Theoretical determination of gamma spectrometry systems efficiency based on probability functions. Application to self-attenuation correction factors

被引:8
|
作者
Barrera, Manuel [1 ]
Suarez-Llorens, Alfonso [2 ]
Casas-Ruiz, Melquiades [3 ]
Alonso, Jose J. [3 ]
Vidal, Juan [3 ]
机构
[1] Univ Cadiz, Escuela Super Ingn, Avda,Univ Cadiz 10, Cadiz 11519, Spain
[2] Univ Cadiz, Fac Ciencias, Avda,Rep Saharaui S-N, Cadiz 11510, Spain
[3] Univ Cadiz, CEIMAR, Avda,Rep Saharaui S-N, Cadiz 11510, Spain
关键词
Gamma spectrometry; HPGe detectors; Theoretical efficiency calculations; FEP efficiency; Total efficiency; Self-attenuation corrections; MONTE-CARLO-SIMULATION; RAY SPECTROMETRY; ENVIRONMENTAL-SAMPLES; PEAK EFFICIENCY; DETECTORS; GEOMETRY;
D O I
10.1016/j.nima.2017.02.052
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A generic theoretical methodology for the calculation of the efficiency of gamma spectrometry systems is introduced in this work. The procedure is valid for any type of source and detector and can be applied to determine the full energy peak and the total efficiency of any source-detector system. The methodology is based on the idea of underlying probability of detection, which describes the physical model for the detection of the gamma radiation at the particular studied situation. This probability depends explicitly on the direction of the gamma radiation, allowing the use of this dependence the development of more realistic and complex models than the traditional models based on the point source integration. The probability function that has to be employed in practice must reproduce the relevant characteristics of the detection process occurring at the particular studied situation. Once the probability is defined, the efficiency calculations can be performed in general by using numerical methods. Monte Carlo integration procedure is especially useful to perform the calculations when complex probability functions are used. The methodology can be used for the direct determination of the efficiency and also for the calculation of corrections that require this determination of the efficiency, as it is the case of coincidence summing, geometric or self-attenuation corrections. In particular, we have applied the procedure to obtain some of the classical self-attenuation correction factors usually employed to correct for the sample attenuation of cylindrical geometry sources. The methodology clarifies the theoretical basis and approximations associated to each factor, by making explicit the probability which is generally hidden and implicit to each model. It has been shown that most of these self-attenuation correction factors can be derived by using a common underlying probability, having this probability a growing level of complexity as it reproduces more precisely the geometric and attenuation configuration of the source-detector system. Experimental verification of the improvement produced by increasing the model complexity has been performed by measuring samples spiked with certified nuclide activities with a HPGe detector. The methodology can be extended to obtain the theoretical efficiencies and corrections corresponding to any geometry by defining adequately the physical model and the subsequent probability corresponding to the particular studied situation.
引用
收藏
页码:31 / 39
页数:9
相关论文
共 9 条
  • [1] Determination of self-attenuation correction factor for lichen samples by using gamma-ray spectrometry
    Eke, C.
    Agar, O.
    Boztosun, I.
    Aslan, A.
    Emsen, B.
    KERNTECHNIK, 2017, 82 (01) : 136 - 139
  • [2] A revision factor to the Cutshall self-attenuation correction in 210Pb gamma-spectrometry measurements
    Jodlowski, Pawel
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 566 - 569
  • [3] Monte Carlo validation of the self-attenuation correction determination with the Cutshall transmission method in 210Pb measurements by gamma-spectrometry
    Jodlowski, Pawel
    Wachniew, Przemyslaw
    Chau Nguyen Dinh
    APPLIED RADIATION AND ISOTOPES, 2014, 87 : 387 - 389
  • [4] Self-attenuation correction factors for bioindicators measured by γ spectrometry for energies < 100 keV
    Manduci, L.
    Tenailleau, L.
    Trolet, J. L.
    De Vismes, A.
    Lopez, G.
    Piccione, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 613 (01) : 90 - 94
  • [5] Gamma-ray spectrometry for the self-attenuation correction factor of the sand samples from Antalya in Turkey
    Eke, Canel
    Boztosun, Ismail
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 301 (01) : 103 - 108
  • [6] Determination of the self-attenuation based on the sample composition in gamma-ray spectrometry of 210Pb: requirements for the scope of chemical analyses
    Jodlowski, Pawel
    Wachniew, Przemyslaw
    Nowak, Jakub
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 311 (02) : 1511 - 1516
  • [7] Theoretical and experimental estimation of self-attenuation corrections in determination of 210Pb by γ-spectrometry with well Ge detector
    Pilleyre, T
    Sanzelle, S
    Miallier, D
    Faïn, J
    Courtine, F
    RADIATION MEASUREMENTS, 2006, 41 (03) : 323 - 329
  • [8] Determination of the self-attenuation based on the sample composition in gamma-ray spectrometry of 210Pb: requirements for the scope of chemical analyses
    Paweł Jodłowski
    Przemysław Wachniew
    Jakub Nowak
    Journal of Radioanalytical and Nuclear Chemistry, 2017, 311 : 1511 - 1516
  • [9] Determination of gamma-ray self-attenuation correction in environmental samples by combining transmission measurements and Monte Carlo simulations
    Sostaric, Marko
    Babic, Dinko
    Petrinec, Branko
    Zgorelec, Zeljka
    APPLIED RADIATION AND ISOTOPES, 2016, 113 : 110 - 116