A comparison of conventional versus locking plates in intraarticular calcaneus fractures: A biomechanical study in human cadavers

被引:51
|
作者
Stoffel, Karl
Booth, Grant
Rohrl, Stephan M.
Kuster, Markus
机构
[1] Univ Western Australia, Fremantle Orthopaed Unit, Fremantle, WA 6160, Australia
[2] Kantonsspital St Gallen, Dept Orthopaed, CH-9007 St Gallen, Switzerland
关键词
calcaneal fracture; plate fixation; locked screws; conventional screws; biomechanical testing;
D O I
10.1016/j.clinbiomech.2006.07.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Internal fixation of displaced intraarticular calcaneal fractures in patients older than 50 years remains controversial. This is, in many cases, due to fear of loss of fixation and the risk of implant failure in osteoporotic bone. It is the objective of this study to compare the fixation strength obtained using calcaneal plates with and without locking screws, in the fixation of osteoporotic cadaveric intraarticular calcaneal fractures. Methods. In seven pairs of fresh frozen lower limbs cadavers, intraarticular calcaneal fractures were created with a dynamic single impact loading device and stabilized using either the low profile locking plate, or the conventional calcaneus plate. Radiographs were obtained to assess reduction. The specimens were then subjected to cyclic loading followed by loading to failure, using matched pairs of cadaveric lower limbs. The Wilcoxon signed rank test was used to test for differences in the results. Findings. The locking plate showed a significant lower irreversible deformation during cyclic loading and a significant higher load to failure. The difference between the ultimate displacement, and work to failure was not significant. A low bone mineral content in the area of the posterior facet correlated only in the conventional plate group with increased irreversible deformation. Interpretation. This study supports the mechanical viability of using locking calcancal plates for the fixation of intraarticular calcaneal fractures in elderly patients. Crown Copyright (c) 2006 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 50 条
  • [1] Biomechanical comparison of conventional and optimised locking plates for the fixation of intraarticular calcaneal fractures: a finite element analysis
    Ouyang, Hanbin
    Deng, Yuping
    Xie, Pusheng
    Yang, Yang
    Jiang, Bingyun
    Zeng, Canjun
    Huang, Wenhua
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (12) : 1339 - 1349
  • [2] A biomechanical comparison of conventional versus an anatomic plate and compression bolts for fixation of intra-articular calcaneal fractures
    Haili Wang
    Zhaoxu Yang
    Zhanpo Wu
    Wei Chen
    Qi Zhang
    Ming Li
    Zhiyong Li
    Yingze Zhang
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2012, 32 : 571 - 575
  • [3] A Biomechanical Comparison of Conventional versus an Anatomic Plate and Compression Bolts for Fixation of Intra-articular Calcaneal Fractures
    王海立
    杨朝旭
    吴战坡
    陈伟
    张奇
    李明
    李智勇
    张英泽
    Current Medical Science, 2012, 32 (04) : 571 - 575
  • [4] A biomechanical comparison of conventional versus an anatomic plate and compression bolts for fixation of intra-articular calcaneal fractures
    Wang, Haili
    Yang, Zhaoxu
    Wu, Zhanpo
    Chen, Wei
    Zhang, Qi
    Li, Ming
    Li, Zhiyong
    Zhang, Yingze
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2012, 32 (04) : 571 - 575
  • [5] Straight and helical plating with locking plates for proximal humeral shaft fractures - a biomechanical comparison under physiological load conditions
    Halbauer, Christian
    Capanni, Felix
    Paech, Andreas
    Knop, Christian
    Merkle, Tobias
    Da Silva, Tomas
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2024,
  • [6] Biomechanical Comparison of Fixed- versus Variable-Angle Locking Screws for Distal Humerus Comminuted Fractures
    Nourbakhsh, Ali
    Hirschfeld, Adam G.
    Dhulipala, Sravan
    Hutton, William
    Ganey, Timothy
    Lozada, Luis
    Schlatterer, Daniel
    Lourie, Gary Mark
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (03) : 302 - 308
  • [7] Biomechanical testing of osteosynthetic locking plates for proximal humeral shaft fractures - a systematic literature review
    Halbauer, Christian
    Capanni, Felix
    Bertusch, Isabel
    Paech, Andreas
    Merkle, Tobias
    Da Silva, Tomas
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2023, 68 (06): : 553 - 561
  • [8] Biomechanical Comparison of Two Locking Plate Constructs for the Stabilization of Feline Tibial Fractures
    Hottmann, Natasha M.
    Johnson, Matthew D.
    Banks, Scott A.
    Tuyn, David
    Lewis, Daniel D.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 33 (02) : 89 - 95
  • [9] Far cortical locking versus standard locking screw fixation in simulated femoral fractures: A biomechanical meta-analysis
    Bullock, Robert S.
    Coury, John G.
    Liakos, Brendan
    Huish, Eric G.
    JOURNAL OF ORTHOPAEDICS, 2025, 61 : 43 - 46
  • [10] Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures
    Ming Ni
    Duo Wai-Chi Wong
    Jiong Mei
    Wenxin Niu
    Ming Zhang
    Science China(Life Sciences), 2016, 59 (09) : 958 - 964