Online prediction of mass flow rate of solids in dilute phase pneumatic conveying systems using multivariate calibration

被引:11
作者
Arakaki, Cecilia [1 ]
Ratnayake, Chandana [1 ]
Halstensen, Maths [2 ]
机构
[1] Telemark Technol R&D Ctr Tel Tek, Dept POSTEC, Porsgrunn, Norway
[2] TUC, Porsgrunn, Norway
关键词
Pneumatic conveying; Partial least squares; Mass flow rate; Dilute phase; Dextrose; Multivariate calibration; DENSE;
D O I
10.1016/j.powtec.2009.05.021
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Pneumatic conveying systems are used extensively in a wide range of industrial applications. Mass flow rate is one of the most important parameters in this kind of system since it is fundamental for the control of this process and to improve its operation efficiency. A method to predict the mass flow rate of solids in dilute phase conveying is presented in this article. The method uses pressure and air flow rate measurements as variables to calibrate a Partial Least Squares (PLS) regression model, which can be used to predict the mass flow rate of solids from new pressure and air flow rate measurements. Pneumatic conveying tests were carried out with dextrose monohydrate in dilute phase conditions. Independent experimental data from the tests was used to validate the model. The model was successfully validated for a range of different conditions of blow tank pressure and air flow rate. Good agreement with the experimental data was obtained when predicting mass flow rate with all the sensors available in the pneumatic conveying test rig. When using only the air flow rate measurements and two pressure sensors the accuracy of prediction was not affected. The latest suggests the possibility of industrial application. since air flow meters and pressure transmitters are commonly used in industrial settings. (c) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 19 条
[1]  
ARAKAKI C, 2007, BIOPOWDERS MIN RES I
[2]  
ARAKAKI C, 2006, 5 INT C CONV HANDL P
[3]  
CABREJOS FJ, 1992, ASME WINT ANN M
[4]   A pressure pulse method for monitoring flow rate in dense down flows of Geldart group B particles [J].
Davies, CE ;
Tallon, SJ .
POWDER TECHNOLOGY, 2004, 148 (2-3) :102-105
[5]  
*DEP TRAD IND, 2001, PULV FUEL PF FLOW ME
[6]  
Esbensen K.H., 2001, Multivariate Data Analysis - in practice. Number 1, V5
[7]   Online prediction of mass flow rate of solids in dense phase pneumatic conveying systems using multiple pressure transmitters and multivariate calibration [J].
Halstensen, Maths ;
Arakaki, Cecilia ;
Ratnayake, Chandana ;
Datta, Biplab K. .
POWDER TECHNOLOGY, 2009, 189 (03) :416-421
[8]  
Klinzing G.E., 2001, HANDB POWD TECHNOL, P291
[9]  
Martens H., 1989, MULTIVARIATE CALIBRA, P419, DOI 10.1002/bimj.4710330407
[10]   Plant tests of an on-line multiple-pipe pulverised coal mass flow measuring system [J].
Millen, MJ ;
Sowerby, BD ;
Coghill, PJ ;
Tickner, JR ;
Kingsley, R ;
Grima, C .
FLOW MEASUREMENT AND INSTRUMENTATION, 2000, 11 (03) :153-158