Performance analysis of an open absorption heat pump and thermal desalination system for heat and water recovery of coal-fired flue gas based on zero liquid discharge

被引:9
作者
Xue, Yuan [1 ]
Zhao, Bohan [1 ]
Wang, Sijiao [1 ]
Yin, Peili [1 ]
Wang, Hongxi [1 ]
机构
[1] Xian Technol Univ, Sch Mechatron Engn, Xian 710021, Peoples R China
关键词
Zero liquid discharge; Open absorption heat pump; Thermal desalination; Heat and water recovery; WASTE HEAT; LATENT-HEAT; DRIVEN; EVAPORATION; EXERGY;
D O I
10.1016/j.enconman.2022.116379
中图分类号
O414.1 [热力学];
学科分类号
摘要
An innovative combined system based on an open absorption heat pump and low-temperature multi-effect desalination system is proposed to provide fresh water and domestic hot water in order to achieve zero liquid discharge from coal-fired power plants and recover the waste heat of flue gas. This system takes into consid-eration the evaporation of desulfurization wastewater by flue gas. By using a 600 MW unit as an example, energy and exergy analysis is used to examine the impacts of flue gas humidity, temperature, mass, generator pressure, solution concentration, and boiler load on system performance. The findings showed that because coal-fired power plants produce a significant amount of dry flue gas, an increase in gas humidity has little effect on product supply. As a result, little variation in the combined system is caused by the desulfurization wastewater spray evaporation, which allows power plants to achieve zero liquid discharge with only a small loss in exergy efficiency of about 6%. The recovery of sensible heat rather than latent heat benefits from an increase in the bulk of dry flue gas. The recovery of heat and water benefits more from an increase in operating load or flue gas temperature than the open absorption heat pump system itself. The generator pressure and rich solution con-centration have negligible effects on heat and water recovery. The open absorption heat pump system's increasing exergy efficiency trend and the boiler operating loads are also related. The exergy efficiency of the generator is the highest by about 75%, that of the desalination system is the lowest by about 29%, and the exergy destruction of the absorber is the highest by about 43%. The findings are likewise applicable to coal-fired power stations with various levels of electrical output.
引用
收藏
页数:9
相关论文
共 28 条
[1]  
[Anonymous], 2021, BP Statistical Review of World Energy
[2]   A novel technical route based on wet flue gas desulfurization process for flue gas dehumidification, water and heat recovery [J].
Chen, Zhen ;
You, Changfu ;
Wang, Haiming ;
Xie, Ning .
APPLIED THERMAL ENGINEERING, 2020, 171
[3]   A novel study of using oil refinery plants waste gases for thermal desalination and electric power generation: Energy, exergy & cost evaluations [J].
Eldean, Mohamed A. Sharaf ;
Soliman, A. M. .
APPLIED ENERGY, 2017, 195 :453-477
[4]   Parameter analysis of atomized droplets sprayed evaporation in flue gas flow [J].
Feng, Shuqin ;
Xiao, Liehui ;
Ge, Zhihua ;
Yang, Lijun ;
Du, Xiaoze ;
Wu, Hongwei .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 129 :936-952
[5]   Design methodology and multi-objective optimization of small-scale power-water production based on integration of Stirling engine and multi-effect evaporation desalination system [J].
Karambasti, Bahram Mahjoob ;
Ghodrat, Maryam ;
Ghorbani, Ghadir ;
Lalbakhsh, Ali ;
Behnia, Masud .
DESALINATION, 2022, 526
[6]   Recent advances in flue gas desulfurization gypsum processes and applications - A review [J].
Koralegedara, Nadeesha H. ;
Pinto, Patricio X. ;
Dionysiou, Dionysios D. ;
Al-Abed, Souhail R. .
JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2019, 251
[7]   SORPTION DEHUMIDIFICATION OF NATURAL-GAS EXHAUST [J].
LAZZARIN, RM ;
LONGO, GA ;
PICCININNI, F .
HEAT RECOVERY SYSTEMS & CHP, 1992, 12 (05) :385-389
[8]   Method of flash evaporation and condensation - heat pump for deep cooling of coal-fired power plant flue gas: Latent heat and water recovery [J].
Li, Yuzhong ;
Yan, Min ;
Zhang, Liqiang ;
Chen, Guifang ;
Cui, Lin ;
Song, Zhanlong ;
Chang, Jingcai ;
Ma, Chunyuan .
APPLIED ENERGY, 2016, 172 :107-117
[9]   Mass transfer performance comparison of two commonly used liquid desiccants: LiBr and LiCl aqueous solutions [J].
Liu, X. H. ;
Yi, X. Q. ;
Jiang, Y. .
ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (01) :180-190
[10]  
Manu S., 2016, International Journal of Sustainable Built Environment, V5, P370, DOI 10.1016/j.ijsbe.2016.08.002