Optimized dyeing conditions of immunoprotein with reactive dye Procion Blue MX-7RX

被引:9
作者
Wang, Shwu-Jinng
Lin, Hsiu-Min
Wang, Xin-Ren
Hsiung, Kuang-Pin
Liu, Yung-Chuan [1 ]
机构
[1] Natl Chung Hsing Univ, Dept Chem Engn, Taichung 402, Taiwan
[2] Taiwan Unison Biotech, Dept Res & Dev, Chunan 350, Taiwan
关键词
reactive dyes; immunochromatographic test; optimal reaction conditions; response surface methodology;
D O I
10.1016/j.ab.2006.11.026
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
For investigating the feasibility of using reactive dyes as an immunoassay marker, a dichlorine triazine dye, Procion Blue MX-7RX, was employed to stain the antibody against human serum albumin (anti-HSA). With the color intensity revealed in the immunochromatographic test strip as the objective variables, the optimal dyeing conditions were found as follows: pH 11.4, temperature 35.7 degrees C, molar ratio 188 (mol dye/mol antibody), and reaction time 45.6 min. The dyed-anti-HSA revealed a maximal color intensity of 8738 without apparent loss of antigen binding affinity. (c) 2006 Elsevier Inc. All rights reserved.
引用
收藏
页码:190 / 196
页数:7
相关论文
共 29 条
[1]   Development of a point-of-care assay system for high-sensitivity C-reactive protein in whole blood [J].
Ahn, JS ;
Choi, S ;
Jang, SH ;
Chang, HJ ;
Kim, JH ;
Nahm, KB ;
Oh, SW ;
Choi, EY .
CLINICA CHIMICA ACTA, 2003, 332 (1-2) :51-59
[2]   Development of a new immunosensor for pesticide detection: a disposable system with liposome-enhancement and amperometric detection [J].
Baumner, AJ ;
Schmid, RD .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (05) :519-529
[3]  
Box GEP, 1978, STAT EXPT
[4]   A rapid chromatographic strip test for the pen-side diagnosis of rinderpest virus [J].
Brüning, A ;
Bellamy, K ;
Talbot, D ;
Anderson, J .
JOURNAL OF VIROLOGICAL METHODS, 1999, 81 (1-2) :143-154
[5]  
CHANDLER J, 2001, IVD TECHNOL, V7, P34
[6]  
CHANDLER J, 2000, IVD TECHNOL, V6, P39
[7]   Colloidal gold-based immunochromatogrphic assay for detection of botulinum neurotoxin type B [J].
Chiao, DJ ;
Shyu, RH ;
Hu, CS ;
Chiang, HY ;
Tang, SS .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (01) :37-41
[8]   A rapid, simple measurement of human albumin in whole blood using a fluorescence immunoassay (I) [J].
Choi, S ;
Choi, EY ;
Kim, DJ ;
Kim, JH ;
Kim, TS ;
Oh, SW .
CLINICA CHIMICA ACTA, 2004, 339 (1-2) :147-156
[9]   Rapid and simple quantitative measurement of α-fetoprotein by combining immunochromatographic strip test and artificial neural network image analysis system [J].
Chuang, L ;
Hwang, JY ;
Chang, HC ;
Chang, FM ;
Jong, SB .
CLINICA CHIMICA ACTA, 2004, 348 (1-2) :87-93
[10]   Differences in urinary albumin detected by four immunoassays and high-performance liquid chromatography [J].
Comper, WD ;
Jerums, G ;
Osicka, TM .
CLINICAL BIOCHEMISTRY, 2004, 37 (02) :105-111