Experimental realization of open magnetic shielding

被引:26
作者
Gu, C. [1 ]
Chen, S. [2 ]
Pang, T. [1 ]
Qu, T. -M. [3 ]
机构
[1] Tsinghua Univ, Teaching Ctr Expt Phys, Beijing 100084, Peoples R China
[2] Eastforce Superconducting Technol Co Ltd, Beijing 100085, Peoples R China
[3] Tsinghua Univ, Dept Mech Engn, Key Lab Adv Mat Proc Technol, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
LOW-FREQUENCY; WIRE;
D O I
10.1063/1.4983490
中图分类号
O59 [应用物理学];
学科分类号
摘要
The detection of extremely low magnetic fields has various applications in the area of fundamental research, medical diagnosis, and industry. Extracting the valuable signals from noises often requires magnetic shielding facilities. We demonstrated directly from Maxwell's equations that specifically designed superconductor coils can exactly shield the magnetic field to an extremely low value. We experimentally confirmed this effect in the frequency spectrum of 0.01-10 000Hz and improved the electromagnetic environment in a hospital, a leading hospital in magnetocardiograph study in China. Published by AIP Publishing.
引用
收藏
页数:4
相关论文
共 25 条
[1]  
Abbott B. P., 2016, PHYS REV LETT, V116, DOI DOI 10.1103/PHYSREVLETT.116.061102
[2]   A large-scale magnetic shield with 106 damping at millihertz frequencies [J].
Altarev, I. ;
Bales, M. ;
Beck, D. H. ;
Chupp, T. ;
Fierlinger, K. ;
Fierlinger, P. ;
Kuchler, F. ;
Lins, T. ;
Marino, M. G. ;
Niessen, B. ;
Petzoldt, G. ;
Schlaepfer, U. ;
Schnabel, A. ;
Singh, J. T. ;
Stoepler, R. ;
Stuiber, S. ;
Sturm, M. ;
Taubenheim, B. ;
Voigt, J. .
JOURNAL OF APPLIED PHYSICS, 2015, 117 (18)
[3]   Ultrasensitive magnetic field detection using a single artificial atom [J].
Bal, M. ;
Deng, C. ;
Orgiazzi, J. -L. ;
Ong, F. R. ;
Lupascu, A. .
NATURE COMMUNICATIONS, 2012, 3
[4]   Optical magnetometry [J].
Budker, Dmitry ;
Romalis, Michael .
NATURE PHYSICS, 2007, 3 (04) :227-234
[5]   Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer [J].
Dang, H. B. ;
Maloof, A. C. ;
Romalis, M. V. .
APPLIED PHYSICS LETTERS, 2010, 97 (15)
[6]   Scanning magnetic field microscope with a diamond single-spin sensor [J].
Degen, C. L. .
APPLIED PHYSICS LETTERS, 2008, 92 (24)
[7]   PET/MRI system design [J].
Delso, Gaspar ;
Ziegler, Sibylle .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 :86-92
[8]   Electromagnetic formation flight dynamics including reaction wheel gyroscopic stiffening effects [J].
Elias, Laila M. ;
Kwon, Daniel W. ;
Sedwick, Raymond J. ;
Miller, David W. .
JOURNAL OF GUIDANCE CONTROL AND DYNAMICS, 2007, 30 (02) :499-511
[9]   Magnetic shielding properties of high-Tc superconducting hollow cylinders: model combining experimental data for axial and transverse magnetic field configurations [J].
Fagnard, J-F ;
Dirickx, M. ;
Ausloos, M. ;
Lousberg, G. ;
Vanderheyden, B. ;
Vanderbemden, Ph .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2009, 22 (10)
[10]   Virgin magnetization of a magnetically shielded superconductor wire: Theory and experiment [J].
Genenko, YA ;
Yampolskii, SV ;
Pan, AV .
APPLIED PHYSICS LETTERS, 2004, 84 (19) :3921-3923