Removing power line noise from recorded EMG

被引:0
作者
Mewett, DT [1 ]
Nazeran, H [1 ]
Reynolds, KJ [1 ]
机构
[1] Flinders Univ S Australia, Sch Informat & Engn, Adelaide, SA 5001, Australia
来源
PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE | 2001年 / 23卷
关键词
EMG; signal processing; digital filtering;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Three methods for offline removal of power line interference (hum) from electromyograms (EMGs) were compared using both simulated and recorded EMG signals. The first method was a simple recursive digital notch filter. In the second method (Regression-Subtraction), the amplitude and phase of the interference were estimated by regressing sine and cosine functions onto a 'quiet period' before the start of the muscular contraction. A sinusoid with this frequency, magnitude and phase was then subtracted from the entire length of the signal. In the third method (Spectrum Interpolation), it was assumed that the magnitude of the original component of the signal at the frequency of the interference can be approximated by interpolating between the adjacent frequency bins in the power spectrum. While Regression-Subtraction was found to give the highest SNR for the output signal under ideal conditions, Spectrum Interpolation was found to be comparable if the phase of the interference was not constant and superior if the interference contained strong harmonic components.
引用
收藏
页码:2190 / 2193
页数:4
相关论文
共 5 条
[1]   Methods to reduce the variability of EMG power spectrum estimates [J].
Baratta, RV ;
Solomonow, M ;
Zhou, BH ;
Zhu, M .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (05) :279-285
[2]  
Basmajian JV, 1985, MUSCLES ALIVE THEIR, P59
[3]   THE MODIFIED YULE-WALKER METHOD OF ARMA SPECTRAL ESTIMATION [J].
FRIEDLANDER, B ;
PORAT, B .
IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1984, 20 (02) :158-173
[4]   Estimation of surface electromyogram spectral alteration using reduced-order autoregressive model [J].
Karlsson, S ;
Yu, J .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) :520-527
[5]  
MEWETT DT, 2000, P IEEE EMBS APCBME, V2, P141