EMG-monitoring during functional electrical stimulation

被引:0
作者
Bijak, M
Girsch, W
Rafolt, D
Mayr, W
Lanmüller, H
机构
[1] Univ Vienna, Inst Biomed Tech & Phys, A-1090 Vienna, Austria
[2] Univ Vienna, Klin Abt Wiederherstellungs & Plast Chirurg, A-1090 Vienna, Austria
来源
BIOMEDIZINISCHE TECHNIK | 2000年 / 45卷 / 04期
关键词
FES; EMG; force; electrical stimulation; monitoring;
D O I
10.1515/bmte.2000.45.4.93
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
When using functional electrical stimulation (FES), correct adjustment of stimulation parameters, and monitoring of the stimulated muscle is mandatory if tissue damage is to be avoided. Although several FES systems are already in regular use, a method for direct muscle monitoring is still lacking. This paper investigates the suitability of the electromyogram (EMG) for such a purpose. In six sheep, the right latissimus dorsi muscle (LDM) and the associated thoracodorsal nerve were exposed. Stimulation was effected via electrodes placed on the nerve. Three electrodes were placed in the LDM for EMG recording, and the tendon was connected to a force transducer for isometric force measurement. Stimulation was applied for one second (burst), followed by a three-second pause. The stimulation current was increased in 0.2 mA steps, starting at 0 mA and ending at 4 mA. Throughout the investigation, the EMG signal was monitored with an oscilloscope. In addition, the EMG signal and the force transducer signal were recorded for subsequent analysis. An analysis of the data of all six sheep revealed an almost linear relationship between muscle force and m-wave amplitude (\r\ = 0.95, p < 0.001) M-wave monitoring during EMG recording with three intramuscular electrodes is a reliable method of monitoring FES-induced muscle activity, but the absolute force cannot be measured.
引用
收藏
页码:93 / 97
页数:13
相关论文
共 50 条
  • [31] Biopotentials as command and feedback signals in functional electrical stimulation systems
    Sinkjaer, T
    Haugland, M
    Inmann, A
    Hansen, M
    Nielsen, KD
    MEDICAL ENGINEERING & PHYSICS, 2003, 25 (01) : 29 - 40
  • [32] Continuous EMG recordings and intraoperative electrical stimulation for identification and protection of cervical nerve roots during foraminal tumor surgery
    Guo, LJ
    Quiñones-Hinojosa, A
    Yingling, CD
    Weinstein, PR
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2006, 19 (01): : 37 - 42
  • [33] Functional electrical stimulation enhancement of upper extremity functional recovery during stroke rehabilitation: A pilot study
    Alon, Gad
    Levitt, Alan F.
    McCarthy, Patricia A.
    NEUROREHABILITATION AND NEURAL REPAIR, 2007, 21 (03) : 207 - 215
  • [34] CONTINENCE FOLLOWING ELECTRICAL-STIMULATION AND EMG BIOFEEDBACK IN A TEENAGER WITH IMPERFORATE ANUS
    KIRSCH, SE
    SHANDLING, B
    WATSON, SL
    GILMOUR, RF
    PAPE, KE
    JOURNAL OF PEDIATRIC SURGERY, 1993, 28 (10) : 1408 - 1410
  • [35] Site of facilitation of diaphragm EMG to corticospinal stimulation during inspiration
    Davey, NJ
    Murphy, K
    Maskill, DW
    Guz, A
    Ellaway, PH
    RESPIRATION PHYSIOLOGY, 1996, 106 (02): : 127 - 135
  • [36] Distributed stimulation increases force elicited with functional electrical stimulation
    Buckmire, Alie J.
    Lockwood, Danielle R.
    Doane, Cynthia J.
    Fuglevand, Andrew J.
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (02)
  • [37] High resolution functional photoacoustic computed tomography of the mouse brain during electrical stimulation
    Avanaki, Mohammad R. N.
    Xia, Jun
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2013, 2013, 8581
  • [38] Ultrasound Echogenicity-based Assessment of Muscle Fatigue During Functional Electrical Stimulation
    Zhang, Qiang
    Iyer, Ashwin
    Lambeth, Krysten
    Kim, Kang
    Sharma, Nitin
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 5948 - 5952
  • [39] Mechanomyography for the Measurement of Muscle Fatigue Caused by Repeated Functional Electrical Stimulation
    Jo, Min
    Ahn, Soonjae
    Kim, Jongman
    Koo, Bummo
    Jeong, Youngjae
    Kim, Seongjung
    Kim, Youngho
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2018, 19 (09) : 1405 - 1410
  • [40] Functional electrical stimulation using voluntary eyeblink for foot drop correction
    Champaty, Biswajeet
    Pal, Kunal
    Dash, Aiswarya
    2013 ANNUAL INTERNATIONAL CONFERENCE ON EMERGING RESEARCH AREAS & 2013 INTERNATIONAL CONFERENCE ON MICROELECTRONICS, COMMUNICATIONS & RENEWABLE ENERGY (AICERA/ICMICR), 2013,