Effect of recycling on the thermodynamic and thermoeconomic performances of SOFC based on trigeneration systems; A comparative study

被引:73
作者
Chitsaz, Ata [1 ]
Hosseinpour, Javad [2 ]
Assadi, Mohsen [3 ]
机构
[1] Urmia Univ, Fac Engn, Orumiyeh, Iran
[2] Univ Tabriz, Fac Mech Engn, Tabriz, Iran
[3] Univ Stavanger, Ctr Sustainable Energy Solut CENSE, N-4036 Stavanger, Norway
关键词
SOFC; Trigeneration; Recycling; GAX absorption refrigeration; Economic; Unit cost; OXIDE FUEL-CELL; ABSORPTION-REFRIGERATION CYCLE; OPTIMIZATION; GAX; ENERGY; PLANT;
D O I
10.1016/j.energy.2017.02.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, methane fed trigeneration systems producing power, cooling and heating by means of combination of SOFC, generator-absorber heat exchanger (GAX) absorption refrigeration and heat recovery systems are proposed. Accentuating on the gas recycle of anode and cathode of the SOFC stack, performance of four different suggested configurations are compared with each other. Thermodynamic model is developed for the proposed systems using the mass, energy and exergy balance equations. To give information about the viability of the systems, economic point of view is also taken into account. Meanwhile, the comparison is performed through parametric studies in which the effects of anode recycle and cathode recycle on the net electrical power, energy and exergy efficiency as well as on the unit product cost of trigeneration systems are investigated. The results show that the total energy efficiency of the trigeneration system with anode gas recycle (Tri-SOFC-AR) is 82.5% which is almost 6% larger than that of the simple base case system proposed (Tri-SOFC). In addition, results revealed that among the proposed systems, the one in which the anode and cathode gas recycle (Tri-SOFC-ACR) is used shows the highest exegetic and economic performance in comparison with the other configurations. (C) 2017 Published by Elsevier Ltd.
引用
收藏
页码:613 / 624
页数:12
相关论文
共 30 条
[1]   Performance comparison of three trigeneration systems using organic rankine cycles [J].
Al-Sulaiman, Fahad A. ;
Hamdullahpur, Feridun ;
Dincer, Ibrahim .
ENERGY, 2011, 36 (09) :5741-5754
[2]   Energy analysis of a trigeneration plant based on solid oxide fuel cell and organic Rankine cycle [J].
Al-Sulaiman, Fahad A. ;
Dincer, Ibrahim ;
Hamdullahpur, Feridun .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2010, 35 (10) :5104-5113
[3]   Exergy analysis of an integrated solid oxide fuel cell and organic Rankine cycle for cooling, heating and power production [J].
Al-Sulaiman, Fahad A. ;
Dincer, Ibrahim ;
Hamdullahpur, Feridun .
JOURNAL OF POWER SOURCES, 2010, 195 (08) :2346-2354
[4]  
Bejan A, 1996, Thermal Design and Optimization
[5]  
Bossel UG, 1992, FIN REP SOFC DAT FAC
[6]   Multi-criteria optimization of a district cogeneration plant integrating a solid oxide fuel cell-gas turbine combined cycle, heat pumps and chillers [J].
Burer, M ;
Tanaka, K ;
Favrat, D ;
Yamada, K .
ENERGY, 2003, 28 (06) :497-518
[7]   Single-level optimization of a hybrid SOFC-GT power plant [J].
Calise, F. ;
d'Accadia, M. Dentice ;
Vanoli, L. ;
von Spakovsky, M. R. .
JOURNAL OF POWER SOURCES, 2006, 159 (02) :1169-1185
[8]   Energy and exergy analysis of simple solid-oxide fuel-cell power systems [J].
Chan, SH ;
Low, CF ;
Ding, OL .
JOURNAL OF POWER SOURCES, 2002, 103 (02) :188-200
[9]   Greenhouse gas emission and exergy analyses of an integrated trigeneration system driven by a solid oxide fuel cell [J].
Chitsaz, Ata ;
Mahmoudi, S. Mohammad S. ;
Rosen, Marc A. .
APPLIED THERMAL ENGINEERING, 2015, 86 :81-90
[10]   Investigation on zero grid-electricity design strategies of solid oxide fuel cell trigeneration system for high-rise building in hot and humid climate [J].
Fong, K. F. ;
Lee, C. K. .
APPLIED ENERGY, 2014, 114 :426-433