Online geometrical calibration of a mobile C-arm using external sensors

被引:5
作者
Mitschke, MM [1 ]
Navab, N [1 ]
Schütz, O [1 ]
机构
[1] Siemens AG Med Engn GT1, D-91052 Erlangen, Germany
来源
MEDICAL IMAGING 2000: IMAGE DISPLAY AND VISUALIZATION | 2000年 / 3976卷
关键词
3D tomographic reconstruction; X-ray C-arm systems; external tracking systems; recovery of projection geometry;
D O I
10.1117/12.383086
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
3D tomographic reconstruction of high contrast objects such as contrast agent enhanced brood vessels or banes from Xray images acquired by isocentric Carm systems recently gained interest. For tomographic reconstruction, a sequence of images is captured during the Garm rotation around the patient and the precise projection geometry has to be determined for each image. This is a difficult task, as Germs usually do not provide accurate information about their projection geometry. Standard methods propose the use of an X-ray calibration phantom and an offline calibration, when the motion of the C-arm is supposed to be reproducible between calibration and patient run. However, mobile C-arms usually do not have this desirable property. Therefore, an online recovery of projection geometry is necessary. Here, we study the use of external tracking systems, such as Polaris or Optotrak from Northern Digital, Inc., for online calibration. In order to use the external tracking system for recovery of X-ray projection geometry two unknown transformations have to be estimated. We describe our attempt to solve this calibration problem. These are the relations between X-ray imaging system and marker plate of the tracking system as well as world and sensor coordinate system. Experimental results on anatomical data are presented and visually compared with the results of estimating the projection geometry with an X-ray calibration phantom.
引用
收藏
页码:580 / 587
页数:8
相关论文
共 13 条
[1]   Three-dimensional computed tomographic reconstruction using a C-arm mounted XRII: Correction of image intensifier distortion [J].
Fahrig, R ;
Moreau, M ;
Holdsworth, DW .
MEDICAL PHYSICS, 1997, 24 (07) :1097-1106
[2]  
Faugeras O. D., 1986, Proceedings CVPR '86: IEEE Computer Society Conference on Computer Vision and Pattern Recognition (Cat. No.86CH2290-5), P15
[3]  
GANAPATHY S, 1998, P INT C ROB AUT, P130
[4]   The accuracy and reproducibility of a global method to correct for geometric image distortion in the x-ray imaging chain [J].
Gronenschild, E .
MEDICAL PHYSICS, 1997, 24 (12) :1875-1888
[5]  
KEMKERS R, 1998, COMPUTER ASSISTED RA
[6]  
KOPPE P, 1995, COMPUTER ASSISTED RA, P101
[7]  
MITSCHKE M, 1999, SIEMENS CORPORAT NOV
[8]   Dynamic geometrical calibration for 3-D cerebral angiography [J].
Navab, N ;
BaniHashemi, A ;
Mitschke, M ;
Holdsworth, DW ;
Fahrig, R ;
Fox, AJ ;
Graumann, R .
PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 :361-370
[9]  
NAVAB N, 1998, 1 INT C MED IM COMP, P119
[10]  
NAVAB N, 1909, 2 INT C MED IM COMP, P688