Polyglycolide bioabsorbable screws in the treatment of ankle fractures

被引:43
作者
Hovis, WD [1 ]
Bucholz, RW [1 ]
机构
[1] UNIV TEXAS,SW MED SCH,DEPT ORTHOPAED SURG,DALLAS,TX 75235
关键词
D O I
10.1177/107110079701800303
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Twenty-one patients with unstable medial malleolar, bimalleolar, or trimalleolar ankle fractures underwent open reduction and internal fixation of the medial malleolus with 4.5-mm polyglycolide screws, All lateral malleolar fractures were internally fixed with standard metallic implants, Radiographic and clinical follow-up results were available on 16 of 21 patients, All fractures healed at an average of 3.4 months (range, 3-6 months), and there were no medial wound infections, Eight of 16 patients developed an inflammatory reaction to the biodegradable polyester at 3 to 4 months after implantation, including one who developed a sterile draining sinus tract. No surgical or nonsurgical treatment was required in those eight patients. We conclude that whereas polyester screws yield union rates and functional results similar to those of metallic screws in the treatment of medial malleolar fractures, the use of polyglycolide screws is associated with an unacceptable rate of inflammatory reactions.
引用
收藏
页码:128 / 131
页数:4
相关论文
共 12 条
[1]  
BLASIER RD, 1996, INSTR COURSE LECT, V174
[2]   DEGRADATION AND TISSUE REPLACEMENT OF AN ABSORBABLE POLYGLYCOLIDE SCREW IN THE FIXATION OF RABBIT FEMORAL OSTEOTOMIES [J].
BOSTMAN, O ;
PAIVARINTA, U ;
PARTIO, E ;
VASENIUS, J ;
MANNINEN, M ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1021-1031
[3]   BIODEGRADABLE INTERNAL-FIXATION FOR MALLEOLAR FRACTURES - A PROSPECTIVE RANDOMIZED TRIAL [J].
BOSTMAN, O ;
VAINIONPAA, S ;
HIRVENSALO, E ;
MAKELA, A ;
VIHTONEN, K ;
TORMALA, P ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (04) :615-619
[4]   FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS [J].
BOSTMAN, O ;
HIRVENSALO, E ;
MAKINEN, J ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :592-596
[5]  
BOSTMAN O, 1989, CLIN ORTHOPAEDICS, V238, P195
[6]   OSTEOLYTIC CHANGES ACCOMPANYING DEGRADATION OF ABSORBABLE FRACTURE FIXATION IMPLANTS [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1991, 73 (04) :679-682
[7]   ABSORBABLE IMPLANTS FOR THE FIXATION OF FRACTURES [J].
BOSTMAN, OM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :148-153
[8]   FIXATION WITH BIOABSORBABLE SCREWS FOR THE TREATMENT OF FRACTURES OF THE ANKLE [J].
BUCHOLZ, RW ;
HENRY, S ;
HENLEY, MB .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (03) :319-324
[9]  
Muller M, 1979, TECHNIQUES RECOMMEND
[10]  
ROCKWOOD CA, 1991, ROCKWOOD GREENS FRAC, V2