Line Current Differential Relay Operation Under Severe Current Transformer Saturation Conditions

被引:1
|
作者
Hedding, Roger A. [1 ]
Holst, Stig [2 ]
机构
[1] ABB Inc, Norwalk, CT 06851 USA
[2] ABB AB, Zurich, Switzerland
来源
2009 62ND ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS | 2009年
关键词
D O I
10.1109/CPRE.2009.4982517
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Relays rely on the current transformer to produce a secondary current that faithfully reflects the primary current for proper operation. In some instances this isn't the case. This paper will look at cases where severe ct saturation can be a problem, review the real time digital simulator inputs to the relay, and look at what mechanisms in modern line current differential relays are used to mitigate the problem.
引用
收藏
页码:256 / +
页数:2
相关论文
共 50 条
  • [1] Influence of current transformer saturation on line current differential protection algorithms
    Gangadharan, P. K.
    Sidhu, T. S.
    Klimek, A.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2007, 1 (02) : 270 - 277
  • [2] Compensation of the current transformer saturation effects for transmission line fault location with impedance-differential relay
    Herlender, J.
    Izykowski, J.
    Solak, K.
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 182
  • [3] An operation criterion for line current differential relay with higher sensitivity
    Wang, Haigang
    Dong, X. Z.
    Bo, Z. Q.
    Caunce, B. R. J.
    Klimek, A.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 2690 - 2695
  • [4] Transmission Line Distance Protection Under Current Transformer Saturation
    Zheng, Yuping
    Wu, Tonghua
    Hong, Feng
    Yao, Gang
    Chai, Jimin
    Wei, Zhinong
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2021, 9 (01) : 68 - 76
  • [5] Transmission Line Distance Protection Under Current Transformer Saturation
    Yuping Zheng
    Tonghua Wu
    Feng Hong
    Gang Yao
    Jimin Chai
    Zhinong Wei
    JournalofModernPowerSystemsandCleanEnergy, 2021, 9 (01) : 68 - 76
  • [6] Optimizing the operation of current differential protection by power differential relay for three phase transformer
    Bahmani, B
    Nafar, M
    Ranjbar, AM
    Proceedings of the 4th WSEAS International Conference on Applications of Electrical Engineering, 2005, : 378 - 383
  • [7] Restoration of the current transformer secondary current under core saturation conditions based on ANN
    Odinaev, Ismoil
    Abdel-Aty, Abdel-Haleem
    Pazderin, Andrey
    Safaraliev, Murodbek
    Matrenin, Pavel
    Senyuk, Mihail
    Menaem, Amir Abdel
    Kanan, Mohammad
    HELIYON, 2024, 10 (18)
  • [8] A New Approach to Current Transformer Saturation Compensation for Transmission Line Differential Protection
    Ebrahimian, Valiolah
    Namdari, Farhad
    Shakarami, Mahmoud-Reza
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2024,
  • [9] GSU Transformer - Current Transformer Connections and Differential Relay Applications
    Hansen, Daniel J.
    2014 67TH ANNUAL CONFERENCE FOR PROTECTIVE RELAY ENGINEERS, 2014, : 393 - 400
  • [10] The Impact of Current-Transformer Saturation on Transformer Differential Protection
    Stanbury, Michael
    Djekic, Zarko
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (03) : 1278 - 1287