Brachytherapy dosimetry parameters calculated for a 131Cs source

被引:75
作者
Rivard, Mark J. [1 ]
机构
[1] Tufts Univ, Sch Med, New England Med Ctr, Dept Radiat Oncol, Boston, MA 02111 USA
关键词
Monte Carlo calculations; brachytherapy dosimetry; TG-43; MCNP; Cs-131;
D O I
10.1118/1.2432162
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A comprehensive analysis of the IsoRay Medical model CS-I Rev2 Cs-131 brachytherapy source was performed. Dose distributions were simulated using Monte Carlo methods (MCNP5) in liquid water, Solid Water (TM), and Virtual Water (TM) spherical phantoms. From these results, the in-water brachytherapy dosimetry parameters have been determined, and were compared with those of Murphy et al. [Med. Phys. 31, 1529-1538 (2004)] using measurements and simulations. Our results suggest that calculations obtained using erroneous cross-section libraries should be discarded as recommended by the 2004 AAPM TG-43U1 report. Our (MC)Lambda value of 1.046 +/- 0.019 cGy h(-1) U-1 is within 1.3% of that measured by Chen et al. [Med. Phys. 32, 3279-3285 (2005)] using TLDs and the calculated results of Wittman and Fisher [Med. Phys. 34, 49-54 (2007)] using MCNP5. Using the discretized energy approach of Rivard [Appl. Radiat. Isot. 55, 775-782 (2001)] to ascertain the impact of individual Cs-131 photons on radial dose function and anisotropy functions, there was virtual equivalence of results for 29.461 <= E-gamma <= 34.419 keV and for a mono-energetic 30.384 keV photon source. Comparisons of radial dose function and 2D anisotropy function data are also included, and an analysis of material composition and cross-section libraries was performed. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:754 / 762
页数:9
相关论文
共 28 条
  • [1] Dose rate constant of a Cesium-131 interstitial brachytherapy seed measured by thermoluminescent dosimetry and gamma-ray spectrometry
    Chen, Z
    Bongiorni, P
    Nath, R
    [J]. MEDICAL PHYSICS, 2005, 32 (11) : 3279 - 3285
  • [2] CULLEN DE, 1997, UCRL50400 L LIV NAT, V6
  • [3] An analysis of MCNP cross-sections and tally methods for low-energy photon emitters
    DeMarco, JJ
    Wallace, RE
    Boedeker, K
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (08) : 1321 - 1332
  • [4] Improved radial dose function estimation using current version MCNP Monte-Carlo simulation:: Model 6711 and ISC3500125I brachytherapy sources
    Duggan, DM
    [J]. APPLIED RADIATION AND ISOTOPES, 2004, 61 (06) : 1443 - 1450
  • [5] Monte Carlo-aided dosimetry of the symmetra model I25,S06 125I, interstitial brachytherapy seed
    Hedtjärn, H
    Carlsson, GA
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2000, 27 (05) : 1076 - 1085
  • [6] Monte Carlo-aided dosimetry of the Source Tech Medical Model STM1251 I-125 interstitial brachytherapy source
    Kirov, AS
    Williamson, JF
    [J]. MEDICAL PHYSICS, 2001, 28 (05) : 764 - 772
  • [7] Updated Solid Water™ to water conversion factors for 125I and 103Pd brachytherapy sources
    Meigooni, Ali S.
    Awan, Shahid B.
    Thompson, Nathan S.
    Dini, Sharifeh A.
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 3988 - 3992
  • [8] Dosimetric characteristics of the InterSource103 palladium brachytherapy source
    Meigooni, AS
    Sowards, K
    Soldano, M
    [J]. MEDICAL PHYSICS, 2000, 27 (05) : 1093 - 1100
  • [9] A COMPARISON OF SOLID PHANTOMS WITH WATER FOR DOSIMETRY OF I125 BRACHYTHERAPY SOURCES
    MEIGOONI, AS
    MELI, JA
    NATH, R
    [J]. MEDICAL PHYSICS, 1988, 15 (05) : 695 - 701
  • [10] Dosimetric characteristics of the Best® double-wall 103Pd brachytherapy source
    Meigooni, AS
    Bharucha, Z
    Yoe-Sein, M
    Sowards, K
    [J]. MEDICAL PHYSICS, 2001, 28 (12) : 2568 - 2575