Oscillometric Waveform Difference between Cuff Inflation and Deflation during Blood Pressure Measurement

被引:0
|
作者
Liu, Chengyu [1 ]
Zheng, Dingchang [1 ]
Griffiths, Clive [1 ]
Murray, Alan [1 ]
机构
[1] Newcastle Univ, Inst Cellular Med, Newcastle Upon Tyne NE1 4LP, Tyne & Wear, England
来源
2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41 | 2014年 / 41卷
关键词
HYPERTENSION;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The majority of automatic blood pressure (BP) measurement devices use the oscillometric method made during cuff inflation or deflation. However, there is currently little information available on the comparison of oscillometric waveform shape between cuff inflation and deflation. This study aimed to provide this information. Oscillometric cuff pressure waveforms were recorded digitally from 10 normotensive subjects during standard BP measurement at slow linear inflation and deflation rates of 2-3 mmHg/s. Three repeat sessions were performed for each subject. Four features were quantified for each oscillometric waveform: the maximum oscillometric pulse peak amplitude (Amax) and three cuff pressure widths corresponding to 70%, 50% and 30% of Amax (denoted as W70, W50 and W30 respectively). For all subjects, these oscillometric waveform features were then compared between cuff inflation and deflation. Analysis of variance showed that there was no significant difference between the three repeat measurements for all four waveform features (all P>0.4). Mean Amax from cuff inflation was 0.7 mmHg higher (mean +/- SD: 3.7 +/- 0.9 vs. 3.0 +/- 0.8 mmHg, P<0.001) than that from cuff deflation. For the cuff pressure widths at the three thresholds, W70 was not significantly different between cuff inflation and deflation, but W50 and W30 were both significantly narrower for cuff inflation by 12 mmHg (45 +/- 9 vs. 57 +/- 11 mmHg) and 22 mmHg narrower (67 +/- 10 vs. 89 +/- 12 mmHg) respectively; both P<0.001. The oscillometric waveform differences during BP measurement suggest that arteries may behave differently during cuff inflation and deflation.
引用
收藏
页码:849 / 852
页数:4
相关论文
共 50 条
  • [41] Correct placement of blood pressure cuff during blood pressure measurement
    Garcia, Mary Grace Uranza
    Ang, Emily
    Ahmad, Noor Melati
    Lim, Chi Ching
    INTERNATIONAL JOURNAL OF EVIDENCE-BASED HEALTHCARE, 2012, 10 (03): : 191 - 196
  • [42] CUFF-LESS BLOOD PRESSURE MEASUREMENT USING THE PULSE TRANSIT TIME - A COMPARISON TO CUFF-BASED OSCILLOMETRIC 24 HOUR BLOOD PRESSURE MEASUREMENT IN CHILDREN
    Hulpke-Wette, M.
    Goehler, A.
    Hofmann, E.
    Kuechler, G.
    JOURNAL OF HYPERTENSION, 2018, 36 : E73 - E73
  • [43] THE EFFECT OF CUFF PRESSURE DEFLATION RATE ON ACCURACY IN INDIRECT MEASUREMENT OF BLOOD-PRESSURE WITH THE AUSCULTATORY METHOD
    YONG, PG
    GEDDES, LA
    JOURNAL OF CLINICAL MONITORING, 1987, 3 (03): : 155 - 159
  • [44] OSCILLOMETRIC MEASUREMENT OF ARTERIAL BLOOD PRESSURE
    BENSON, H
    HERD, JA
    CIRCULATION, 1969, 40 (4S3) : II43 - &
  • [45] Noninvasive Blood Pressure Measurement in Maintenance Hemodialysis Patients: Comparison of Agreement between Oscillometric and Finger-Cuff Methods
    Alfano, Gaetano
    Fontana, Francesco
    Cappelli, Gianni
    NEPHRON, 2017, 136 (04) : 309 - 317
  • [46] Validation of a Blood Pressure Simulator that Regenerates Oscillometric Cuff Pressure Waveforms
    Zheng, Dingchang
    Liu, Chengyu
    Amoore, John
    Mieke, Stephan
    Murray, Alan
    2014 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), VOL 41, 2014, 41 : 841 - 844
  • [47] EVALUATION OF OSCILLOMETRIC BLOOD PRESSURE MEASUREMENT USING A FINGER CUFF IN ANESTHETIZED CHIMPANZEES (PAN TROGLODYTES)
    Cassady, Katherine R.
    Balko, Julie A.
    Bailey, Kate M.
    Posner, Lysa P.
    Robertson, James B.
    Minter, Larry J.
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 2023, 54 (01) : 16 - 22
  • [48] Cuff inflation during ambulatory blood pressure monitoring and heart rate
    Skov-Madsen, Mia
    Svensson, My
    Christensen, Jeppe Hagstrup
    INTEGRATED BLOOD PRESSURE CONTROL, 2008, 1 : 15 - 19
  • [49] Quantitative analysis of the effect of clothing on the oscillometric waveform envelope and oscillometric blood pressure measurements
    Kim, Jeonghoon
    Lee, Jongshill
    Lee, Jeyeon
    Park, Hoon-Ki
    Kim, In Young
    BIOMEDICAL ENGINEERING LETTERS, 2025, : 525 - 536
  • [50] Effect of Cuff Design on Auscultatory and Oscillometric Blood Pressure Measurements
    Ringrose, Jennifer S.
    McLean, Donna
    Ao, Peter
    Yousefi, Farahnaz
    Sankaralingam, Sowndramalingam
    Millay, Jack
    Padwal, Raj
    AMERICAN JOURNAL OF HYPERTENSION, 2016, 29 (09) : 1063 - 1069