julius
    Muench, Matthias
    Frosch, Karl-Heinz
    Augat, Peter
    Hartel, Maximilian J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (06) : 2573 - 2582
  • [36] Comparison of screw versus locking plate fixation via sinus tarsi approach for displaced intra-articular calcaneal fractures
    Sato, Kohei
    Yorimitsu, Masanori
    Uehara, Takenori
    Fukuoka, Shiro
    Hata, Toshiaki
    Saiga, Kenta
    Noda, Tomoyuki
    Ozaki, Toshifumi
    FOOT AND ANKLE SURGERY, 2023, 29 (01) : 97 - 102
  • [37] Biomechanical Comparison of Different Stabilization Constructs for Unstable Posterior Wall Fractures of Acetabulum. A Cadaveric Study
    Zhang, Yuntong
    Tang, Yang
    Wang, Panfeng
    Zhao, Xue
    Xu, Shuogui
    Zhang, Chuncai
    PLOS ONE, 2013, 8 (12):
  • [38] Comparison of Long Segmental Dorsal Stabilization with Complete Versus Restricted Pedicle Screw Cement Augmentation in Unstable Osteoporotic Midthoracic Vertebral Body Fractures: A Biomechanical Study
    Spiegl, Ulrich J.
    Weidling, Martin
    Schleifenbaum, Stefan
    Reinhardt, Martin
    Heyde, Christoph-E.
    WORLD NEUROSURGERY, 2020, 143 : E541 - E549
  • [39] Minimally Invasive Reduction of Intraarticular Calcaneal Fractures With Percutaneous Fixation Using Cannulated Screws Versus Kirschner Wires: A Retrospective Comparative Study
    Shams, Ahmed
    Gamal, Osama
    Mesregah, Mohamed Kamal
    FOOT & ANKLE SPECIALIST, 2023, 16 (01) : 28 - 35
  • [40] Biomechanical Comparison of Parallel Versus 90-90 Plating of Bicolumn Distal Humerus Fractures With Intra-Articular Comminution
    Got, Christopher
    Shuck, John
    Biercevicz, Alison
    Paller, Dave
    Mulcahey, Mary
    Zimmermann, Matthew
    Blaine, Theodore
    Green, Andrew
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (12): : 2512 - 2518