Effect of 30% oxygen administration on verbal cognitive performance, blood oxygen saturation and heart rate

被引:25
作者
Chung, Soon-Cheol
Iwaki, Sunao
Tack, Gye-Rae
Yi, Jeong-Han
You, Ji-Hye
Kwon, Ji-Hun
机构
[1] Konkuk Univ, Dept Biomed Engn, Chungju 380701, Chungbuk, South Korea
[2] AIST, Natl Inst Adv Ind Sci & Technol, Inst Human Sci & Bimed Engn, Ikeda, Osaka 5638577, Japan
关键词
30% oxygen administration; verbal cognitive performance; blood oxygen saturation; heart rate;
D O I
10.1007/s10484-006-9023-5
中图分类号
B849 [应用心理学];
学科分类号
040203 ;
摘要
This study investigated the effect of 30% oxygen administration on verbal cognitive performance, blood oxygen saturation, and heart rate. Five male (24.6(+/- 0.9) years) and five female (22.2(+/- 1.9) years) college students were selected as the subjects for this study. Two psychological tests were developed to measure the performance level of verbal cognition. The experiment consisted of two runs: one was a verbal cognition task, with normal air (21% oxygen) administered and the other was with hyperoxic air (30% oxygen) administered. The experimental sequence in each run consisted of Rest 1 (1 min), Control (1 min), Task (4 min), and Rest 2 (4 min). Blood oxygen saturation and heart rate were measured throughout the four phases. The results of the verbal behavioural analysis reveal that accuracy rates were enhanced with 30% oxygen administration compared to 21% oxygen. When 30% oxygen was supplied, blood oxygen saturation was increased significantly compared to that with 21% oxygen administration, whereas heart rate showed no significant difference. Significant positive correlations were found between changes in oxygen saturation and cognitive performance. This result supports the hypothesis that 30% oxygen administration would lead to increases in verbal cognitive performance.
引用
收藏
页码:281 / 292
页数:12
相关论文
共 50 条
[31]   Design of an Instrument for Measuring Heart Rate and Blood Oxygen Based on Arduino [J].
Dai, Fengzhi ;
Wen, Haokang ;
Zhao, Jichao ;
Hao, Hongbo ;
Zhang, Qianqian .
JOURNAL OF ROBOTICS NETWORKING AND ARTIFICIAL LIFE, 2021, 7 (04) :275-278
[32]   Resuscitation of the critically ill in the ED: Responses of blood pressure, heart rate, shock index, central venous oxygen saturation, and lactate [J].
Rady, MY ;
Rivers, EP ;
Nowak, RM .
AMERICAN JOURNAL OF EMERGENCY MEDICINE, 1996, 14 (02) :218-225
[33]   Aging-related changes in the blood flow rate and oxygen saturation of the blood in the cerebral cortex of rats [J].
Sokolova I.B. ;
Puzanov M.V. ;
Melnykova N.N. ;
Mourovets V.O. ;
Sergeev I.V. ;
Dvoretsky D.P. .
Advances in Gerontology, 2016, 6 (1) :47-51
[34]   Effects of hyperoxic air on simple visual matching task performance and blood oxygen saturation of ADHD children [J].
Choi, Mi-Hyun ;
Kim, Hyun-Joo ;
Chung, Young-Sun ;
Chung, Soon-Cheol .
HEALTHMED, 2012, 6 (09) :3008-3011
[35]   The Accuracy of Pulse Oxygen Saturation, Heart Rate, BloodPressure, and Respiratory Rate Raised by a ContactlessTelehealth Portal:Validation Study [J].
Dcruz, Julian Gerald ;
Yeh, Paichang .
JMIR FORMATIVE RESEARCH, 2024, 8
[36]   Evaluation of a Camera-Based Monitoring Solution Against Regulated Medical Devices to Measure Heart Rate, Respiratory Rate, Oxygen Saturation, and Blood Pressure [J].
Talukdar, Debjyoti ;
De Deus, Luis Felipe ;
Sehgal, Nikhil .
CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
[37]   HEART RATE AND OXYGEN SATURATION ESTIMATION FROM FACIAL VIDEO WITH MULTIMODAL PHYSIOLOGICAL DATA GENERATION [J].
Akamatsu, Yusuke ;
Onishi, Yoshifumi ;
Imaoka, Hitoshi .
2022 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2022, :1111-1115
[38]   IoT Health Monitoring Device of Oxygen Saturation (SpO2) and Heart Rate Level [J].
Tham, O. Y. ;
Markom, M. A. ;
Abu Bakar, A. H. ;
Tan, E. S. Mohd Muslim ;
Markom, A. M. .
2020 1ST INTERNATIONAL CONFERENCE ON INFORMATION TECHNOLOGY, ADVANCED MECHANICAL AND ELECTRICAL ENGINEERING (ICITAMEE 2020), 2020, :128-133
[39]   Comparison of massage and prone position on heart rate and blood oxygen saturation level in preterm neonates hospitalized in neonatal intensive care units [J].
Hanan Mostafa El-sayd ;
Ghada Mohamed El-Mashad ;
Mohamed Zakaria Elsaied Mohamed ;
Zeinab Sabri Abouzouna .
Egyptian Pediatric Association Gazette, 71
[40]   Pethidine for labor analgesia; monitoring of newborn heart rate, blood pressure and oxygen saturation during the first 24 hours after the delivery [J].
Konefal, Halina ;
Jaskot, Brygida ;
Czeszynska, Maria Beata .
GINEKOLOGIA POLSKA, 2012, 83 (05) :357-362