A randomized prospective long-term study of two oral appliances for sleep apnoea treatment

被引:66
作者
Ghazal, Akssam [1 ]
Sorichter, Stefan [2 ]
Jonas, Irmtrud [1 ]
Rose, Edmund C. [1 ]
机构
[1] Univ Freiburg, Dept Orthodont, D-79106 Freiburg, Germany
[2] Dept Pulm Dis, Sleep Lab, Freiburg, Germany
关键词
mandibular advancement devices; obstructive sleep apnoea; oral appliances; sleep apnoea syndrome; sleep-disordered breathing; POSITIVE AIRWAY PRESSURE; CONTROLLED CROSSOVER TRIAL; EFFICACY;
D O I
10.1111/j.1365-2869.2009.00738.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Various types of mandibular protrusive appliances have revealed different treatment success in mild-to-moderate obstructive sleep apnoea (OSA). The present study compared the long-term effect of two different appliances in the treatment of OSA. A total of 103 patients with OSA were randomized and treated with an IST (R) or Thornton Anterior Positioner (TAP((TM))) appliance. They were followed-up after a short-term treatment period of 6 months and long-term treatment period of over 24 months. Sleep studies in the sleep laboratory were conducted with and without the appliances, and various questionnaires assessing subjective daytime sleepiness, sleep quality, quality of life and symptom scores were administered at each time interval. Quality of life, sleep quality, sleepiness, symptoms and sleep outcome showed significant improvement in the short-term evaluation with both appliances, but the TAP((TM)) appliance revealed a significantly greater effect. After more than 2 years of treatment, sleep outcomes revealed an equal effect with both appliances. The subjective benefits achieved initially lessened significantly. This study illustrates that both the IST (R) and the TAP((TM)) appliances are effective therapeutic devices for OSA after a period of over 24 months. Lack of compliance may be due to insufficient improvement in anticipated subjective symptoms and/or a recurrence of symptoms over time.
引用
收藏
页码:321 / 328
页数:8
相关论文
共 22 条
[1]  
[Anonymous], 2006, COCHRANE DB SYST REV, DOI DOI 10.1002/14651858
[2]   Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea [J].
Barnes, M ;
McEvoy, RD ;
Banks, S ;
Tarquinio, N ;
Murray, CG ;
Vowles, N ;
Pierce, RJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 170 (06) :656-664
[3]   A Randomized controlled trial of continuous positive airway pressure in mild obstructive sleep apnea [J].
Barnes, M ;
Houston, D ;
Worsnop, CJ ;
Neill, AM ;
Mykytyn, IJ ;
Kay, A ;
Trinder, J ;
Saunders, NA ;
McEvoy, RD ;
Pierce, RJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (06) :773-780
[4]   German version of the Epworth Sleepiness Scale [J].
Bloch, KE ;
Schoch, OD ;
Zhang, JNN ;
Russi, EW .
RESPIRATION, 1999, 66 (05) :440-447
[5]   A randomized, controlled crossover trial of two oral appliances for sleep apnea treatment [J].
Bloch, KE ;
Iseli, A ;
Zhang, JN ;
Xie, XB ;
Kaplan, V ;
Stoeckli, PW ;
Russi, EW .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 162 (01) :246-251
[6]   THE PITTSBURGH SLEEP QUALITY INDEX - A NEW INSTRUMENT FOR PSYCHIATRIC PRACTICE AND RESEARCH [J].
BUYSSE, DJ ;
REYNOLDS, CF ;
MONK, TH ;
BERMAN, SR ;
KUPFER, DJ .
PSYCHIATRY RESEARCH, 1989, 28 (02) :193-213
[7]  
Clark G T, 1998, Sleep Med Rev, V2, P163, DOI 10.1016/S1087-0792(98)90019-3
[8]   A crossover study comparing the efficacy of continuous positive airway pressure with anterior mandibular positioning devices on patients with obstructive sleep apnea [J].
Clark, GT ;
Blumenfeld, I ;
Yoffe, N ;
Peled, E ;
Lavie, P .
CHEST, 1996, 109 (06) :1477-1483
[9]  
de Almeida FR, 2005, J CLIN SLEEP MED, V1, P143
[10]   Randomized placebo-controlled crossover trial of continuous positive airway pressure for mild sleep apnea/hypopnea syndrome [J].
Engleman, HM ;
Kingshott, RN ;
Wraith, PK ;
Mackay, TW ;
Deary, IJ ;
Douglas, NJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (02) :461-467