Sample bottle coated with sorbent as a novel solid-phase extraction device for rapid on-site detection of BTEX in water
被引:22
作者:
Liu, Xiwen
[1
]
Hu, Qingkun
[1
]
Tong, Yuanjun
[1
]
Li, Nan
[1
]
Ouyang, Sai
[2
]
Yang, Huangsheng
[1
]
Xu, Jianqiao
[1
]
Ouyang, Gangfeng
[1
]
机构:
[1] Sun Yat Sen Univ, Sch Chem, MOE Key Lab Bioinorgan & Synthet Chem, Guangzhou 510275, Guangdong, Peoples R China
[2] Hunan Inst & Technol, Sch Chem & Chem Engn, Key Lab Hunan Prov Adv Carbon based Funct Mat, Yueyang 414006, Hunan, Peoples R China
关键词:
On-site detection;
Solid-phase extraction;
Field-portable gas chromatography-mass spectrometry;
BTEX;
CHROMATOGRAPHY-MASS SPECTROMETRY;
VOLATILE ORGANIC-COMPOUNDS;
GAS-CHROMATOGRAPHY;
XYLENE ISOMERS;
MICROEXTRACTION;
ETHYLBENZENE;
BENZENE;
TOLUENE;
GRAPHENE;
FIBER;
D O I:
10.1016/j.aca.2021.338226
中图分类号:
O65 [分析化学];
学科分类号:
070302 ;
081704 ;
摘要:
Solid-phase extraction (SPE) is a popular technique for environmental sample pretreatment. However, SPE usually requires complex sample pretreatment processes, which is time-consuming and inconvenient for real-time and on-site monitoring. Herein, a solvent-free, rapid, and user-friendly SPE device was developed by coating the polydimethylsiloxane (PDMS)/divinylbenzene (DVB) sorbent on the inner wall of a sample bottle. The extraction process and desorption process were both carried out in the bottle. The analytes trapped in the sorbent were thermally desorbed and simultaneously sucked out from the bottle by an air sampling tube equipped on field-portable GC-MS. Different to previous work, the sample pretreatment process didn't require any complicated and time-consuming steps, such as centrifugation or filtration. The total analysis time for each sample was less than 25 min, which was feasible for rapid on-site detection, and thus avoided the losses and contamination of samples in conventional sample storage and transportation processes. Under optimal conditions, the proposed SPE method exhibited wide linear ranges, low detection limits (0.010-0.036 mu g L-1, which were much lower than the maximum levels restricted by the US Environmental Protection Agency and the Chinese GB3838-2002 standard), good intra-bottle repeatability (6.13-7.17%, n = 3) and satisfactory inter-bottle reproducibility (4.73-6.47%, n = 3). Finally, the method was successfully applied to the rapid detection of BTEX in the field. The recoveries of BTEX in spiked water samples ranged from 89.1% to 116.2%. This work presents a novel SPE approach for rapid on-site monitoring in water samples. (C) 2021 Elsevier B.V. All rights reserved.