Three-dimensional relationship between high-order root-mean-square wavefront error, pupil diameter, and aging

被引:112
作者
Applegate, Raymond A. [1 ]
Donnelly, William J., III
Marsack, Jason D.
Koenig, Darren E.
Pesudovs, Konrad
机构
[1] Univ Houston, Coll Optometry, Visual Opt Inst, Houston, TX 77204 USA
[2] Flinders Med Ctr, Dept Ophthalmol, Natl Hlth & Med Res Council, Ctr Clin Eye Res, Bedford Pk, SA 5042, Australia
[3] Flinders Univ S Australia, Bedford Pk, SA 5042, Australia
关键词
D O I
10.1364/JOSAA.24.000578
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report root-mean-square (RMS) wavefront error (WFE) for individual aberrations and cumulative high-order (HO) RMS WFE for the normal human eye as a function of age by decade and pupil diameter in 1 mm steps from 3 to 7 mm and determine the relationship among HO RMS WFE, mean age for each decade of life, and luminance for physiologic pupil diameters. Subjects included 146 healthy individuals from 20 to 80 years of age. Ocular aberration was measured on the preferred eye of each subject (for a total of 146 eyes through dilated pupils; computed for 3, 4, 5, 6, and 7 mm. pupils; and described with a tenth-radial-order normalized Zernike expansion. We found that HO RMS WFE increases faster with increasing pupil diameter for any given age and pupil diameter than it does with increasing age alone. A planar function accounts for 99% of the variance in the 3-D space defined by mean log HO RMS WFE, mean age for each decade of life, and pupil diameter. When physiologic pupil diameters are used to estimate HO RMS VFE as a function of luminance and age, at low luminance (9 cd/m(2)) HO RMS WFE decreases with increasing age. This normative data set details (1) the 3-D relationship between HO RMS WFE and age for fixed pupil diameters and (2) the 3-D relationship among HO RMS WFE, age, and luminance for physiologic pupil diameters. (c) 2007 Optical Society of America.
引用
收藏
页码:578 / 587
页数:10
相关论文
共 54 条
  • [1] Crystalline lens optical dysfunction through aging
    Alió, JL
    Schimchak, P
    Negri, HP
    Montés-Micó, R
    [J]. OPHTHALMOLOGY, 2005, 112 (11) : 2022 - 2029
  • [2] Interaction between aberrations to improve or reduce visual performance
    Applegate, RA
    Marsack, JD
    Ramos, R
    Sarver, EJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (08) : 1487 - 1495
  • [3] Metrics of retinal image quality predict visual performance in eyes with 20/17 or better visual acuity
    Applegate, Raymond A.
    Marsack, Jason D.
    Thibos, Larry N.
    [J]. OPTOMETRY AND VISION SCIENCE, 2006, 83 (09) : 635 - 640
  • [4] The human eye is an example of robust optical design
    Artal, P
    Benito, A
    Tabernero, J
    [J]. JOURNAL OF VISION, 2006, 6 (01): : 1 - 7
  • [5] Contribution of the cornea and internal surfaces to the change of ocular aberrations with age
    Artal, P
    Berrio, E
    Guirao, A
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2002, 19 (01): : 137 - 143
  • [6] EFFECTS OF AGING IN RETINAL IMAGE QUALITY
    ARTAL, P
    FERRO, M
    MIRANDA, I
    NAVARRO, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1993, 10 (07): : 1656 - 1662
  • [7] MONOCHROMATIC MODULATION TRANSFER-FUNCTION OF THE HUMAN EYE FOR DIFFERENT PUPIL DIAMETERS - AN ANALYTICAL EXPRESSION
    ARTAL, P
    NAVARRO, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (01): : 246 - 249
  • [8] Effect of aging on the monochromatic aberrations of the human eye
    Calver, RI
    Cox, MJ
    Elliott, DB
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1999, 16 (09): : 2069 - 2078
  • [9] Measurement of the spatial shift of the pupil center
    Camellin, M
    Gambino, F
    Casaro, S
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) : 1719 - 1721
  • [10] Matrix method to find a new set of Zernike coefficients from an original set when the aperture radius is changed
    Campbell, CE
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2003, 20 (02): : 209 - 217