Sample bottle coated with sorbent as a novel solid-phase extraction device for rapid on-site detection of BTEX in water

被引:22
作者
Liu, Xiwen [1 ]
Hu, Qingkun [1 ]
Tong, Yuanjun [1 ]
Li, Nan [1 ]
Ouyang, Sai [2 ]
Yang, Huangsheng [1 ]
Xu, Jianqiao [1 ]
Ouyang, Gangfeng [1 ]
机构
[1] Sun Yat Sen Univ, Sch Chem, MOE Key Lab Bioinorgan & Synthet Chem, Guangzhou 510275, Guangdong, Peoples R China
[2] Hunan Inst & Technol, Sch Chem & Chem Engn, Key Lab Hunan Prov Adv Carbon based Funct Mat, Yueyang 414006, Hunan, Peoples R China
关键词
On-site detection; Solid-phase extraction; Field-portable gas chromatography-mass spectrometry; BTEX; CHROMATOGRAPHY-MASS SPECTROMETRY; VOLATILE ORGANIC-COMPOUNDS; GAS-CHROMATOGRAPHY; XYLENE ISOMERS; MICROEXTRACTION; ETHYLBENZENE; BENZENE; TOLUENE; GRAPHENE; FIBER;
D O I
10.1016/j.aca.2021.338226
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-phase extraction (SPE) is a popular technique for environmental sample pretreatment. However, SPE usually requires complex sample pretreatment processes, which is time-consuming and inconvenient for real-time and on-site monitoring. Herein, a solvent-free, rapid, and user-friendly SPE device was developed by coating the polydimethylsiloxane (PDMS)/divinylbenzene (DVB) sorbent on the inner wall of a sample bottle. The extraction process and desorption process were both carried out in the bottle. The analytes trapped in the sorbent were thermally desorbed and simultaneously sucked out from the bottle by an air sampling tube equipped on field-portable GC-MS. Different to previous work, the sample pretreatment process didn't require any complicated and time-consuming steps, such as centrifugation or filtration. The total analysis time for each sample was less than 25 min, which was feasible for rapid on-site detection, and thus avoided the losses and contamination of samples in conventional sample storage and transportation processes. Under optimal conditions, the proposed SPE method exhibited wide linear ranges, low detection limits (0.010-0.036 mu g L-1, which were much lower than the maximum levels restricted by the US Environmental Protection Agency and the Chinese GB3838-2002 standard), good intra-bottle repeatability (6.13-7.17%, n = 3) and satisfactory inter-bottle reproducibility (4.73-6.47%, n = 3). Finally, the method was successfully applied to the rapid detection of BTEX in the field. The recoveries of BTEX in spiked water samples ranged from 89.1% to 116.2%. This work presents a novel SPE approach for rapid on-site monitoring in water samples. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:8
相关论文
共 42 条
[21]   Evolution of solid-phase microextraction technology [J].
Lord, H ;
Pawliszyn, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 885 (1-2) :153-193
[22]   Ordered macro/micro-porous metal-organic framework of type ZIF-8 in a steel fiber as a sorbent for solid-phase microextraction of BTEX [J].
Maya, Fernando ;
Ghani, Milad .
MICROCHIMICA ACTA, 2019, 186 (07)
[23]   Application of porous membrane-protected chitosan microspheres to determine benzene, toluene, ethylbenzene, xylenes and styrene in water [J].
Naing, Nyi Nyi ;
Li, Sam Fong Yau ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2016, 1448 :42-48
[24]   Graphene oxide-based dispersive solid-phase extraction combined with in situ derivatization and gas chromatography-mass spectrometry for the determination of acidic pharmaceuticals in water [J].
Naing, Nyi Nyi ;
Li, Sam Fong Yau ;
Lee, Hian Kee .
JOURNAL OF CHROMATOGRAPHY A, 2015, 1426 :69-76
[25]   Micro-solid phase extraction of benzene, toluene, ethylbenzene and xylenes from aqueous solutions using water-insoluble β-cyclodextrin polymer as sorbent [J].
Nojavan, Saeed ;
Yazdanpanah, Mina .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1525 :51-59
[26]   An experimental design approach for the solid phase extraction of some organophosphorus pesticides from water samples with polymeric microbeads [J].
Ozer, Elif Tumay ;
Osman, Bilgen ;
Parlak, Buse .
MICROCHEMICAL JOURNAL, 2020, 154
[27]   Green solid-phase microextraction fiber coating based on the metal-organic framework CIM-80(Al): Analytical performance evaluation in direct immersion and headspace using gas chromatography and mass spectrometry for the analysis of water, urine and brewed coffee [J].
Pacheco-Fernandez, Idaira ;
Rentero, Manuel ;
Ayala, Juan H. ;
Pasan, Jorge ;
Pino, Veronica .
ANALYTICA CHIMICA ACTA, 2020, 1133 :137-149
[28]   Fast spark discharge-laser-induced breakdown spectroscopy method for rice botanic origin determination [J].
Perez-Rodriguez, Michael ;
Dirchwolf, Pamela Maia ;
Silva, Tiago Varao ;
Vieira, Alan Lima ;
Neto, Jose Anchieta Gomes ;
Pellerano, Roberto Gerardo ;
Ferreira, Edilene Cristina .
FOOD CHEMISTRY, 2020, 331
[29]   Human health risk assessment for exposure to BTEXN in an urban aquifer using deterministic and probabilistic methods: A case study of Chennai city, India [J].
Rajasekhar, Bokam ;
Nambi, Indumathi M. ;
Govindarajan, Suresh Kumar .
ENVIRONMENTAL POLLUTION, 2020, 265
[30]   Measurement of volatile organic compounds in sediments of the Scheldt Estuary and the Southern North Sea [J].
Roose, P ;
Dewulf, J ;
Brinkman, UAT ;
Van Langenhove, H .
WATER RESEARCH, 2001, 35 (06) :1478-1488